Showing 1 to 20 of 427 for “"ultimate limit state"”.
-
Ultimate limit state analysis of externally post-tensioned structures.
… the concrete and the external tendons, the ultimate strength of these structures cannot be determined by just performing a sectional analysis at the section of maximum moment. Although several recommendations have been made for the ultimate analysis of these structures, none were considered …
-
3D ultimate limit state analysis using discontinuity layout optimization
… layout optimization (DLO) procedure uses limit analysis theory to directly obtain upper bounds on plane strain collapse loads of bodies and has successfully been applied to geotechnical problems. In this thesis, a new three-dimensional formulation of DLO is described. The new formulation …
-
Ultimate limit state of corroded double bottom tanker after grounding events
… the event of a ship grounding. Furthermore, the ultimate hull girder strength and residual strength of the hull after various grounding scenarios is investigated. Nonlinear finite element analysis simulations are conducted in Abaqus/Explicit (Dassault Systèmes, 2020). Displacement controlled …
-
Ultimate Limit State Response of Reinforced Concrete Columns for Use in Performance-Based Analysis and Design
… events requires accurate predictions of the ultimate rotational capacity of critical sections, which is dictated by the failure mechanisms of shear, hoop fracture, low-cycle fatigue and longitudinal bar buckling. The purpose of this research is to develop a model for the full compressive …
-
Structural Revision of an Independent Cargo Tank: Investigation of Ultimate Limit State and Fatigue Limit State
This thesis is dealing with Ultimate Limit State and Fatigue Limit State of an independent cargo tank for bitumen carriers. The cargo tank has been investigated with main focus on the upper and lower edge of the longitudinal watertight tank bulkhead. The main question is how can the stress …
-
Seismic safety evaluation of industrial piping systems and components under serviceability and ultimate limit state conditions.
… seismic capacities and demands under different limit states, could be utilized for the amendment of relevant design Codes and Standards. This thesis undertook a numerical and experimental investigation on a typical industrial piping system and some of its components in order to assess their …
-
An investigation into the behaviour of hollow ribbed (waffle) rectangular reinforced concrete slabs at ultimate limit state
The elastic to ultimate load behaviour of reinforced concrete waffle slabs subjected to uniformly distributed load and 4-point loads are reported in this thesis. A total of twenty 1/4- and one 1/2-scale reinforced concrete waffle model slabs, with different area of steel and rib depth to slab …
-
Service and Ultimate Limit State Flexural Behavior of One-Way Concrete Slabs Reinforced with Corrosion-Resistant Reinforcing Bars
… influences flexural performance at service and ultimate limit states. Moment-curvature predictions from the computer-based sectional analysis program Response 2000 were consistent with the tested results, demonstrating its viability for use with high strength and non-metallic bar without a …
-
Random fields and Bayesian methods for the uncertainty quantification of hull girder ultimate strength and their impact on the reliability of ship structures in ultimate limit state
… is governed by their performance in extreme or ultimate limit state. The rational treatment and quantification of the uncertainties associated with the load and resistance models is meaningful for a proper reliability analysis. In this thesis, the focus is placed on developing new methods for …
-
Full scale testing of corrugated metal culvert pipe rehabilitated with shotcrete liner
… test culvert pipe was loaded to its ultimate limit state until the failure of compacted granular fill surface at the top. Results showed that, the ultimate limit state was achieved at a load approximately eight times the service load. The conduit walls of shotcrete lined test culvert …
-
Limit States Testing of a Buried Deep-Corrugated Large-Span Box Culvert
… larger than the design values to identify the ultimate limit state(s) of the structure. An ultimate limit state was encountered at approximately 800 kN where the geotechnical resistance beneath the loading pads was exceeded. A subsequent test with the loading pad force spread over larger areas …
-
A mechanics simulation of the influence of reinforcement corrosion on RC beam behaviour
Corrosion influences both of the serviceability limit state and the ultimate limit state of the reinforced concrete structures. The mass loss of reinforcement caused by corrosion not only reduces cross sectional area of the reinforcement but also the bond between the steel reinforcement and …
-
A study of secondary moments and moment redistribution in continuous prestressed concrete beams
… a stiffness analysis. Beyond the Serviceability Limit State, the beam will begin to crack, altering the flexural stiffness as well as causing local increases in the tendon force, in turn altering the Secondary Moment. Therefore if the designer wishes to incorporate Moment Redistribution at the …
-
Limit state design for biodeterioration - a new paradigm for management of fungal risks in biobased building materials
… to consider how these failures manifest. The limit state design framework is an approach used by engineers to describe the risks of failure. It defines the probabilistic failure envelope of an inherent resistance being exceeded by a given load. The competing loads and resistances, in this …
-
The Development and Use of a Test Facility for Large Diameter Pipes
… steel pipe, were tested to study their strength limit states while evaluating the facility. The 3.05 m diameter composite pipe supported a maximum overburden pressure of 224 kPa and reached its ultimate limit state at a total overburden pressure of 258 kPa. The pipe failed as a result of local …
-
Finite Element Analysis of Profiled High Density Polyethylene Stormwater Arches Under Live Loading
… of the arch structure up to and past its ultimate limit state. The explicit three-dimensional geometry of the tested arch specimen was measured in detail using a laser scanner, and tensile index tests were carried out to calibrate a viscoplastic constitutive model. The analysis was capable …
-
Ultimate strength study of composite plates
… estimates need to be reviewed in order to limit the costs. The purpose of this thesis is to contribute to the development of methods for calculating the ultimate limit state (ULS) of fibre- reinforced plastic panels with less conservative estimates compared to traditional methods used in …
-
Performance and Assessment of Rehabilitated Steel Culverts
… the rehabilitated culverts were loaded to their ultimate limit states. Results showed that the low and high strength grouted slip-liners provided strength well beyond requirements, with the low strength specimen failing at a load 2.4 times the fully factored service load, while the high strength …
-
Physical Testing and Finite Element Analysis of a Corrugated High-Density Polyethylene Stormwater Arch Under Deep Burial
… investigation of the failure mechanism and the ultimate limit state under deep burial conditions. This thesis first presents results from a full-scale experiment of two buried, corrugated, high-density polyethylene arches with a 350 mm rise, 690 mm span, and 150 mm spacing surrounded by …