Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 61 for “"transducer array"”.
-
Surface-micromachined Optical Ultrasound Transducer Array for 3D Photoacoustic Computed Tomography
… resolution. In contrast, optical ultrasound transducers (OUTs) have been investigated for PACT, owing to their size-independent sensitivity and simplicity of interfacing. However, fabrication defects and material failure oftentimes lead to low uniformity and stability of the OUTs, challenging …
-
Surface-micromachined Optical Ultrasound Transducer Array for 3D Photoacoustic Computed Tomography
… resolution. In contrast, optical ultrasound transducers (OUTs) have been investigated for PACT, owing to their size-independent sensitivity and simplicity of interfacing. However, fabrication defects and material failure oftentimes lead to low uniformity and stability of the OUTs, challenging …
-
Modeling of acoustic liquid manipulation generated by a phased transducer array
… of these applications have made use of phased arrays which incorporate many transducers which run at a single frequency but whose amplitudes and/or phases can be independently controlled. Though substantial work has been done in experimentally verifying the capabilities of this technique, a …
-
Development of MRI-compatible Transducer Array for Focused Ultrasound Surgery: : The Use of Relaxor-based Piezocrystals
… limited availability of experimental ultrasound array sources and multichannel electronics able to drive them hinder the research into FUS system configurations for patient conditions such as breast cancer. <br/>The work in this dissertation explored the development of ultrasound arrays for MRI …
-
A time-multiplex switching system for visual display of the outputs of an ultra-sonic transducer array
… the output signals from an ultrasonic transducer array for the visual display of an acoustic image by intensity modulation of a cathode ray tube is presented. Considerations pertinent to the design of an all solid-state analog switching system are discussed and the design of a …
-
Micromachined Scanning Devices for 3D Acoustic Imaging
… To conduct 3D ultrasound imaging, 2D ultrasound transducer arrays followed by multi-channel high-frequency data acquisition (DAQ) systems are frequently used. However, as the quantity and density of the transducer elements and also the DAQ channels increase, the acoustic imaging system becomes …
-
Efficient similarity-driven emission angle selection for coherent plane-wave compounding
… pulses emitted at different angles by a linear transducer array, 2) sampling the returning echo signals, after each plane-wave emission, with the same transducer array, 3) beamforming the recorded angle-specific raw data frames, and 4) compounding the beamformed data frames over all angles to …
-
Novel Polymer Transparent Ultrasound Transducers for Photoacoustic Imaging Applications
… to be detected by a single-element ultrasound transducer or a transducer array. However, one fundamental issue in current photoacoustic imaging system design is the opaque structure of the ultrasound transducer, which prevents effective and efficient light delivery onto the imaging target and …
-
Photoacoustic Microscopy and Photoacoustic Computed Tomography Using High-frequency Linear Array Ultrasonic Transducers
… imaging depth in tissue by employing ultrasonic array detectors and inverse algorithms. This dissertation aims to improve the functionality of OR-PAM using a high-frequency linear ultrasonic array, and to advance the performance of linear-array PACT to full view angle capability and higher …
-
An electro-mechanical acoustic imaging scanner assembly.
… assembly -utilizes a sixteen element linear transducer array mounted on the radius of an eight inch diameter circle at the focal plane of an acoustic lens. The line array is rotated at a constant speed of 400 RPM. Acoustic signals at 250 KHZ of approximately 26 db re 1 ubar at the transducers …
-
Electronics design for high density CMUT array based ultrasound imaging system
… real-time imaging data from a large number of transducer array elements is extremely challenging with the standard interconnect and transducer technology as there is a restriction on cable count due to the diameter of the catheter. Intracardiac Echocardiography (ICE) imaging systems require …
-
Facilitating detection and sizing of crack defects in pipes by 3D K-means clustering
… ultrasound data (obtained from a moving transducer array inside a pipe) to identify distinct clusters, effectively reducing noise and isolating critical crack-related features. Experimental validation has been performed on three pipe samples with different crack sizes and locations. The …
-
Structural Health Monitoring for Small Diameter Pipes with Guided Ultrasonic Wave
… Measurements are acquired by our innovative dual transducer array design and are processed with the Multiple Signal Classification (MUSIC) signal processing method. The defect position is predicated accurately and efficiently, which is very adaptive for SHM over long pipes. However, it fails to …
-
Signal acquisition and processing for autonomous Space Shuttle Cargo Bay acoustic measurements (NASA G-313)
A narrowband trigonal acoustic transducer array and digital signal processing software are described in support of Space Shuttle Vibroacoustic experiment [NASA G-313]. The three co-planar, vibrationally isolated pressure-sensing microphones, the preamplifiers and the filters are designed to meet …
-
A solid-state ultrasonic image converter
… optical means. Electronic scanning of a mosaic transducer at the focal plane of an acoustic lens enables target image reproduction on a cathode ray tube using intensity modulation. Previous work in developing the required amplifier and gating circuitry has resulted in systems with excessive …
-
Ultrasonic technique for chemical process control
… (HIFU) and has translated these into ultrasonic transducers for use in an industrial process control system. Traditional ultrasound monitoring techniques are based on operation in the linear domain and are used to monitor chemical processes by measurement of material acoustic velocity, …
-
Planar beam-steered acousto-optic light deflectors
… interdigital surface acoustic wave (SAW) transducers, anisotropic diffraction of acoustic waves and the rigorous theory of the interaction between guided optical waves and high frequency surface acoustic waves. The experiments were carried out on nickel indiffused waveguides on Y-cut …
-
Statistical Analysis of Detonation Stability
… of high-speed schlieren imaging and a pressure transducer array. This data is then processed to provide quantified statistics for the detonation cell size, Chapman-Jouguet velocity and pressure, and the Von-Neumann pressure spike helping to further the understanding of detonations.
-
Optical and acoustic beam shaping for imaging and manipulation
… were generated with a 1000-element phase-control transducer array to levitate and rotate a macro acoustic absorber by transferring linear and angular momentum from the acoustic beam to the absorber. The ratio between linear and angular momentum in the beam was measured simultaneously. With the …
-
Integrated electronics design for high-frequency intravascular ultrasound imaging
… integration of front-end electronics and the transducer array within the catheter is critical for successful implementation of CMUT-based intravascular ultrasound (IVUS) imaging catheters to enable next generation imaging tools. Therefore, this research developed and implemented …
Page 1 of 4