Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"transmission factor"”.

  1. Clarity and internal/external structure of blown polyethylene films

    <p>The direct transmission factors of linear low density and low density polyethylene blown films were measured as a function of film preparation conditions. The contribution of scattering from the film surface was investigated by separating the overall direct transmission factor into components …

    ut-knoxville Repository record for Clarity and internal/external structure of blown polyethylene films (opens in a new tab)

  2. The effect of process and polymer variables on light transmission properties of polypropylene tubular blown films

    <p>The direct light transmission factors of polypropylene (PP) tubular blown films are measured as a function of film preparation conditions such as blow-up ratio (BUR), draw down ratio (DDR), cooling rates (frost line height, FLH) and polymer variables such as molecular weight, molecular weight …

    ut-knoxville Repository record for The effect of process and polymer variables on light transmission properties of polypropylene tubular blown films (opens in a new tab)

  3. Compact Modeling of Carbon Nanotube Field-Effect Transistors for Radio-Frequency Applications

    … current components. The energy-dependent transmission probability is set to a constant factor due to the absence of an energy barrier for deriving closed-form expression for thermionic current. The thermionic current reaches the maximum value in the “flatband” case, where the conduction …

    qucosa-diss

  4. Evaluation of fast neutron shielding effectiveness in light-element compounds

    … of varying moderator/absorber ratios on the dose transmission factor. A series of experiments were carried out using a 2.5 MeV D-D neutron generator at 106 n/s intensity along with MCNPX and PHITS code simulations. The transmission factor in different experiments was found to vary from 11% up to …

    uoit Repository record for Evaluation of fast neutron shielding effectiveness in light-element compounds (opens in a new tab)

  5. Simulation studies of biopolymers under spatial and topological constraints

    … rate on r and N. Additionally, we find that the transmission factor (the ratio of the exact rate and the TST rate) has a much weaker power law dependence on r and N. Finite-size effects are observed even for chains with several hundred monomers. If metastable states are separated by high …

    texas Repository record for Simulation studies of biopolymers under spatial and topological constraints (opens in a new tab)

  6. Carbon Catabolite Regulation of Yersinia pestis Pathogenesis

    … regulation of Y. pestis biofilm formation, a key transmission factor, and 2) characterization of carbon catabolite regulation amid conditions reflective of mammalian infection. Findings demonstrate that Y. pestis biofilm formation is subject to carbon catabolite regulation in which primary carbon …

    utmb Repository record for Carbon Catabolite Regulation of Yersinia pestis Pathogenesis (opens in a new tab)

  7. Experimental Determination of Shielding Requirements for PET Medical Facilities

    … unshielded wall sums to determine the radiation transmission factor for each patient. Results: An effective linear attenuation coefficient of c = 0.226/mm was measured in this work. The results were not significantly affected by differences in patient BMI. For a particular lead shielding …

    uab Repository record for Experimental Determination of Shielding Requirements for PET Medical Facilities (opens in a new tab)

  8. The influence of collaborative fuel reduction treatments on cross-boundary wildfires east of the Cascade Range in Washington State, USA

    … (Randig and FARSITE) were used to quantify the transmission factor between landowners and the influence of fuel reduction treatments on burn probability, fire size, fire spread, flame length and fireline intensity. Collaborative treatments significantly altered predicted fire size and spread …

    washington Repository record for The influence of collaborative fuel reduction treatments on cross-boundary wildfires east of the Cascade Range in Washington State, USA (opens in a new tab)

  9. Characterization of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations

    … modeling of MLC characteristics (leaf offset and transmission factor). These same parameters, namely Eclipse’s dosimetric leaf gap and RayStation’s MLC position offset, produced clinically significant dose changes when manipulated on 5 phantom treatment plans. Finally, the dosimetric leaf gap was …

    uthsc Repository record for Characterization of Treatment Planning System Photon Beam Modeling Errors In Iroc Houston Phantom Irradiations (opens in a new tab)

  10. Analysis and Estimation of Residential Vibration Exposure from Railway Traffic in Sweden

    … Furthermore there has never been any transfer factors published for the transmission of vibrations between the ground and the foundation of buildings in Sweden. By measuring ground-borne vibrations in the ground while doing mea-surements in the foundation, data for 51 buildings have been …

    chalmers Repository record for Analysis and Estimation of Residential Vibration Exposure from Railway Traffic in Sweden (opens in a new tab)

  11. Differential analysis of student and teacher instructional expectations

    … designed to measure response to the following factors: (a) Knowledge transmission; (b) Classroom entertainment; (c) Intellectual challenge; (d) Psychological support; (e) Achievement responsibility, and (f) Formatting the class to the textbook. Eighty-six students and 85 teachers from northern …

    colostate Repository record for Differential analysis of student and teacher instructional expectations (opens in a new tab)

  12. Development of 2-3 mm proton minibeams as a new form of GRID radiotherapy

    In this study, we investigated, computationally and experimentally, the feasibility of a new form of proton GRID therapy based on an array of proton minibeams developed at the existing proton therapy clinics. The diameter of the proton minibeams is in the range of 2-3 mm. The purpose of this new …

    gatech Repository record for Development of 2-3 mm proton minibeams as a new form of GRID radiotherapy (opens in a new tab)

  13. The determinants of European office rents

    … an occupation indicator in the short term, and a transmission factor which brings user sector change to other submarkets. In this context, the four-quadrant model and relevant discussions on the interactions of submarkets justify the adoption of a multi-equation approach in the analytic …

    whiterose Download PDF for The determinants of European office rents (opens in a new tab)