Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 21 for “"transmission imaging"”

  1. Reflection and transmission imaging of thin films

    … the back end of an existing monochromatic VUV imaging beam system, which covers a wavelength range from 30-200nm. The chamber may accommodate three different expenmental configurations, allowing transmission and reflection measurements to be taken separately or at the same time. A versatile …

    dcu Repository record for Reflection and transmission imaging of thin films (opens in a new tab)

  2. Iterative transmission image reconstruction for the DPET positron emission tomograph

    <p>Positron emission tomography (PET) systems use transmission imaging to compensate for attenuation. One commercial example of this approach is the Siemens Inveon Dedicated PET (DPET), a 120mm bore system dedicated to the study of small animals. DPET transmission images are currently reconstructed …

    utk-theses Repository record for Iterative transmission image reconstruction for the DPET positron emission tomograph (opens in a new tab)

  3. The development of multiple line transmission sources for SPECT

    In this work a new kind of transmission source for SPECT imaging, based on multiple line sources, is presented. The source may be used for either simultaneous or sequential SPECT transmission imaging to measure patient specific attenuation maps. Two different, new transmission sources based on the …

    ubc Repository record for The development of multiple line transmission sources for SPECT (opens in a new tab)

  4. Point Kinetics-based Methods for Uranium Assay in Tagged Neutron Interrogation

    … external D-T neutron source allows for transmission imaging as well as fission site imaging of neutron single and double coincidences. This work develops four point kinetics-based methods of estimating enrichment from a theoretical TNI measurement. These methods expand upon traditional …

    utk-theses Repository record for Point Kinetics-based Methods for Uranium Assay in Tagged Neutron Interrogation (opens in a new tab)

  5. Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications

    … can be used for a variety of purposes, including imaging of the cargo contingent upon gamma ray energies used in interrogation. If the gamma ray energies are sufficiently well separated, as the case in $^{11}$B(d,n-$\gamma$)$^{12}$C reaction resulting in 4.4 MeV and 15.1 MeV photons, spectral …

    gatech Repository record for Cherenkov detectors for transmission studies of monoenergetic high-energy photons in active interrogation applications (opens in a new tab)

  6. Strobo-strain: Stroboscopic neutron and X-ray strain measurements in dynamically loaded engineering components

    … of stroboscopic diffraction and neutron imaging methods, taking the wind turbine gearbox bearing as an exemplar component for this study. A novel stroboscopic technique has been incorporated into a custom-built bearing rig, permitting the measurement of time-resolved subsurface strains in …

    whiterose Repository record for Strobo-strain: Stroboscopic neutron and X-ray strain measurements in dynamically loaded engineering components (opens in a new tab)

  7. Methodological aspects for improving clinical value of SPECT and MRI

    … foci. The methodology was based on SPECT transmission imaging. The accuracy of registration was about 3-5 mm. As a conclusion, improved analysis of SPECT and MR images was obtained with the carefully evaluated methodology presented in the thesis. The registration procedure for brain SPECT …

    aalto Repository record for Methodological aspects for improving clinical value of SPECT and MRI (opens in a new tab)

  8. Transillumination techniques in ophthalmic imaging

    In vivo imaging of the human cornea and retina is typically performed in a reflection geometry. Images are formed from light that has backscattered off corneal microstructures or backreflected from the retina. In this configuration, artifacts caused by superficial surface reflections are often …

    bu Repository record for Transillumination techniques in ophthalmic imaging (opens in a new tab)

  9. Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy

    … it is necessary to prioritize on innovative imaging techniques to monitor the ion-range inside the patient. Main range uncertainties result from X-ray-based calibration of the ion relative Water Equivalent Path Length (rWEPL) during the planning phase, and patient anatomical or positioning …

    lmu-germany Repository record for Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy (opens in a new tab)

  10. Scanning optical microscopy of semiconductor devices

    … technique (OBIC). This method permits the imaging of defects in semiconductor devices which may affect the electrical performance of these devices.</p><p>For the first time a theory has been developed which forms the basis of an understanding of how excess minority carriers are distributed …

    oxford Repository record for Scanning optical microscopy of semiconductor devices (opens in a new tab)

  11. “Applications of Coherent Electron Beams

    … the door to apply the concept of holographic imaging in many new areas. Off-axis holograms can now be recorded in field emission transmission electron microscopes equipped with the electron optical equivalent of a biprism. This technique allows the accurate retrieval of phase and amplitude of …

    utk-theses Repository record for “Applications of Coherent Electron Beams (opens in a new tab)

  12. Materials and Configuration from NMIS Type Neutron Imaging and Gamma Spectroscopy

    … unknown geometry and composition from neutron imaging, induced fission radiation detection, and passive and active gamma spectroscopy data. Using this procedure and simulated data from MCNP-PoliMi and MCNPX version 2.6.0, the problem was for one without knowledge of the object to determine its …

    ut-knoxville Repository record for Materials and Configuration from NMIS Type Neutron Imaging and Gamma Spectroscopy (opens in a new tab)

  13. Developing a tri-hybrid algorithm to predict patient x-ray scatter into planar imaging detectors for therapeutic photon beams

    In vivo dosimetry via transmission imaging of the therapy beam can verify the intended treatment plan was delivered to the patient. However, the EPID (electronic portal imaging device) transmission images are contaminated with patient-generated scattered photons. If this component can be accurately …

    manitoba Repository record for Developing a tri-hybrid algorithm to predict patient x-ray scatter into planar imaging detectors for therapeutic photon beams (opens in a new tab)

  14. Cosmic ray muons for spent nuclear fuel monitoring

    … with any other technique. Muon scattering and transmission are used to perform monitoring and imaging of the stored contents of dry casks loaded with spent nuclear fuel. It is shown that one missing fuel assembly can be distinguished from a fully loaded cask with a small overlapping between the …

    purdue-thes Repository record for Cosmic ray muons for spent nuclear fuel monitoring (opens in a new tab)

  15. Detection of joint inflammation in rheumatoid arthritis using multispectral diffuse optical imaging

    … need exists for novel, low-cost and noninvasive imaging tools capable of detecting inflammation in the joints for the diagnosis and monitoring of patients with rheumatoid arthritis. Diffuse optical imaging provides information about the underlying functional properties of biological tissue and …

    birmingham Repository record for Detection of joint inflammation in rheumatoid arthritis using multispectral diffuse optical imaging (opens in a new tab)

  16. High-rate Modeling and Computing for Optical Systems---Gigapixel Image Formation and X-ray Imaging Physics

    … models---gigapixel image formation, X-ray transmission and X-ray scattering---and proposes methods to formulate each task as a scalable and distributed problem which is adapted to the massively parallel architecture of Graphics Processing Units (GPUs). </p><p>For the gigapixel images, this …

    duke Repository record for High-rate Modeling and Computing for Optical Systems---Gigapixel Image Formation and X-ray Imaging Physics (opens in a new tab)

  17. Investigating Seismic Wave Scattering in Heterogeneous Environments and Implications for Seismic Imaging

    … our understanding of seismic scattering and imaging in heterogeneous media. Interest focused on probing the correlation between spatial variations in attributes that characterize the state (physical, chemical) of rocks and seismic waveform data with consideration towards potential …

    toronto-retro Repository record for Investigating Seismic Wave Scattering in Heterogeneous Environments and Implications for Seismic Imaging (opens in a new tab)

  18. Improving relative stopping power calibration in X-ray treatment planning CT using sparse proton radiographies

    … from the generic conversion curve. Ion transmission imaging, as the native imaging modality for particle therapy, can directly probe the patient-specific stopping power relative to water (RSP) distribution. While tomographic ion imaging is technically challenging, RSP information …

    lmu-germany Repository record for Improving relative stopping power calibration in X-ray treatment planning CT using sparse proton radiographies (opens in a new tab)

  19. Room Temperature Semiconductor Radiation Detectors Based on CdZnTe and CdZnTeSe

    … and nuclear waste characterization, for medical imaging devices using nuclear medicine such as positron emission tomography (PET), and for NASA space astronomy. One of the most promising semiconductors being considered for the field-deployable nuclear detector is cadmium zinc telluride (CdZnTe or …

    south-carolina Repository record for Room Temperature Semiconductor Radiation Detectors Based on CdZnTe and CdZnTeSe (opens in a new tab)

  20. Geologic heterogeneity controls on CO₂ migration and trapping

    … CO₂ and brine at reservoir conditions. Light transmission is used to visualize the flows in real time and quantify fluid saturations at the millimeter scale. Observations from these experiments help corroborate our simulation results, showing that geometry and grain size variability strongly …

    texas Repository record for Geologic heterogeneity controls on CO₂ migration and trapping (opens in a new tab)

Page 1 of 2