Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 12 of 12 for “"ultrasonic flow meter"”.
-
Optimisation of an Ultrasonic Flow Meter Based on Experimental and Numerical Investigation of Flow and Ultrasound Propagation
… to optimise the shape of a coaxial transducer ultrasonic flow meter. The technique uses separate numerical simulations of the fluid flow and the ultrasound propagation within a meter duct. A new flow meter geometry has been developed, having a significantly improved (smooth and monotonic) …
-
Ultrasonic Flow Measurement for Pipe Installations with Non-Ideal Conditions
… aspects of water resource management is that of flow measurement. Accurate flow measurement data is needed to effectively manage any water distribution system, whether for culinary or irrigation use. In order to successfully and accurately measure water flow in pipes, it is recommended that a …
-
Comparison of Selected Differential Producing, Ultrasonic, and Magnetic Flow Meters
Flow meters are used to measure flow accurately. There are many different flow meters and it is necessary to know which will function best for specific situations. A wide variety of flow meters were selected for the study to assist in showing that each flow meter has its tradeoffs. The selected …
-
Cavitation and Bubble Formation in Water Distribution Systems
… visual observation of bubbles, an inline turbidimeter, an ultrasonic flow meter, and an inline total dissolved gas probe were used to track the phenomenon. All four measurements confirmed that gaseous cavitation was occurring within the experimental distribution system, even at pressures up to 40 …
-
'n Ondersoek van die hoër-dinamiese funksies van die hart by bokke en konyne
… investigation was to use the technique of blood flow measurement in order to assess the higher dynamic functions of the heart in rabbits and goats. Rabbits and goats of different species have been used in this investigation . Parameters, for example the electrocardiogram, phonocardiogram, blood …
-
In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop
… restore the native valve’s vital unidirectional flow regulation. Therefore, artificial heart valve (AHV) research is of very high importance. Previous research studies have provided substantial input in the realm of AHV design relative to durability, thrombotic and hemolytic potential, and …
-
Development of a Low-Cost Ultrasound Flow Sensor
… a promising alternative; however, existing gas flow and composition sensors are typically too expensive for large-scale deployment in decentralized settings. This thesis presents the design, implementation, and evaluation of a low-cost transit-time ultrasonic flow meter intended for biogas …
-
Αποτελεσματικότητα της μειωμένης δόσης θρομβόλυσης σε συνδυασμό με αντιθρομβωτική αγωγή σε πειραματικό μοντέλο πρόκλησης θρόμβου
… allocated under continuous electrocardiogram and ultrasonic flow meter monitoring to one of the following groups: Group A) half-dose tenecteplase (2000IU); Group B) Full dose tenecteplase (5000IU); Group C) saline only. All animals received 60IU heparin and antiplatelet agents. The follow-up was …
-
Modeling power failures in deep-level mines to assist with emergency dewatering planning
… during physical investigations (pump tests and ultrasonic flow meter readings) and digital investigations (data) to ensure the simulation components could replicate real-world operating conditions to within a mean absolute error of 5%. Mine A determined that a 48-hour period would be sufficient …
-
IN VITRO VISUALIZATION OF PEDIATRIC SIZED MECHANICAL HEART VALVE PERFORMANCE USING AORTIC ROOT MODEL IN MOCK CIRCULATORY LOOP
… study is to better characterize and assess the flow field characteristics of a pediatric sized mechanical heart valve using flow visualization techniques in a mock circulatory loop. The mechanical heart valve chosen for this research was a size 17 mm Bjork-Shiley tilting disc valve, as this is a …
-
SmartInhaler : A Platform for Measurement of Inhaler Usage in Asthma Patients
… behavior and tracking of outdoor air quality parameters. SmartInhaler consists of an attachment to Metered Dose Inhalers (MDI) developed as a con gurable platform with an aim to measure patient ad- herence to asthma control medication. The attachment is designed to track the parameters associated …
-
Energetické hodnocení systémů TZB
Diplomová práce se zabývá energetickým hodnocením stávajících budov sportovně-rekreačního firemního areálu v Brušperku. K tomuto účelu uvádí porovnání vybraných druhů paliv, co by zdroje energie pro vytápění z hlediska ekonomického i jejich dopadu na životní prostředí. Dále uvádí přehled platné …