Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"ultra low dose"”.

  1. Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging

    … imaging bias, but leads to the higher radiation dose to the patient. Lowering the CT source flux level to reduce dose, however, leads to increased noise and bias. Here we test the possibility of using model based iterative reconstruction algorithms (MBIRs) for generating the sparse-view, …

    washington Repository record for Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging (opens in a new tab)

  2. Ultra-Low Dose Antagonist Effects on Cannabinoids and Opioids in Models of Pain: Is Less More?

    An ultra-low dose of a drug is approximately 1000-fold lower than the dose range traditionally used to induce a therapeutic effect. The purpose of the present thesis was to broaden the knowledge of the ultra-low dose effect, that was previously identified in the opioid receptor system, by looking …

    queens Repository record for Ultra-Low Dose Antagonist Effects on Cannabinoids and Opioids in Models of Pain: Is Less More? (opens in a new tab)

  3. Attenuation of morphine tolerance, reward, and spinal gliosis in neuropathic pain by ultra-low dose alpha2-adrenergic antagonists

    … alleviates the mechanical hypersensitivity following nerve injury, inhibits chronic morphine and nerve injury-induced glial and neuronal activation in the spinal dorsal horn, and disrupts opioid reward in chronic pain states.

    queens Repository record for Attenuation of morphine tolerance, reward, and spinal gliosis in neuropathic pain by ultra-low dose alpha2-adrenergic antagonists (opens in a new tab)

  4. Opioids and Glia: Investigating the Mechanisms Through Which Ultra-Low Dose Opioid Antagonists Modulate Opioid Tolerance and Hyperalgesia

    Ultra-low doses (ULD) of the opioid receptor antagonists, naloxone and naltrexone, augment the analgesic actions of morphine, block the induction of tolerance, and reverse established tolerance by an unknown mechanism. Preclinical studies demonstrate that chronic morphine administration induces …

    queens Repository record for Opioids and Glia: Investigating the Mechanisms Through Which Ultra-Low Dose Opioid Antagonists Modulate Opioid Tolerance and Hyperalgesia (opens in a new tab)

  5. Vergleich von Ultra-Low-Dose-Computertomographie und digitaler Radiographie mit gleicher effektiver Dosis in der Diagnostik kindlicher Frakturen anhand eines Ferkelmodells

    … wurden die ULD-CTs ausgewählt, deren effektiven Dosen den der Röntgendosen entsprachen. Die Befundung erfolgte durch zwei Kinderradiologen. Insgesamt war die ULD-CTs trotz reduzierter Bildqualität den Röntgenbildern mit gleicher effektiver Dosis in der Diagnostik kindlicher Frakturen überlegen. …

    cau-kiel Repository record for Vergleich von Ultra-Low-Dose-Computertomographie und digitaler Radiographie mit gleicher effektiver Dosis in der Diagnostik kindlicher Frakturen anhand eines Ferkelmodells (opens in a new tab)

  6. Einfluss eines Schilddrüsenschutzes auf die effektive Dosis von „Ultra-Low-Dose“ DVT-Protokollen in Verbindung mit kleinen und mittleren Fields of View

    Zielsetzung: Die digitale Volumentomographie (DVT) ist aufgrund ihrer hochauflösenden, dreidimensionalen Darstellungsmöglichkeiten ein etabliertes Verfahren in der zahnärztlichen Radiologie. Mit zunehmender Anwendung bestehen Bedenken hinsichtlich der damit verbundenen Strahlenbelastung für die …

    fu-berlin Repository record for Einfluss eines Schilddrüsenschutzes auf die effektive Dosis von „Ultra-Low-Dose“ DVT-Protokollen in Verbindung mit kleinen und mittleren Fields of View (opens in a new tab)

  7. Image quality and radiation optimization in children‘s nonsyndromic craniosynostosis computer tomography /

    … purpose of the dissertation is to develop a CT dose optimization algorithm based on the generation of ultra-low dose CT images from retrospective images using modification with simulated noises corresponding to the reduced X-ray tube current and time product (mAs) values. Tasks: 1) to analyze …

    vilnius Repository record for Image quality and radiation optimization in children‘s nonsyndromic craniosynostosis computer tomography / (opens in a new tab)

  8. Reduction of CT dose for CT-based PET attenuation correction

    … However, for both methods, the radiation dose from the CT scan is unacceptably high with the current CT techniques. This directly limits the clinical application of the quantitative PET imaging. Ultra-low dose CT for PET attenuation correction is studied for lung cancer imaging. Selected …

    washington Repository record for Reduction of CT dose for CT-based PET attenuation correction (opens in a new tab)

  9. Advanced imaging and data mining technologies for medical and food safety applications

    … which include 1) noise reduction of ultra-low-dose multi-slice helical CT imaging for early lung cancer screening, and 2) automated discrimination between walnut shell and meat under hyperspectral florescence imaging. In the medical imaging and diagnosis area, because X-ray computed …

    maryland Repository record for Advanced imaging and data mining technologies for medical and food safety applications (opens in a new tab)

  10. Gene by Environment Interaction Leads to Sensitivity to the Anti-Aggressive Effect of Δ9-Tetrahydrocannabinol

    … by environment (GxE) interaction between the low transcriptional activity polymorphisms of MAOA (MAOA-uVNTR) and early life stress such as childhood neglect or abuse. Given that reactive aggressive individuals tend to consume cannabis, it was hypothesized that this GxE interaction leads to …

    ku Repository record for Gene by Environment Interaction Leads to Sensitivity to the Anti-Aggressive Effect of Δ9-Tetrahydrocannabinol (opens in a new tab)

  11. NEUROKININ 1 RECEPTORS AND THEIR ROLE IN OPIOID-INDUCED HYPERALGESIA, ANTINOCICEPTIVE TOLERANCE AND REWARD

    … patients to achieve appropriate pain relief at doses which are tolerable over long periods of time.Opiates (natural products), or opioids (synthetic derivatives), are considered the gold standard of analgesic care, though with little efficacy for neuropathic pain. Opioids are associated with …

    arizona-thes Repository record for NEUROKININ 1 RECEPTORS AND THEIR ROLE IN OPIOID-INDUCED HYPERALGESIA, ANTINOCICEPTIVE TOLERANCE AND REWARD (opens in a new tab)

  12. High-Speed Reconstruction of Low-Dose CT Using Iterative Techniques for Image-Guided Interventions

    … limits its current and future use. We perform ultra low-dose scanning to overcome this limitation. To address the image quality problem at low doses, we reconstruct images using the iterative Paraboloidal Surrogate(PS) algorithm. Using actual scanner data, we demonstrate improvement in the …

    maryland Repository record for High-Speed Reconstruction of Low-Dose CT Using Iterative Techniques for Image-Guided Interventions (opens in a new tab)

  13. Επιδράσεις των αντισυλληπτικών από του στόματος στην οστική πυκνότητα

    … εφήβων. Ωστόσο, τα χαμηλής δόσης συνδυασμένα (low-dose COCs) φαίνεται να είναι πιο προστατευτικά για την οστική πυκνότητα από τα πολύ χαμηλής δόσης (ultra-low dose COCs). Στις προεμμηνοπαυσιακές γυναίκες, οι οποίες διατηρούν καλή ωοθηκική λειτουργία και δεν έχουν ανεπάρκεια οιστρογόνων, τα …

    athens Repository record for Επιδράσεις των αντισυλληπτικών από του στόματος στην οστική πυκνότητα (opens in a new tab)

  14. Applications of Statistical Modeling in Iterative CT Image Reconstruction

    … especially so if the scans are performed at low x-ray dose, and advanced statistical estimation techniques have been shown to produce higher quality images than FBP. This work presents two applications of statistical modeling in CT image reconstruction. The first application discusses the …

    washington Repository record for Applications of Statistical Modeling in Iterative CT Image Reconstruction (opens in a new tab)

  15. Effects of low dose ionizing radiation on transcriptional expression of DNA repair and reactive oxygen species scavenging genes: Studies at Chornobyl

    … IR studies have assessed the effects of high dose, acute exposures; however a recent shift in radiation biology has focused its efforts to cellular responses of low dose IR exposure. We used the radioactive environment surrounding the Chornobyl Nuclear Power Plant to assess the potential for …

    ttu Repository record for Effects of low dose ionizing radiation on transcriptional expression of DNA repair and reactive oxygen species scavenging genes: Studies at Chornobyl (opens in a new tab)

Page 1 of 2