Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 276 for “"universal testing machine"”.
-
An experimental interface of a microcomputer with a Vega Universal Testing Machine to retrieve data on test specimens
… an inexpensive interface between the Vega universal testing machine and a Commodore-64 microcomputer. Also, to develop a computer program that will store and retrieve pertinent information about the metallurgical properties of tensile specimens (i.e., modulus of elasticity, Brinell Hardness …
-
Development and Validation of a Single-Camera Video Extensometer
Mechanical testing is used to estimate the properties of materials and constructs. A video extensometer is a common measurement device in mechanical testing which uses a video camera to track fiducial markers on a specimen. This work presents the development and validation of a custom video …
-
Influence of a 3-step disinfection procedure on dentin bond strength
… mounted parallel to a bond shearing device on a universal testing machine (Instron) and randomly divided into 2 groups. In Group I (n=30), specimens were treated with chlorhexidine, tubulicid red, and sodium hypochlorite before dentin bonding, following the manufacturer's instructions for All …
-
Evaluation of Shear Bond Strength of Two Resin-Modified Glass-Ionomer Cements
… parallel to the bond shearing device on the universal testing machine (Instron). For Group I samples (Rely-X, n=15), the powder and liquid were measured and adjusted to achieve a ratio of 1.6 and mixed for 30 seconds as recommended by the manufacturer. For Group II (Fuji-Cem, n=18), the …
-
Application of analytical instruments in epoxy resin characterization
… elevated temperature viscometer (ETV), and the universal testing machine were used in this study to develop cure models for an amine cured epoxy. In this study, new methods based on differential analysis and least squares regression of DSC data are developed. This new method was found to be more …
-
An experimental investigation of mixed-mode fracture I/II/III of PMMA and aluminium 7075-T6
… To apply mixed-mode I/II/III loading using a universal testing machine such as an Instron Digital 8504 Servo Hydraulic Machine, a pair of novel grips were designed and manufactured; this design was awarded the Innovation Patent No 2008101040. Also to measure three-dimensional crack opening …
-
Evaluation of Two Surface Treatments and Two Composite Resins in the Repair of Fractured Veneered Stainless Steel Crowns
… and Dura. The original veneers were loaded in a universal testing machine to the point of fracture. The fractured surfaces were treated with aluminum oxide air particle abrasion or roughened with a diamond bur and restored with Herculite XRV Unidose composite or Filtek Z250 composite. The crowns …
-
Edge Chipping Resistance and Flexural Strength of Polymer Infiltrated Ceramic Network and Resin Nano Ceramic Materials
… degree sharp conical indenter was mounted on a universal testing machine and the specimens edge was positioned in distances varying from 0.1mm to 0.7mm horizontally from the indenter tip. Two edge chipping tests were performed per sample at a crosshead speed of 0.1mm/min and the critical force …
-
Mechanical Properties of a Dental Adhesive Modified with Polymer-Conjugated Penicillin Additives
… (MTBS) of groups (n=20) was quantified using a universal testing machine after incubation in deionized water (DW) for 24h or 4mo. Hourglass-shaped specimens (1mm x 2mm x 1mm) of each group (n=10) were subjected to tensional strain using a universal testing machine to determine the ultimate …
-
Development of Experimental and Finite Element Models to Show Size Effects in the Forming of Thin Sheet Metals
… the effects demonstrated by the experiment. A universal testing machine (UTM) was used to form aluminum and copper of varying thicknesses (less than 1mm) into a hemispherical dome. A stereolithography additive manufacturing technology was used to fabricate the punch and die from a UV curing …
-
The Effect of Sodium Hypochlorite on Nickel Titanium Rotary Instruments and its Effect on Resistance to Fracture
… files at a 30 degree angle at 350 rpm in a universal testing machine. Time to fracture was recorded and analyzed by a two-way ANOVA. Within both file types, there was a decreased time to fracture with increased immersion time in sodium hypochlorite. K3 files required an average of 327 …
-
Bonding Orthodontic Brackets to Stainless Steel Crowns
… + Transbond. Bond strength was tested using a universal testing machine. Both aluminablasting and diamond bur abrasion surface preparation techniques, when used in conjunction with metal primer and Assure bonding resin, reached clinically acceptable bond strength values (9.05 and 9.30 MPa, …
-
Long-term stability and resistance to fracture: Different abutments of the SIC implant system in the artificial mouth
… were later tested for fracture strength in a universal testing machine. The remaining 8 samples of the group were directly tested for fracture strength.<br><br>Results<br>All samples exposed to the 5-years artificial aging survived except of six samples in one group (Group 1). The surviving …
-
Orthodontic Bracket Bond Strength Using Self-Etching Primer With or Without Pumice or Acid Etch Pretreatment
… Debonding force was measured with an Instron universal testing machine. A two-way ANOVA comparing the four groups indicated that there was a significant difference in debonding force (P = 0.001). The SEP without prior pumicing group (17.69 ± 7.18 MPa) was statistically different from the SEP …
-
Effect of refrigerant spray on orthodontic composite resin-bracket debond strength and associated adhesive remnant index
… Bracket shear debond strength was tested with a universal testing machine and ARI scores assessed. Results showed no statistically significant difference for shear debond strength or ARI score as a function of refrigerant spray usage. Statistically significant differences were shown for shear …
-
The Effect of Pre-Cure Bracket Movement on the Shear Bond Strength of Metal Brackets
… Debonding force was measured with an Instron universal testing machine. Results were analyzed by ANOVA. Weibull survival analysis was used to determine the force required to produce a 5% bracket failure rate. Differences in the Adhesive Remnant Index (ARI) were analyzed by chi-square. No …
-
Effect of Air-Abrasion on the retention of zirconia ceramic crowns luted with different cements before and after artificial aging
… air-abraded (50 μm alumina, 0.25 MPa) or left as-machined equally. The crowns were luted with zinc phosphate cement, glass ionomer cement, or composite resin, subgroups were stored in 37° water bath either for 3 days or for 150 days with additional 37,500 thermal cycles (5°-55°) and 300,000 cycles …
-
Effects of temperature on the tensile strength and elastic modulus of composite material.
… (45/0/-45/90)s and (45/90/-45/0)s. An instron universal testing machine with 20,000 lb maximum load capacity was used to apply the uniaxial tensile loading. A Marshall clamshell furnace was used for maintaining the elevated temperatures. Results of the investigation indicate that ultimate …
-
Multiscale Optimization of Weav3D Lattice-Reinforced Composites for Lightweight Structural Design
… experimentally characterized through mechanical testing on a universal testing machine (UTM), with strain fields measured using Digital Image Correlation (DIC). These validated properties served as inputs to a computational optimization framework using Altair HyperStudy for parameter exploration, …
-
Flexural strength and shear bond strength of self-etching/self-adhesive resin luting agents
… that are superior to the newer so-called “universal” self-etching/self-adhesive resin luting agents. However, recent reports indicate that some properties of these new luting agents have been improved, approaching those of the traditional etch and rinse resin luting agents. The objective of …
Page 1 of 14