Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 20 for “"variable flip angle"”
-
Optimized Variable Flip Angle Methods for Single Pool MRI Relaxometry
… contrary, many gradient echo techniques, such as Variable Flip Angle (VFA), Driven Equilibrium Single Pulse Observation of T1/2 (DESPOT), Muti-Parametric Mapping(MPM), etc, have been developed to infer tissue MR properties in clinically feasible times. However, a consensus regarding the accu-racy …
-
Optimization of the measurement sequence used for functional Fourier Decomposition Magnetic Resonance Imaging of the human lung at 1.5 Tesla
… parenchyma and the restriction of the utilized flip angles, due to specific absorption rate (SAR) limitations. To achieve the necessary improvements, advanced techniques were used, specifically, (utra-)fast bSSFP, two speed variablerate selective excitation (VERSE) pulses and variable flip angle …
-
Novel Deep Learning Methods for Enhanced MRI Acquisition and Reconstruction
… MR sequences in self-learning MRI. Optimized variable flip angle schemes for 3D Fast Spin Echo imaging are identified that balance signal-to-noise ratio (SNR) and the point-spread function. In vivo evaluations at ultra-high field demonstrate that these optimized schemes substantially reduce …
-
Advanced Preclinical Cardiac MRI of Heart Diseases
… part focuses on evaluating and validating the variable flip angle (VFA) T1 sequence with different hardware settings using phantom and in vivo on the 9.4T Bruker MRI. Then, in the second part, the validated VFA T1 sequence was used with MRI contrast agent manganese, a calcium analogue, to …
-
Novel Body Magnetic Resonance Imaging Techniques
… and T2) for tissue characterization.A radial "variable flip angle" Steady-State Free Precession (SSFP) technique with slice profile correction was also developed to obtain fast estimation of another parameter, i.e. the T1/T2 value. This method was developed as an alternative for fast parametric …
-
Longitudinal relaxation dynamics in white matter : experiments in NMR and MRI
… T₁ biasing effects during Look-Locker and Variable Flip Angle sequences. We evaluate sources of systematic error pertinent to MRI applications. Finally, we modify the canonical Bloch-McConnell equations describing two-pool relaxation to incorporate fractional-order derivatives. We examine a …
-
Toward advances in data acquisition and analysis for quantitative multi-contrast magnetic resonance imaging
… by up to 58%. Second, using fully sampled variable-flip angle raw data of the brain from healthy volunteers, we retrospectively accelerate the raw data by 8- to 36-fold and apply an untrained deep learning method with physics-based regularization to reconstruct the anatomical images while …
-
Robust Fat and Fluid Suppression in MR Imaging: Technical Developments and Advanced Clinical Applications
… from low SNR. Then, a multi-echo Dixon based variable flip angle TSE sequence was implemented for robust fat suppression with improved SNR and blood suppression, increasing the visualization of brachial plexus. The multi-echo Dixon method was later extended to single shot TSE (SShTSE) sequence …
-
Development of Frequency-modulated Techniques for MRI of Fast Relaxing Spins
… study, T1 quantification of fetal skeleton with variable flip angle method and the development of a 3D adiabatic T1ho mapping method for steady state sequence were demonstrated and discussed. The potential application for SWIFT in the detection of tumor invasion, abnormalities or early …
-
Accelerated Magnetization Encoding for Reversibly Bound, Hyperpolarized Xenon in Molecular Host-Guest Systems
… novel method called CAVKA (combined approach of variable flip angle, keyhole, and averaging). It divides the signal domain into two parts, performs time-consuming signal averaging only for the nearly constant part while rapidly updating the second part that encodes image contrast along the …
-
Towards a relaxation-based MR-oximetry technique for the measurement of tumor hypoxia
… R1w and proton density at fraction (PDFF) to a variable flip angle, multi-echo gradient echo acquisition. In its conventional form, the Fat DESPOT model fits the magnitude of the MGRE signal. Fitting the complex signal would fully exploit the available data, potentially improving accuracy and …
-
Myocardial T1 Mapping Techniques for Quantification of Myocardial Fibrosis
… or the cyclic variation from the error of the variable flip angle (VFA) technique. Lastly, it is necessary to validate these techniques against the endomyocardial biopsy. </p><p>The work intends to validate several aspects of T1 mapping. Firstly, whether there is significant cyclic variation of …
-
Time-efficient methods for non-invasive brain blood flow imaging using arterial spin labelling MRI
… impact on the magnitude of the ASL signal. A variable flip-angle approach was also used to remove signal discontinuities and demonstrate a significant SNR improvement over conventional PCASL angiography.</p>
-
Hyperpolarized and thermally polarized quadrupolar noble gas nuclei studied by nuclear magnetic resonance spectroscopy and magnetic resonance imaging
… that allow for the implementation of variable flip angle FLASH imaging sequence in an excised, intact rat lung. Additionally, initial evidence suggests the T1 of 83Kr can differentiate between the regions of the lung (the trachea, the bronchi and bronchioles, and the alveoli), which …
-
Accurate and precise 3D T1 mapping of the human liver at 3T using widely available magnetic resonance imaging methods
… validated in vivo and used to find the optimal flip angles that resulted in the highest precision across a range of T1s and B1+ factors observed in the liver at 3 T.</p> <p>Using scanner-agnostic sequences together with corrections for the confounding factors, a variable flip angle 3D …
-
Three-dimensional T1 quantification techniques for assessment of cartilage quality using dGEMRIC
… of B1 inhomogeneities and slab profile flip angle variations in the 3D-LL data. From in vivo and phantom measurements the methods were shown to be reliable, with T1 results that agreed very well to gold standard two-dimensional inversion recovery (2D-IR). A 3D variable flip angle …
-
Development of Quantitative Myocardial Tissue Characterization
… in heart rate, spin-spin relaxation time (T2), flip angle, and off-resonance, which are known sources of error in MOLLI T1 values. Normal ranges for SASHA T1 values were established in a group of healthy controls and altered T1 values consistent with fibrosis were found in small study of …
-
Schnelle zweidimensionale Kartierung der longitudinalen Relaxationszeit T1 bei 1.5 Tesla, 3 Tesla und 7 Tesla mittels Magnetresonanztomographie
Die visuelle und damit subjektive Auswertung T1 gewichteter (longitudinale Relaxationszeit) oder T2 gewichteter (transversale Relaxationszeit) Schnittbilder gehören zur täglichen klinischen Diagnostik in der kardialen Magnetresonanztomographie (MRT). Für diese nichtquantitative Bildgebungsmethoden …
-
Surrogate MRI markers for chemodosimetry of doxorubicin with thermosensitive liposomes in tumors
… HPLC. MRI was performed at 3T. T1-mapping using variable flip angle was established before and after HT. Furthermore, dynamic mapping of T1 and the phase were performed during the experiment. Phase change (PC), T1- and T1-related parameters (absolute and relative changes), or areas under the …
-
Liposomal Drug Delivery Mediated by MR-guided High Intensity Focused Ultrasound: Drug Dose Painting and Influence of Local Tissue Transport Parameters
… of mild hyperthermia in larger volumes of variable shape that were typically encountered in the clinic. We approached this goal through a series of successive steps that addressed different aspects of mild hyperthermia treatment: 1) controlled heating to mild hyperthermia, 2) conformity of …