  1. Tropospheric Delay Modeling using GNSS Observations from Continuously Operating Reference Stations (CORS)

    … to achieve high accuracy estimation of tropospheric paraments. Either Zenith wet delay (ZWD) or Precipitable Water Vapor (PWV) can be estimated by PPP processing of GNSS data in either real time or post processing mode. PWV is further utilized as a tool from which rainfall forecasting …

    ohiolink Repository record for Tropospheric Delay Modeling using GNSS Observations from Continuously Operating Reference Stations (CORS) (opens in a new tab)

  2. New GPS Time Series Analysis and a Simplified Model to Compute an Accurate Seasonal Amplitude of Tropospheric Delay

    … estimates the seasonal amplitude of zenith tropospheric delay (ZTD) error in the GPS data on local and regional spatial scales. I process the data for the period 2008 through 2012 from eight GPS stations in eastern Ontario and western Québec using precise point positioning (PPP) online …

    uwo Repository record for New GPS Time Series Analysis and a Simplified Model to Compute an Accurate Seasonal Amplitude of Tropospheric Delay (opens in a new tab)

  3. Integration of GPS, INS and pseudolite to geo-reference surveying and mapping systems

    … analyses reveal that errors of troposphere delay modelling, differential nonlinearity and pseudolite location are sensitive to pseudolite receiver geometry. Their effect on final positioning solutions can be minimised by selecting optimal pseudolite and receiver locations, which is referred …

    unsw Repository record for Integration of GPS, INS and pseudolite to geo-reference surveying and mapping systems (opens in a new tab)

  4. Evaluation of SWEPOS second-order GNSS network stations for monitoring tropospheric water vapor

    … on the assessment of the signal propagation delay estimates from GNSS by comparison with independent data sets such as measurements from climate models and other GNSS processing. This study compares Satellite measurement with other climate models for the period of 2008 - 2011. This is the …

    chalmers Repository record for Evaluation of SWEPOS second-order GNSS network stations for monitoring tropospheric water vapor (opens in a new tab)

  5. Modeling the Neutral Atmosphere in Continuously Operating GNSS Networks using OPUS-Projects

    … Some recent studies have shown that tropospheric delay is one of the most challenging and essential error sources in space-based geodetic applications; especially, in the determination of ellipsoidal height, if it is not sufficiently accounted for.</p><p>This thesis focuses on …

    ohiolink Repository record for Modeling the Neutral Atmosphere in Continuously Operating GNSS Networks using OPUS-Projects (opens in a new tab)

  6. Quality control in monitoring precipitable water vapor with GNSS precise point positioning

    … are adopted for quality analysis for the tropospheric delay and PWV solutions within GNSS PPP positioning. Both internal reliability measure, e.g. minimum detectable size of the outlier and the external reliability measure, e.g. impact of the undetectable outliers on the estimated …

    unsw Repository record for Quality control in monitoring precipitable water vapor with GNSS precise point positioning (opens in a new tab)

  7. Detection and dynamic update of landslide deformation in plateau reservoir area using time series InSAR

    … Scatterer Polarimetric Interferometric Phase. 3)Tropospheric Delay Phase Correction for Mountainous InSAR Considering Spatial Heterogeneity. 4) Automatic Detection and Dynamic Cataloging Method for Large-Scale Active Landslides Using InSAR.

    barcelona Repository record for Detection and dynamic update of landslide deformation in plateau reservoir area using time series InSAR (opens in a new tab)

  8. Effects of atmospheric pressure loading on GPS measurements

    … during the winter and/or mismodeling of tropospheric delay during summer months [Herring, 1990]. As for the contribution due to multiple sources of loading, in most cases, by adding an expected water load (from upper 2 meters of soil) to the atmospheric pressure load, a closer agreement …

    mit Repository record for Effects of atmospheric pressure loading on GPS measurements (opens in a new tab)

  9. Detection of atmospheric water vapour using the Global Positioning System

    … become apparent from numerous studies that the delay of GPS signals in the atmosphere can also be used to study the amosphere, particularly to determine the precipitable water vapour (PWV) content of the troposphere and the total electron content (TEC) of the ionosphere. This dissertation gives …

    nwu-za Repository record for Detection of atmospheric water vapour using the Global Positioning System (opens in a new tab)

  10. Modelling and Simulation of Tropospheric Water Vapour With Gaussian Random Fields-Time dependence beyond the frozen flow hypothesis

    … Long Baseline Interferometry (VLBI) is signal delay due to tropospheric water vapour. Turbulent convection makes it inherently unpredictable and it must therefore be measured directly or modelled stochastically. In particular, realizations of delay signals are necessary to simulate the …

    chalmers Repository record for Modelling and Simulation of Tropospheric Water Vapour With Gaussian Random Fields-Time dependence beyond the frozen flow hypothesis (opens in a new tab)

  11. Analysing Locata positioning technology for slow structural displacement monitoring application

    … for a displacement monitoring system. Tropospheric delay, WiFi interference, multipath, and carrier phase cycle slips are the dominant error sources in Locata range observations. Different tropospheric models were analysed and recommendations have been made on how to effectively remove …

    unsw Repository record for Analysing Locata positioning technology for slow structural displacement monitoring application (opens in a new tab)

  12. Desenvolvimento de um programa para caracterização de eventos oceânicos/atmosféricos: aplicações usando parâmetros característicos do oceano atlântico tropical e dados da estações GNSS e meteorológica de Natal-RN, Brasil

    … Navigation Satellite System), the Zenithal Tropospheric Delay (ZTD) stands out, it is basically the sum of two components, the hydrostatic (ZHD - Zenithal Hydrostatic Delay) influenced predominantly by nitrogen and oxigen, and wet component (ZWD - Zenithal Wet Delay) influenced by the water …

    brazil-ufrn Repository record for Desenvolvimento de um programa para caracterização de eventos oceânicos/atmosféricos: aplicações usando parâmetros característicos do oceano atlântico tropical e dados da estações GNSS e meteorológica de Natal-RN, Brasil (opens in a new tab)

  13. Calibration and modelling of the main error sources in BepiColombo's radiometric data

    … the NASA/ESA/ASI Cassini mission and from ESA’s Tropospheric Delay Calibration System (TDCS), to pursue two main objectives: assess the performance of calibration techniques employed to mitigate propagation effects, and characterize and model the main error sources that limit the accuracy of the …

    bologna Embargoed

  14. Orbit determination techniques for space missions to small bodies

    … of radiometric measurements, fluctuations of the tropospheric excess path length due to atmospheric components, which represent one of the most relevant contributors to Doppler noise, should be removed through accurate calibrations. A prototype of a Tropospheric Delay Calibration System (TDCS), …

    bologna Repository record for Orbit determination techniques for space missions to small bodies (opens in a new tab)

  15. Estimativa do vapor d’água integrado utilizando dados de estações GNSS terrestres para aplicações na troposfera sobre as cidades de Natal e Mossoró, no Estado do Rio Grande do Norte, Brasil

    … surface. However, the satellite signal is delayed as it crosses the earth's atmosphere, specifically in two of its layers: (a) the ionospheric layer, where the signal is delayed by ionized atoms present in this region, and (b) the tropospheric layer, due to the presence of water vapor, and …

    brazil-ufrn Repository record for Estimativa do vapor d’água integrado utilizando dados de estações GNSS terrestres para aplicações na troposfera sobre as cidades de Natal e Mossoró, no Estado do Rio Grande do Norte, Brasil (opens in a new tab)

  16. Efeitos da refração troposférica no posicionamento por ponto preciso no Brasil

    … O atraso zenital troposférico (ZTD - Zenith Tropospheric Delay), ou refração troposférica, é a principal fonte de erro no posicionamento com GNSS devido à troposfera. Destaca-se que há poucos estudos que comparam os modelos de correção da refração troposférica associados às funções de …

    brazil-ufv Repository record for Efeitos da refração troposférica no posicionamento por ponto preciso no Brasil (opens in a new tab)

  17. Geosynchronous synthetic aperture radar: design and applications

    … function. The analysis shows that ionospheric delay is the major source of decorrelation; other effects, such as tropospheric delay and Earth tides, have to be dealt with but appear to be easier to handle. Two different options for GeoSAR interferometry have been discussed. The system is well …

    cranfield Repository record for Geosynchronous synthetic aperture radar: design and applications (opens in a new tab)

  18. Integration, characterization, and calibration of the high-frequency airborne microwave and millimeter-wave radiometer (HAMMR) instrument

    … 18-34 GHz microwave radiometers to measure wet-tropospheric path delay. Due to the large antenna footprint sizes at these frequencies, the accuracy of wet path retrievals is substantially degraded within 40 km of coastlines, and retrievals are not provided over land. A viable approach to improve …

    colostate Repository record for Integration, characterization, and calibration of the high-frequency airborne microwave and millimeter-wave radiometer (HAMMR) instrument (opens in a new tab)

Page 1 of 2