  1. AUTONOMOUS ONBOARD CORRECTION OF INFRARED PIXEL RESPONSE FOR THE TERAHERTZ IMAGING CAMERA (TIC)

    This thesis examines calibration and detector correction methods for the CRIUS 1280 infrared camera used within the Terahertz Imaging Camera (TIC), a hybrid THz-to-IR imaging system designed to detect extremely small terahertz-induced temperature variations. Because TIC must measure temperature …

    nps Repository record for AUTONOMOUS ONBOARD CORRECTION OF INFRARED PIXEL RESPONSE FOR THE TERAHERTZ IMAGING CAMERA (TIC) (opens in a new tab)

  2. High volume instrument measurement of cotton fiber elongation – history, calibration, and utility

    … practical. The recent development of elongation calibration cottons for high-speed tensile testing has renewed interest in characterizing cotton for strength and elongation. A round trial of ten Australian and US instruments was conducted on six cotton samples representing a range of 4.9% to 8.1% …

    ttu Repository record for High volume instrument measurement of cotton fiber elongation – history, calibration, and utility (opens in a new tab)

  3. A compact borehole, thermal-infrared radiometer and infrared reflectometer for the characterization of subsurface habitability and presence of water ice on Mars

    … channels included a variety of minerals and a two point calibration method. The results were compared to the predicted reflectance values for the samples. The results of the reflectance channel testing demonstrated that the measured values matched the predicted values with a 2.5% measured …

    oxford Repository record for A compact borehole, thermal-infrared radiometer and infrared reflectometer for the characterization of subsurface habitability and presence of water ice on Mars (opens in a new tab)

  4. Modeling Study of Proposed Field Calibration Source Using K-40 Source and High-Z Targets for Sodium Iodide Detector

    … high-Z metals between 60 and 80 keV. A gamma ray calibration source is thus proposed that uses potassium chloride salt and a high-Z metal to create a two-point calibration for a sodium iodide field gamma spectroscopy instrument. The calibration source was designed in collaboration with Sandia …

    tamu Repository record for Modeling Study of Proposed Field Calibration Source Using K-40 Source and High-Z Targets for Sodium Iodide Detector (opens in a new tab)

  5. Rozšíření modelu portálové vrtačky

    Bakalárska práca sa zaoberá rozšírením laboratórneho modelu portálovej vŕtačky o spojité meranie polohy hlavy v osi posuvu pomocou ultrazvukového snímača s prúdovým výstupom 4–20 mA. Súčasťou riešenia je návrh a výroba držiaka snímača, realizácia elektroinštalácie a pripojenie na analógové vstupy …

    brno-tech Repository record for Rozšíření modelu portálové vrtačky (opens in a new tab)

  6. Development of an Injectable Ablative Therapy for Resource-Limited Settings: Applications in Tumor Ablation

    <p>Although two-thirds of the global cancer mortality burden is predicted to occur in low- and middle-income countries (LMICs), citizens of these countries have disproportionately less access to resources and facilities to provide effective care. Surgery, radiation therapy, and chemotherapy form …

    duke Repository record for Development of an Injectable Ablative Therapy for Resource-Limited Settings: Applications in Tumor Ablation (opens in a new tab)