Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 14 of 14 for “"transfer inefficiency"”

  1. Charge transfer inefficiency of buried-channel charged coupled device registers for low temperature operation of PtSi infrared image sensors

    … to characterize factors that influence charge transfer efficiency at low temperatures ranging from 38 to 80K. These factors included frequency of operation, background signal, gate voltage, signal level, gate length, and temperature. It was found that increased gate voltage and decreased gate …

    njit Repository record for Charge transfer inefficiency of buried-channel charged coupled device registers for low temperature operation of PtSi infrared image sensors (opens in a new tab)

  2. Calibration and Correction of Detector Damage Using a Universal Detector Simulation Framework for Space Applications

    … CCD detectors in space, leading to Charge Transfer Inefficiency (CTI). CTI appears as spurious trailing events in images, affecting crucial photometric, astrometric, and morphological measurements, such as galaxy elliptical shear measurements from the Euclid space telescope. This thesis …

    the-open-u Repository record for Calibration and Correction of Detector Damage Using a Universal Detector Simulation Framework for Space Applications (opens in a new tab)

  3. Fusion neutron damage to a charge coupled device camera

    … explores changes in Dark Current (J), Charge Transfer Inefficiency (CTI), and Contrast Transfer Function (CTF) as measures of neutron damage. The camera was irradiated to a fluence, Phi, of 6.60 x 10 (exp 12) n/ cm2. The camera temperature was lowered from room temperature to 267 K at a …

    nps Repository record for Fusion neutron damage to a charge coupled device camera (opens in a new tab)

  4. Fusion neutron transient effects to charge coupled device camera images

    … the Rotating Target Neutron Source. The Contrast Transfer Function (CTF), autocorrelation function and visual comparisons were used as measures of the transient effects of the neutron irradiation on the simulated images. The CTF and visual image quality started to degrade significantly at neutron …

    nps Repository record for Fusion neutron transient effects to charge coupled device camera images (opens in a new tab)

  5. Novel Developments in Scientific EMCCDs

    … of interest are studied here including, charge transfer efficiency, gain ageing and radiation effects from protons. Many light-starved and high-speed image applications (e.g. observation from space and automated visual inspection) can benefit from Time Delay Integration (\acrshort{tdi}) as it …

    the-open-u Repository record for Novel Developments in Scientific EMCCDs (opens in a new tab)

  6. An investigation of the radiation damage experienced by the CCDs on the Gaia focal plane

    … from radiation damage, measured as the charge-transfer inefficiency (CTI), was found to be significantly less than what was predicted from the pre-flight on-ground tests. This thesis further investigates the radiation damage of the Gaia CCDs to more precisely understand the CTI behaviour; this …

    the-open-u Repository record for An investigation of the radiation damage experienced by the CCDs on the Gaia focal plane (opens in a new tab)

  7. Alternative approaches to combinational and sequential logic design.

    … tolerancing problems that result from the charge transfer inefficiency and voltage fluctuations are considered as limiting factors on the logical complexity of the gate. Chapter 4 is concerned with the subject of serial input logic. Initially it sets out to define serial input logic in terms of a …

    bath Repository record for Alternative approaches to combinational and sequential logic design. (opens in a new tab)

  8. The Impact of Radiation Damage on Electron Multiplying CCD Technology for the WFIRST Coronagraph

    … including measurements of low-signal Charge Transfer Inefficiency (CTI), dark current and Clock Induced Charge (CIC). Significant performance differences were noted between the room temperature and cryogenic irradiation case, indicating that cryogenic irradiations are instrumental to accurate …

    the-open-u Repository record for The Impact of Radiation Damage on Electron Multiplying CCD Technology for the WFIRST Coronagraph (opens in a new tab)

  9. Nmos Process Compatible Ccd And Cid Optical Imaging Arrays

    … gate structure was employed which reduced charge transfer losses to a negligible level and freed the devices of non-linear signal distortion. The large gate oxide capacitances {dollar}(3.5 times 10sp{lcub}-4{rcub}{dollar} Fm{dollar}sp{lcub}-2{rcub}){dollar} provided by the nMOS process allowed …

    uwo Repository record for Nmos Process Compatible Ccd And Cid Optical Imaging Arrays (opens in a new tab)

  10. The intra-pixel sensitivity variation of a CCD

    … images that are most likely due to the charge transfer inefficiency (CTI) of the CCD. A correction procedure for the CTI effect is presented. Using the pixel response function (PRF) which was derived from the CCD scans, instrumental point spread functions (iPSFs) were calculated from dithered …

    unsw Repository record for The intra-pixel sensitivity variation of a CCD (opens in a new tab)

  11. Genetic variation of susceptibility to fescue toxicosis in cattle

    … minus morning surface temperature), and heat-transfer inefficiency (afternoon rectal minus afternoon surface temperatures). Appetite was decreased by the E + fescue seed, but the sire groups did not differ in their response to or recovery from E + fescue seed. The E + fescue seed caused …

    vt Repository record for Genetic variation of susceptibility to fescue toxicosis in cattle (opens in a new tab)

  12. The development of CCD parallel transfer structures for analogue signal processing

    … build-up of residual signals caused by charge, transfer inefficiency: A new CCD architecture is described that substantially overcomes this limitation since signal charge transfers, and consequently residuals, are kept to a minimum. In this novel structure, a floating-gate tapped CCD operating …

    soton Repository record for The development of CCD parallel transfer structures for analogue signal processing (opens in a new tab)

  13. Characterization and mitigation of radiation damage on the Gaia Astrometric Field

    … can be disrupted by radiation-induced Charge Transfer Inefficiency (CTI). Gaia will suffer radiation damage, impacting on the science performance, which has led to a series of Radiation Campaigns (RCs) being carried out by industry to investigate these issues. The goal of this thesis is to …

    cambridge Repository record for Characterization and mitigation of radiation damage on the Gaia Astrometric Field (opens in a new tab)