Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 9 of 9 for “"trigger circuit"”.

  1. A novel detection system using neutron/gamma pulse shape discrimination, for use in active interrogation environments

    … has been operated and controlled using a trigger circuit devised in this research. This circuit controlled whether the gated detector was active through the presence of light. • A radiation based detector was integrated with this trigger circuit controlling the gated detector by making the …

    lancaster Download PDF for A novel detection system using neutron/gamma pulse shape discrimination, for use in active interrogation environments (opens in a new tab)

  2. Optical detection methods for microfluidic devices

    … microfluidic devices: a glass device and printed circuit board (PCB) device. The optical hardware was accompanied by a trigger circuit that was used to process and manipulate the detected light signal. The circuit was designed with a sensitivity that would detect small changes in light from …

    colostate Repository record for Optical detection methods for microfluidic devices (opens in a new tab)

  3. Dual-beam multiple-wavelength light transmittance measurement for particle sizing in rocket motor plumes

    … testing a new analog-to-digital data converter trigger circuit, and a rotating-wheel light chopper. Optical components including beam splitters, lenses, and a fiber optic cable were installed, and existing data collection system software was modified. The new system was tested by measuring soot …

    nps Repository record for Dual-beam multiple-wavelength light transmittance measurement for particle sizing in rocket motor plumes (opens in a new tab)

  4. Magnetic Switches as Active Device Replacements for Harsh Environments

    … were based upon a parallel magnetic compression circuit, a magnetic diode circuit, a pulsed primary switch circuit, and a magnetic delay trigger circuit. Further work utilizing nonlinear magnetics in the field of electrocrushing and electrohydraulic drilling is recommended, particularly where …

    unm Repository record for Magnetic Switches as Active Device Replacements for Harsh Environments (opens in a new tab)

  5. The design and operation of a current integrator and a radiation monitor for use with U.B.C.'s 4 M.E.V. Van de Graaff generator.

    … was designed using a Miller integrating circuit consisting of a pair of condensers connected from the grid of the input tube to the plate of the output tube of an amplifier having an unfed-back gain of approximately 4000, The conditions for accurate operation of the Miller circuit have …

    ubc Repository record for The design and operation of a current integrator and a radiation monitor for use with U.B.C.'s 4 M.E.V. Van de Graaff generator. (opens in a new tab) Download PDF for The design and operation of a current integrator and a radiation monitor for use with U.B.C.'s 4 M.E.V. Van de Graaff generator. (opens in a new tab)

  6. Bistabilní systémy v elektrotechnice

    V první části práce se pojednává o bistabilitě a bifurkaci a o jejich využití. Další část se zabývá hysterezí a studiem bistabilních dynamických systémů a jejich stacionárních stavů. Poslední část je věnována klopným obvodům a simulacím v programu Pspice některých z nich.

    brno-tech Repository record for Bistabilní systémy v elektrotechnice (opens in a new tab)

  7. Active control of supersonic boundary layers using electric arc plasma actuators

    … PPJ design consists of three electrodes and two circuits. One circuit is a high-voltage, trigger circuit, which creates an arc discharge between the trigger electrode and anode, pre-ionizing the gas between the electrodes to facilitate the second arc discharge. The second circuit is a …

    uiuc Repository record for Active control of supersonic boundary layers using electric arc plasma actuators (opens in a new tab)

  8. Elektroléčba

    Cílem této práce je navrhnout jednoduchý generátor pro elektroléčbu. V úvodní části se zabývá vlastnostmi tkání a rozdělením proudů používaných v elektroléčbě. Návrhová část pak obsahuje návrh jednotlivých částí generátoru a výpočty potřebné k dosažení cíle. Výsledkem je pak schéma jednoduchého …

    brno-tech Repository record for Elektroléčba (opens in a new tab)