Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"ultrashort echo time"”.

  1. Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung

    In this thesis, a 3D Ultrashort echo time (3D-UTE) sequence was introduced in the Self-gated Non-Contrast-Enhanced Functional Lung Imaging (SENCEFUL) framework. The sequence was developed and implemented on a 3 Tesla MR scanner. The 3D-UTE technique consisted of a nonselective RF pulse followed by …

    wurz-thes Repository record for Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung (opens in a new tab)

  2. MRI Quantification of Cortical Bone Microstructure and Material Composition with Ultrashort Echo Time Sequences

    … in vivo in clinically practical acquisition times. Therefore, the primary objective of this dissertation was to perform the first investigation of these cortical bone parameters in patients with diagnosed bone disease, and to explore the potential clinical translatability of these techniques. …

    penn Repository record for MRI Quantification of Cortical Bone Microstructure and Material Composition with Ultrashort Echo Time Sequences (opens in a new tab) Embargoed until 2027-06-14

  3. Modelling the short-T2* signal in the liver with ultrashort echo time magnetic resonance imaging (UTE-MRI)

    … However, collagen signal is measurable with the ultrashort echo time (UTE) sequence, which can achieve an echo time of less than 1 ms. This thesis explored the modelling of the short-T<sub>2</sub><sup>*</sup> signal in the liver with UTE.</p> <p>Given the implication of collagen in liver disease, …

    oxford Repository record for Modelling the short-T2* signal in the liver with ultrashort echo time magnetic resonance imaging (UTE-MRI) (opens in a new tab)

  4. Study of UTE and ZTE Sequences at Ultra-High Magnetic Field Strengths

    UTE (Ultrashort Echo Time) and ZTE (Zero Echo Time) sequences have found to detect short T2 relaxation signals coming from regions that are not detected by conventional MRI methods. Due to the high dipole-dipole interactions in solid and semi-solid tissues, the echo time generated is simply not …

    buffalo Repository record for Study of UTE and ZTE Sequences at Ultra-High Magnetic Field Strengths (opens in a new tab)

  5. Detailed bone assessment of the sacroiliac joint in a prospective imaging study: Comparison between computed tomography, zero echo time, and black bone magnetic resonance imaging

    Objectives: To compare the value of zero echo time (ZTE) and gradient echo "black bone" (BB) MRI sequences for bone assessment of the sacroiliac joint (SI) using computed tomography (CT) as the reference standard. Materials and methods: Between May 2019 and January 2021, 79 patients prospectively …

    zurich Repository record for Detailed bone assessment of the sacroiliac joint in a prospective imaging study: Comparison between computed tomography, zero echo time, and black bone magnetic resonance imaging (opens in a new tab)

  6. Pulse sequence design for fast and flexible sodium magnetic resonance imaging

    … transverse relaxation. Three-dimensional (3D) ultrashort echo time (UTE) sequences, often used for ²³Na MRI, involve whole-volume acquisitions that require scan times of 10–34 min. Two-dimensional (2D) UTE sequences can be used to image a reduced number of slices, but scan times range 8–10 min …

    ubc Repository record for Pulse sequence design for fast and flexible sodium magnetic resonance imaging (opens in a new tab) Download PDF for Pulse sequence design for fast and flexible sodium magnetic resonance imaging (opens in a new tab)

  7. Changes in UTE-T2* Relaxation Time MRI of Cartilage with Load in Individuals with Early Knee Osteoarthritis

    … not detectable using conventional imaging (1–3). Ultrashort echo time (UTE) imaging enables evaluation of short T2 tissues such as the deep layer of articular cartilage (4). In addition, imaging the knee under loading conditions may enhance the detection of early osteoarthritis (OA)-related …

    sask Repository record for Changes in UTE-T2* Relaxation Time MRI of Cartilage with Load in Individuals with Early Knee Osteoarthritis (opens in a new tab)

  8. Robust Magnetic Resonance Imaging of Short T2 Tissues

    Tissues with short transverse relaxation times are defined as ‘short T2 tissues’, and short T2 tissues often appear dark on images generated by conventional magnetic resonance imaging techniques. Common short T2 tissues include tendons, meniscus, and cortical bone. Ultrashort Echo Time (UTE) pulse …

    sask Repository record for Robust Magnetic Resonance Imaging of Short T2 Tissues (opens in a new tab)

  9. MRI Characterization of Peripheral Arterial Disease for Planning Percutaneous Vascular Interventions

    … We have developed an MRI method using ultrashort echo time and steady state free precession flow-independent imaging that characterizes hard versus soft peripheral arterial lesion components and related those characteristics to ease of crossing during PVI. We performed ex-vivo studies …

    toronto-retro Repository record for MRI Characterization of Peripheral Arterial Disease for Planning Percutaneous Vascular Interventions (opens in a new tab)

  10. DEVELOPMENT AND CLINICAL TRANSLATION OF MRI METHODS FOR QUANTITATIVE ASSESSMENT OF ORGAN PHYSIOLOGY AND TISSUE STRUCTURE

    … the DURANDE sequence (dual-radiofrequency, dual-echo ultrashort echo time) was quantitatively compared to other craniofacial-imaging techniques. Furthermore, DURANDE’s clinical feasibility was investigated in pediatric patients with craniofacial abnormalities. The bone-selective images were …

    penn Repository record for DEVELOPMENT AND CLINICAL TRANSLATION OF MRI METHODS FOR QUANTITATIVE ASSESSMENT OF ORGAN PHYSIOLOGY AND TISSUE STRUCTURE (opens in a new tab)

  11. Advances in magnetic resonance imaging reconstruction methods incorporating prior knowledge

    … undersampling in an effort to reduce scan times. This can lead to artefacts in the reconstructed images.<br/>In this thesis two emerging clinical applications of MRI are considered: hybrid<br/>PET-MR imaging and coronary MR angiography (CMRA). Factors giving rise to<br/>substantial …

    kings Repository record for Advances in magnetic resonance imaging reconstruction methods incorporating prior knowledge (opens in a new tab) Download PDF for Advances in magnetic resonance imaging reconstruction methods incorporating prior knowledge (opens in a new tab)

  12. Magnetic Resonance Imaging Techniques For Contrast - Enhanced Cellular And Molecular Imaging

    … detection sensitivity offered by a Multiple-Echo Ultrashort Echo Time (MUTE) MRI technique was demonstrated. In addition, I proposed a novel method that provides robust positive contrast with high temporal efficiency to advance cellular tracking technology. The physical principles of positive …

    nus Repository record for Magnetic Resonance Imaging Techniques For Contrast - Enhanced Cellular And Molecular Imaging (opens in a new tab) Download file for Magnetic Resonance Imaging Techniques For Contrast - Enhanced Cellular And Molecular Imaging (opens in a new tab)

  13. Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties

    … tendon cross-sectional area, thickness, echogenicity, stiffness, and T2*) responses to loading forces are variable and measurable in vivo. These responses impact the physiologic function of the tendon. Aims: 1) To evaluate baseline Achilles tendon biomechanical characteristics associated …

    byu Repository record for Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties (opens in a new tab) Download PDF for Loading Force in Recreational Runners and its Effect on Achilles Tendon Biomechanical Properties (opens in a new tab)

  14. MRI-based radiomics: Quantifying the stability and reproducibility of tumour heterogeneity in vivo and in a 3D printed phantom

    … segmentation however was only visible with an ultrashort echo time sequence, not commonly used in SOC imaging. Chapter 5 investigates a high temperature resin (‘white resin’) where a texture object was developed for analysis. The ‘white resin’ was visible using SOC sequences. The interscanner …

    unsw Repository record for MRI-based radiomics: Quantifying the stability and reproducibility of tumour heterogeneity in vivo and in a 3D printed phantom (opens in a new tab)

  15. Advanced acquisition and reconstruction methods for MRI of tissues with short T2 or T2*

    … to detect the fast decaying signal. Ultra-short Echo Time (UTE) and Zero Echo Time (ZTE) sequences are the imaging methods that can achieve a TE < T2*, by employing pure frequency encoding in a 3D radial center-out acquisition. These methods have many potential clinical applications, including …

    freiburg-diss Repository record for Advanced acquisition and reconstruction methods for MRI of tissues with short T2 or T2* (opens in a new tab)

  16. Investigation of Neonatal Pulmonary Structure and Function via Proton and Hyperpolarized Gas Magnetic Resonance Imaging

    … as the low proton-density, rapid T2* relaxation time of the lung parenchymal tissue, and inherent physiological motion in the chest. Recent developments in radial ultrashort echo time (UTE) MRI have in part overcome these issues. In addition, there has been much progress in techniques for …

    wustl Repository record for Investigation of Neonatal Pulmonary Structure and Function via Proton and Hyperpolarized Gas Magnetic Resonance Imaging (opens in a new tab)

  17. Optimierung und Evaluierung alternativer Methoden der Magnetresonanzangiographie

    … EKG getriggerten 3D flussabhängigen Fast Spin-Echo (FSE) MRA. Zur QISS-MRA existierten zu dieser Zeit lediglich initiale Studienergebnisse bei 1,5 T, während Daten zur Anwendung bei 3 T weitgehend fehlten. Die erste Pilotstudie zur QISS-MRA diente somit zunächst der generellen …

    fu-berlin Repository record for Optimierung und Evaluierung alternativer Methoden der Magnetresonanzangiographie (opens in a new tab)

Page 1 of 2