Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 17 of 17 for “"transhumeral"”
-
Biomechanical Model of Transhumeral Prostheses
… clinically. A licensed prosthesis fabricated a transhumeral residual limb model to fit within a typical, harness suspended transhumeral prosthesis. A custom testing apparatus was built to hold the residual limb model and prosthesis for testing. Eight infrared markers were placed on the …
-
A modular prosthetic arm with haptic interfacing for transradial/transhumeral amputees.
… that will be suitable for both transradial and transhumeral amputees. A novel method of myoelectric control is investigated with the introduction of a haptic user interface which will enhance the functionality of the prosthesis. This approach uses haptic feedback to display information (through …
-
Diseño y desarrollo de una prótesis transhumeral adaptable y su adaptación al ciclismo
… realizado el diseño y desarrollo de una prótesis transhumeral para personas que presentan este tipo de minusvalía y su posterior adaptación al ciclismo, en este caso de competición, y está orientado en el campo tecnológico y social. Previamente se ha realizado el análisis de otras prótesis …
-
Diseño de una prótesis mecánica transhumeral de miembro superior funcional y adaptable al crecimiento del niño
… de este trabajo es diseñar una prótesis mecánica transhumeral de miembro superior que sea funcional y adaptable al crecimiento del niño. Destacamos que es una prótesis mecánica, es decir, el accionamiento de ésta debe realizarse con el otro brazo; además de ser funcional debido a que tiene …
-
Quantification of Transhumeral Prosthetic Socket Residual Limb Interface Movement Using Motion Capture and a Slip Detection Sensor
… to measure motion at the socket interface of transhumeral amputees during activities of daily living. Data were collected on six transhumeral amputees in the University of South Florida's (USF) motion analysis laboratory. One of the participants completed the collection procedures twice using …
-
Characterization of 3D Printed Lattice Structures Used in the Design of Modified Compression Release Stabilized Transhumeral Prosthetic Sockets
… both compression and release areas of a modified transhumeral CRS style socket when its density is altered? RQ2: Is it possible to create a lattice model that linearly increases the compressibility magnitudes of a single lattice structure from the compression area requirements to release area …
-
Diseño de un sistema de control de una prótesis transhumeral con actuación híbrida activada por medio de señales fisiológicas
… de un sistema de control para una prótesis transhumeral con actuación híbrida (actuación mecánica de codo y mioeléctrica de mano). Este sistema será activado mediante el reconocimiento de la intención de movimiento del usuario, que se activa mediante la lectura de señales EMG del bíceps, y …
-
The Creation of a Robotics Based Human Upper Body Model for Predictive Simulation of Prostheses Performance
… functional limitations such as a transradial or transhumeral amputation. Motion data were collected from 14 subjects: 10 non-amputees control subjects, 1 person with a transradial amputation, and 3 persons with a transhumeral amputation, in the University of South Florida's (USF) motion analysis …
-
Engineering Kinesthetic Perceptions: The Restoration of Movement Sense in Upper Limb Prosthetic Use
… In a group of participants who have undergone transhumeral amputation and TR surgery, we demonstrated that we could purposefully elicit sensations of missing hand movement and link these sensations to the movement of commercially available prosthetic components. Integrating these techniques …
-
Aplicabilitat de les corbes cusum en el control de qualitat i en l’avaluació d’efectes d’aprenentatge en cirurgia endovascular
… i terapèutics realitzats a través d’un abordatge transhumeral. MATERIAL I MÈTODES: En primer lloc, pacients consecutius afectes d’arteriopatia obliterant aorto-ilíaca, fémoro-poplítia o renal amb indicació terapèutica endovascular, tractats per cirurgians vasculars a l’Hospital del Mar de …
-
Promoting Enactment of Upper Limb Prostheses Through Novel Non-invasive Feedback Stimulation Strategies
… wrist and thumb, and further into the Hannes Arm transhumeral configuration with a novel active elbow, both equipped with embedded tactile sensing. A non-invasive, bio-inspired feedback module was integrated to close the sensorimotor loop. Additionally, a vision-aided control paradigm combining …
-
Design and Development of a Test System for an Artificial Limb Controller
… AB. Specifically targeting their model for transhumeral (TH) amputations (above the elbow) called ALC-TH. The ALC Test System is a combination of a Test Rig, a Test Device, and Test Software. It facilitates realistic testing of the ALC without relying on human test subjects by utilizing …
-
Characterizing the Visuomotor Behaviour of Upper Limb Body-Powered Prosthesis Users
… body-powered prosthesis users and three transhumeral body-powered prosthesis users completed two functional upper limb tasks while their eye gaze behaviour and movement patterns were tracked using motion capture and eye-tracking technologies. Combined data from these systems was analyzed …
-
Development of a VR/3D Hand Prosthesis Software Application: Avatar Customization and Hand Motion Control
… had its start there. Since then, below-elbow and transhumeral amputations have been performed using this technique. The e-OPRA system is an advanced version of a technique called the OPRA Implant System which is a technology in which it is possible to attach an artificial limb to the skeleton …
-
The Development of a Kinesthetic Feedback System for Lower-Limb Prosthetic Use
… kinesthetic sensations in individuals with transhumeral amputations that have undergone targeted reinnervation (TR); a surgical technique where the sensory and motor nerves formerly innervating amputated limbs are reinnervated to new muscle and skin sites. To date, no work has been published …
-
Investigations on upper limb prosthesis control with an active elbow
Les progrès de la mécatronique ont permis d’améliorer les prothèses du membre supérieur en augmentant le catalogue des mouvements prothétiques. Cependant, un fossé se creuse entre les capacités technologiques de la prothèse et leur méthode de contrôle. La commande myoélectrique, qui est la méthode …
-
Contrôle biomimétique de prothèse à partir de mouvements naturels : base de données et transformation de référentiel pour une situation réelle
Les contrôles myoélectriques pour les prothèses transhumérales entraînent souvent un taux élevé d’abandon en raison de leurs performances insatisfaisantes. Inspirés des progrès réalisés dans les contrôles exploitant les mouvements résiduels, nous avons affiné une approche alternative utilisant un …