Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 40 for “"transient method"”.
-
A Transient Method of Measuring Thermal Contact Conductance Between Metal-Plastic Surfaces
The thesis describes a method developed to measure thermal contact conductance between metal-plastics surfaces by transient experiments. Published literature contains no comparable transient experimental technique and no conductance values for metal-plastics surfaces. Thermal transients set up by a …
-
Measurement of minority carrier lifetimes in nanocrystalline silicon devices using reverse-recovery transient method
… materials. The technique is the reverse-recovery transient method. A forward current in a p-n junction is suddenly switched, and a high constant reverse current flows for a certain period of time. This time is related to the time the injected minority carriers take to recombine in the base. The …
-
Determination of Permeability from Pore Network Models by Using a Novel Transient Simulation Methodology
… steady state permeability assessment methods. Therefore, a transient simulation based methodology was developed and implemented on a pore network extracted from a carbonate micro-CT scan image to compute permeability and additional transport properties. This methodology was validated …
-
Desenvolvimento de metodologias para medição de vazão em dutos de petróleo e derivados usando o radiotraçador 123I
… fluid movement in pipelines. The use of the Time Transient Method with radiotracers can add logistical and financial advantages to the flow measurement as a function of the properties of the interaction of radiation with matter. Traditionally, as proposed by the ISO 2975-7: 1977 standard for tests …
-
Experimental evaluation of several high performance surfaces for compact heat exchangers
… is made. All matrices are investigated by the transient method of testing utilizing the maximum slope analysis of Locke and include the effects of longitudinal thermal conduction as reported by Howard.
-
Measurement of the thermochemical energy discharge process in reactive packed beds of magnesium-manganese oxide
… first half of this work develops a calorimetric method for determining the energy storage densities of magnesium-manganese oxides of five Mn/Mg compositional variants between 1000-1500 ℗ʻC. Drop calorimetry measures the total enthalpy of the phases that exist at the drop temperature, from which …
-
A transient methodology for evaluating risk reduction associated with ground water remediation at leaking underground storage tank sites
A methodology to determine risk as a function of time varying concentration was developed and applied to three leaking underground storage tank sites for five remediation scenarios, to demonstrate the risk reduction associated with corrective actions and the transient nature of risk. The …
-
Gas Condensate Well Test Analysis
… gas condensate well applying the pseudo-pressure transient method. Single- or multi-phase analysis based on pseudo-pressure function has been used to analyze well test data. Both methods rely on the availability of producing gas-oil ratio data. Compositional simulation can be used in conjunction …
-
Measurement of Thermal Conductivity by the Heat Pulse Method
The purpose of this thesis is to develop a method which can be used to measure the thermal conductivity of oxide materials in the temperature range of 70 to 3000°F. Some of the many methods of measuring thermal conductivity, both transient and steady state, are reviewed. The heat pulse method which …
-
A transient numerical method for computing the flow about ducted bodies in supersonic freestreams
A transient finite-difference method was developed to compute the transonic flow about blunt lipped ducted bodies in supersonic free streams. Moretti's second order accurate and explicit method was adapted for the computation of the interior regions and a transient method, characteristics was used …
-
Skylių pernašos tyrimai organiniuose lauko tranzistoriuose /
… carrier density are reviewed. OFET fabrication methods, as well as promising and widely used methods of measuring mobility, one of the most important parameters of these devices, are distinguished in the literature. In the next part of the study, an OFET is made with a semiconductor layer of …
-
Modeling and optimization of process systems for unconventional technologies and feedstocks
… with process design, and optimization of transient process operations. The first part of the dissertation introduces a framework for modeling, simulation, and optimization of process flowsheets incorporating highly detailed physical models of important and complex process units, termed …
-
Comparação entre os regimes transiente e permanente na obtenção de curvas de permeabilidade relativa
… simulations. In this work, two different methods were used to obtain these curves: unsteady state method on the relative permeability curves. In addition, different viscosity ratios were used in order to also verify the impact of the viscosity of the fluids on sensitivity of the relative …
-
Effectiveness of energy wheels from transient measurements
… This research uses a new, low-cost, transient method to predict the effectiveness using only data obtained from transient measurements.In this thesis, an analytical model is presented for predicting the effectiveness of rotating energy wheels using only the characteristics measured on …
-
Modelagem e simulação de reatores tubulares com promotor de mistura de inertes
… of multiple gradients along with the false-transient method. The results obtained by the model were able to predict 98% of the experimental data. The higher conversions in esters were achieved for the highest temperature and lowest porosity.
-
Heat transfer and pressure drop in fixed beds of wood chips
… Dougas-fir wood chips has been studied by a transient method. Hot air at about 130°C flowed upward through 0.2 m dia x 1 m deep beds of commercially prepared wood chips which had been screened for thickness. Four different wood chip sizes were used, which varied in mean thickness from 2.44 to …
-
Investigation of Heat Transfer in Dropwise Condensation Facilitated by a Humid Airflow
… both single-phase and condensation regimes. Transient and instantaneous heat flux measurements were required to study the relationship between condensate morphology and HTC. To facilitate this, a transient inverse heat conduction method was used to characterize the time-varying surface heat …
Page 1 of 2