Size Exclusion Chromatography of Poly(2-ethyl-2-oxazoline) Homopolymers and Poly(ethylene oxide)-b-Poly(2-ethyl-2-oxazoline) Copolymers
… by SEC using multiple detectors. Both a universal calibration method and light scattering were used to determine molecular weights and molecular weight distributions. The solvent was N-methylpyrrolidone that contained 0.05M LiBr used to minimize interactions among the polymers and …
-
Applications of infrared spectroscopy to agricultural and food products
… In addition, the potential of using a single universal calibration to measure degree of degradation of frying oils or blend level of blended biodiesels, respectively, was evaluated in the studies. The first study shows that increased absorption due to a longer path length (4 mm) slightly …
-
Characterization of TDI-HEMA homopolymer prepared via an immiscible solvent system. Synthesis and investigation of oligodichloroketene
… part is subdivided into two areas. First a "Universal" calibration curve for gel permeation chromatography (GPC) was construc-ted using different molecular weight standards of PMMA and MMA-HEMA co-polymers. By measuring the viscosity of the different molecular weight solutions and calculating …
-
Solution properties of polymers.
… weights were used to obtain a conventional calibration curve for GPC. Another five polystyrene standards were used to obtain a universal calibration curve. By use of both calibration curves and the chromatogram of polymer sample from GPC, the number-average molecular weight, M¯n, and …
-
Dilute solution studies of molecular weight distributions of nitrocellulose, modified lignins and PMMA graft polymers
… of long chain branching were found to obey the universal calibration analytic scheme of GPC.
-
The molecular weight and etheral oxygen analysis of coal derived asphaltenes and preasphaltene samples.
… weight fractions, both the log MW and the Benoit universal calibration plots were constructed for each polymer system. None of the calibration plots for the polymer systems were colinear with the calibration plots constructed for the coal derived asphaltenes and preasphaltenes. Therefore, none of …
-
CFD Analysis of Viscosity Effects on Turbine Flow Meter Performance and Calibration
… using these models in order to create multiple calibration curves that show the response of the flow meter under various conditions. Each calibration curve consists of running a series of simulations at a range of flow rates for a particular fluid. The calibration curves for a variety of …
-
Factors influencing precision and accuracy of a carbon-in ash monitor
… are heterogeneous and need to be ground for the calibration of the carbon-in-ash-monitor. Homogeneity of fly ash is the most important factor to affect the precision and accuracy of the carbon-in-ash monitor. A sample preparation procedure was standardized to control sample density and to …
-
Novel high performance thermosetting polyimides
… determined by gel permeation chromatography (Universal Calibration). Successful molecular weight control was achieved using the reactive endgroups with imide oligomers synthesized with <Mp> values of 2,000 to 15,000 g/mole. The phenylethyny] and phenylmaleic endgroups permitted sufficient flow …
-
Synthesis and Characterization of Polymer Grafted Nanoparticles
… their respective diffusion coefficients. A calibration curve was generated correlating diffusion coefficients with polymer molecular weights. The reliability of the calibration curve was tested by comparing the molecular weights from DOSY to SEC from synthesized polymers. The accuracy of …
-
Synthesis and characterization of polyelectrolytes and aqueous latices
… molecular weight of the polymer is known. The universal calibration method has been proven valid for poly(acrylamide-co-sodium acrylate) using nonionic polyacrylamide standards. The correlation of elution volume shift with the content of ionic groups has been found, from which the molecular …
-
Stress metrology and thermometry of AlGaN/GaN HEMTs using optical methods
… thermometry methods require an extensive calibration process for each device investigated. To improve the implementation of micro-Raman thermometry, a method was developed which offers both experimental simplicity and high accuracy in temperature results utilizing a universal calibration …
-
The atom field ion microscope: Fundamental principles of operation
… theoretically and experimentally. A universal calibration procedure for relating the measured flight times to actual mass-to-charge ratios is established. This simple procedure, independent of the Atom Probe's particular operating parameters, only requires measurement of the applied …
-
Long Range Polymer Chain Dynamics Probed with Pyrene Excimer Fluorescence
… linear to branched. This study established a universal calibration curve from the absolute value of IE/IM plotted as a function of <k>, the aveage ate constant of excimer formation.
-
Calibrating the Long-Range Backbone Dynamics of Polymers in Solution Using Two Different Models
… The resulting equations were used to construct a calibration curve against which the dynamics of other polymers could be compared. This represents a great step forward as previous calibration curves were limited to a single solvent in which the benchmark polymers were soluble. Additionally, Nblob …
-
Adaptation of neutron safeguards measurements for the front-end of the modern nuclear fuel cycle
… Previous passive neutron UF₆ measurements found calibrations directly correlating total counts (Singles) to ²³⁵U mass and coincidence counts (Doubles) to enrichment were sensitive to UF₆ distribution and ²³⁵U/²³⁴U ratio. The proposed enricher-specific calibrations to reduce uncertainty from these …