Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"transient measurement"”.

  1. Heat Transfer in Beaded Thermocouples Mounted on Solid Substrates-- Application to Transient Measurement Errors

    … surface temperature are liable to introduce measurement errors as a result of heat transfer between the surface and the bead, and also because of the thermal inertia of the bead. For the prediction or correction of such errors, an accurate model of the thermocouple response is required. This …

    unm Repository record for Heat Transfer in Beaded Thermocouples Mounted on Solid Substrates-- Application to Transient Measurement Errors (opens in a new tab)

  2. Krūvininkų generacija ir ištraukimas befulereniuose organiniuose saulės elementuose /

    … in non-fullerene organic solar cells. Various transient measurement techniques and their improvements have been employed to study each step in the operation of organic solar cells over an exceptionally wide temporal range, from femto- to microseconds. In this work, the effects of spatial …

    vilnius Repository record for Krūvininkų generacija ir ištraukimas befulereniuose organiniuose saulės elementuose / (opens in a new tab)

  3. An automated probe for thermal conductivity measurements

    A transient technique was validated for making thermal conductivity measurements. The technique incorporated a small, effectively spherical, heat source and temperature sensing probe. The actual thermal conductivity measurements lasted 30 seconds. After approximately 15 minutes of data reduction, a …

    vt Repository record for An automated probe for thermal conductivity measurements (opens in a new tab)

  4. Optical spectroscopy on silicon vacancy defects in silicon carbide

    … of around 7ns confirmed the value of the transient measurement. (3) Also electrical excitation of the defects has been demonstrated in a SiC LED structure. (4) The investigations revealed for the first time that silicon vacancies can even exist SiC nanocrystals down to sizes of about 60 …

    wurz-thes Repository record for Optical spectroscopy on silicon vacancy defects in silicon carbide (opens in a new tab)

  5. Application of SOA-NOLM in all-optical processing

    … and ones has been analysed in terms of their transient measurement. Good agreement with a simple model of the shift register is obtained. The transient can be reduced but it will affect the extinction ratio of the pulses.

    aston Download PDF for Application of SOA-NOLM in all-optical processing (opens in a new tab)

  6. Enhancement of high power pulsed laser ablation and biological hard tissue applications

    … of liquid-enhanced laser osteotomy. Acoustic transient measurement with a piezoelectric microphone, Schlieren flash photography, and temperature measurement with an IR camera were employed to study ablation mechanisms and the effect of water spray during long-pulsed laser ablation of dental …

    texas Repository record for Enhancement of high power pulsed laser ablation and biological hard tissue applications (opens in a new tab)

  7. In situ measurements of building materials using a thermal probe

    This work concerns the in situ measurement of thermal conductivity and thermal diffusivity of building materials, so as to provide improved data for the estimation and prediction of energy efficiency in buildings. Thermal data sources and measurement methods currently used by industry to inform …

    plymouth Repository record for In situ measurements of building materials using a thermal probe (opens in a new tab)

  8. PHYSIOLOGICAL RESPONSES OF SORGHUM TO ITS ENVIRONMENT. I. LONG TERM EFFECTS OF SUBOPTIMAL TEMPERATURES ON DEVELOPMENT. II. MEASURING CONDUCTANCE AND WATER VAPOR AND CARBON DIOXIDE EXCHANGE IN CANOPIES

    … II. A technique was developed for the transient measurement of night respiration and diurnal water vapor and CO(,2) exchange in sorghum canopies. Chamber bases were designed to avoid abnormal O(,2) depletion and CO(,2) buildup in the root zone. A Li-Cor 6000 Portable Photosynthesis …

    nebraska Repository record for PHYSIOLOGICAL RESPONSES OF SORGHUM TO ITS ENVIRONMENT. I. LONG TERM EFFECTS OF SUBOPTIMAL TEMPERATURES ON DEVELOPMENT. II. MEASURING CONDUCTANCE AND WATER VAPOR AND CARBON DIOXIDE EXCHANGE IN CANOPIES (opens in a new tab)

  9. Heat transfer during spray water cooling using steady experiments

    … sample surface by the boiling water droplets. Measurement of the RMS current flowing through the copper coil enables the model to estimate the heat extracted to the cooling spray by matching the sample thermocouple temperature measurement. Heat transfer coefficients and fluxes are quantified …

    uiuc Repository record for Heat transfer during spray water cooling using steady experiments (opens in a new tab)

  10. A three dimensional surface measurement and reconstruction system for respiratory function analysis

    … not well suited in application for spirometric measurement for ambulatory monitoring. A sensor matrix measurement technique is investigated to identify suitable sensing elements with which to base an upper body surface measurement device that monitors respiration. This thesis is divided into two …

    aston Download PDF for A three dimensional surface measurement and reconstruction system for respiratory function analysis (opens in a new tab)

  11. COMPUTER CONTROLLED TRANSIENT CAPACITANCE MEASUREMENT AND ANALYSIS OF DEEP LEVELS IN SEMICONDUCTORS

    … the original algorithm such as DLTS (Deep Level Transient Spectroscopy), attention also centered on the computerization of conventional configurations. A major advantage of such upgrading is that it permits greater flexibility in the analysis and presentation of result than is possible using …

    nus Repository record for COMPUTER CONTROLLED TRANSIENT CAPACITANCE MEASUREMENT AND ANALYSIS OF DEEP LEVELS IN SEMICONDUCTORS (opens in a new tab) Download file for COMPUTER CONTROLLED TRANSIENT CAPACITANCE MEASUREMENT AND ANALYSIS OF DEEP LEVELS IN SEMICONDUCTORS (opens in a new tab)

  12. Full-custom integrated circuit design for a pulse frequency modulator.

    … tests on prototype ICs have shown that the measurement equipment introduces significant capacitive loading. A novel approach of calculating this capacitive loading from transient measurement results is described.The designed IC was extensively tested in a practical transmission system …

    sheffield-hallam Download PDF for Full-custom integrated circuit design for a pulse frequency modulator. (opens in a new tab)

  13. Characterisation of Schottky diodes and dielectric materials for millimeter wave and THz applications

    … thermal, noise and RF properties with various measurement techniques, and an easy-to-use method is introduced for the extraction of the dielectric material properties at millimeter wave frequencies. In addition, the applications of the developed thermal characterisation method for THz Schottky …

    aalto Repository record for Characterisation of Schottky diodes and dielectric materials for millimeter wave and THz applications (opens in a new tab)

  14. EVALUATION OF SENSORS AND STRATEGIES FOR CLOSED LOOP COMBUSTION CONTROL OF A GASOLINE SPARK-IGNITION TURBOCHARGED DIRECT INJECTION ENGINE

    … dilute limit through combustion cycle stability measurement during transient operating conditions. By allowing the engine to run at more dilute conditions and locating spark advance to produce combustion durations closer to MBT, lower fuel consumption is possible. Vehicle EPA drive cycle data was …

    mtu Repository record for EVALUATION OF SENSORS AND STRATEGIES FOR CLOSED LOOP COMBUSTION CONTROL OF A GASOLINE SPARK-IGNITION TURBOCHARGED DIRECT INJECTION ENGINE (opens in a new tab)

  15. Advances in Single Entity Electrochemistry for Semiconducting Nanocrystal Studies

    … noise, frequency of collisions, and final nano transients (high-resolution experiments) to discuss signal processing effects. We used ZnO NPs as a model to understand NP mass transport and the relative contribution of migration and diffusion for metal oxides. We modeled this process with the …

    unr Repository record for Advances in Single Entity Electrochemistry for Semiconducting Nanocrystal Studies (opens in a new tab)

  16. Deciphering the impact of fructose metabolism on liver mitochondrial bioenergetics

    … differences between treatment groups was a transient measurement, in which there was only a difference 15-minutes post gavage, and by 60-minutes, there was no impact on mitochondrial function. Additionally, when treated over a 14-day period, there were no changes in mitochondrial function. …

    ecu Repository record for Deciphering the impact of fructose metabolism on liver mitochondrial bioenergetics (opens in a new tab)

  17. Studium vlastností tranzistorů na bázi iontových kapalin

    Disertační práce je zaměřena na iontové kapaliny, elektrochemické tranzistory a studium jejich elektrických a dielektrických vlastností. Ke studiu elektrických vlastností iontových kapalin byla použita metoda volt-ampérové charakteristiky, ke studiu dielektrických vlastností iontových kapalin byla …

    brno-tech Repository record for Studium vlastností tranzistorů na bázi iontových kapalin (opens in a new tab)

  18. Měření tepelné vodivosti

    Bakalářská práce popisuje měřením tepelné vodivosti izolačních materiálů nestacionární metodou využívající bodový zdroj tepla a šířením tepla materiály. Je popsán použitý měřící přípravek, postup měření a přístroje použité při měření. Práce se zabývá ověřením teoretických vztahů a působením vlivů, …

    brno-tech Repository record for Měření tepelné vodivosti (opens in a new tab)