Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 62 for “"ultra-trace"”.

  1. Graphene Sensors for Ultra-Trace Detection of Environmental Contaminants

    … to chemically diverse analytes, particularly for ultra-trace detection. This dissertation addresses these challenges through the development of graphene-based sensing platforms for ultra-trace environmental contaminant detection by systematically engineering sensing interfaces, device …

    umn Repository record for Graphene Sensors for Ultra-Trace Detection of Environmental Contaminants (opens in a new tab)

  2. Analytical strategies for ultra-trace measurement of dioxins and related compounds in biological matrices

    … of Dechloranes in food. The measurement of ultra-trace levels of compounds from this emerging class of flame-retardants was possible after optimization of the injections parameters by means of experimental design, and of fragmentation pathways. Eventually, we reported relatively low levels …

    liege Repository record for Analytical strategies for ultra-trace measurement of dioxins and related compounds in biological matrices (opens in a new tab) Restricted access

  3. The atomic absorption determination of ultra-trace tellurium in rocks utilizing high sensitivity sampling systems

    … the required sensitivity to detect tellurium at ultra-trace levels, in a variety of sample types, by atomic absorption. In the sampling boat approach, tellurium in sample solutions is chemically separated and concentrated by extraction into methyl isobutyl ketone before measurement. For samples …

    must-thes Repository record for The atomic absorption determination of ultra-trace tellurium in rocks utilizing high sensitivity sampling systems (opens in a new tab)

  4. Forensic Science Applications Utilizing Nanomanipulation-Coupled to Nanospray Ionization-Mass Spectrometry for the Analysis of Ultra-Trace Illicit Drugs

    … instrumentation for the recovery and analysis of ultra-trace illicit drug residues. The electrostatic dust lifting process is coupled with nanomanipulation-nanospray ionization to retrieve drug particles off of hard surfaces for analysis. For the second method, drug residues from fingerprint …

    unt Repository record for Forensic Science Applications Utilizing Nanomanipulation-Coupled to Nanospray Ionization-Mass Spectrometry for the Analysis of Ultra-Trace Illicit Drugs (opens in a new tab)

  5. Ferrofluid-Based Preconcentration Methods for the Ultra-Trace Determination of Analytes in Complex Matrices with Inductively Coupled Plasma Mass Spectrometry

    Ultra-trace determination of noble metals and other pathfinder elements is becoming increasingly used as an effective method for mineral exploration to locate undercover ore deposits. For ultra-trace determination of analytes in complex matrices by inductively coupled plasma mass spectrometry …

    queens Repository record for Ferrofluid-Based Preconcentration Methods for the Ultra-Trace Determination of Analytes in Complex Matrices with Inductively Coupled Plasma Mass Spectrometry (opens in a new tab)

  6. A Method for High Precision Determination of up to 57 Trace and Ultra-Trace Elements in Crude Oils Using Triple Quad-Icp-Ms with Applications in Exploration, Production Allocation, and Refining

    … were input into a program developed called “ALLO-TRACE” to calculate the contributing fractions of the end-member oils to the commingled oil using multiple analyte-based linear equations. Accuracies and uncertainties in terms of RSDs of most calculations are within 4% and 3%, respectively. The …

    houston Repository record for A Method for High Precision Determination of up to 57 Trace and Ultra-Trace Elements in Crude Oils Using Triple Quad-Icp-Ms with Applications in Exploration, Production Allocation, and Refining (opens in a new tab)

  7. Development of a laser ablation quadrupole ion trap mass spectrometer for direct spectrometry of solid samples

    … contamination and result in further dilution of trace analytes. Methods of direct solid analysis obviate this step, and can provide compositional information for solid materials. To achieve very low detection limits for analytes in solid samples requires special methodology. One way to achieve …

    ubc Repository record for Development of a laser ablation quadrupole ion trap mass spectrometer for direct spectrometry of solid samples (opens in a new tab) Download PDF for Development of a laser ablation quadrupole ion trap mass spectrometer for direct spectrometry of solid samples (opens in a new tab)

  8. Application of thermal ion-molecule reactions in tackling spectroscopic inferences in inductively coupled plasma mass spectrometry

    Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in …

    brock Repository record for Application of thermal ion-molecule reactions in tackling spectroscopic inferences in inductively coupled plasma mass spectrometry (opens in a new tab)

  9. Development of Ultrasensitive Analytical Techniques to Detect Trace Elements

    <p>In this thesis, two methods for ultra-trace analysis were investigated: the negative-ion based Accelerator Mass Spectrometry (AMS) and positive-ion based Resonant Ionization Mass Spectrometry (RIMS). The detection, monitoring and quantification of ultra-low levels of actinides is of considerable …

    utk-theses Repository record for Development of Ultrasensitive Analytical Techniques to Detect Trace Elements (opens in a new tab)

  10. Environmental Monitoring of Per-and Polyfluoroalkyl Substances Using Microextraction Methodologies

    … Their widespread use has led to the detection of trace and ultra-trace concentrations of various PFAS in environmental matrices. Even at low concentrations, exposure to PFAS has been linked to adverse health effects, including pregnancy-induced hypertension, developmental toxicity in infants due …

    buffalo Repository record for Environmental Monitoring of Per-and Polyfluoroalkyl Substances Using Microextraction Methodologies (opens in a new tab)

  11. Advancing Strategies for the Removal, Detection, and Biochemical Interaction Assessment of Per- and Polyfluoroalkyl Substances (PFAS)

    … of PFAS from water and the detection of PFAS at ultra-trace concentrations. Using UiO-67 for the removal of PFAS, 99% of a 2 parts per billion solution were removed from water. Additionally, the use of UiO-66 for the quantification of PFAS resulted in average detection limits of 144 parts per …

    unsw Repository record for Advancing Strategies for the Removal, Detection, and Biochemical Interaction Assessment of Per- and Polyfluoroalkyl Substances (PFAS) (opens in a new tab) Embargoed

Page 1 of 4