Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 39 for “"varus-valgus"”.

  1. Pain and function in knee osteoarthritis : are they related to local intrinsic factors?

    … Scale. Local intrinsic factors measured included Varus/Valgus Alignment, A/P Laxity, Proprioception, Knee Extension Strength by Bodyweight, Knee Flexion Strength by Bodyweight, and Knee ROM. Factors were recommended for inclusion in future research if they were significantly correlated with at …

    missouri Repository record for Pain and function in knee osteoarthritis : are they related to local intrinsic factors? (opens in a new tab)

  2. Finite element analysis of total knee replacement considering gait cycle load and malalignment

    … with smaller diameter was found to be the best. Varus/valgus malalignment redistributed the tibio-femoral contact force and stress/strain distribution in the distal femur. The difference between contact forces on the medial and lateral condyle decreased in the valgus malalignment condition. …

    wlv Repository record for Finite element analysis of total knee replacement considering gait cycle load and malalignment (opens in a new tab) Download file for Finite element analysis of total knee replacement considering gait cycle load and malalignment (opens in a new tab)

  3. Αγγειακή βλάβη στο τραυματικό εξάρθρημα του γόνατος: αναδρομική και νεκροτομική μελέτη

    … were studied: 1, hyperextension-anterior, 2, varus-valgus, 3, posterior and 4, rotatory-posterior. In the posterior and the rotatory-posterior dislocation the angle at the P2 segment of the popliteal artery was measured. In both types the angle was significantly different between the …

    greece Repository record for Αγγειακή βλάβη στο τραυματικό εξάρθρημα του γόνατος: αναδρομική και νεκροτομική μελέτη (opens in a new tab)

  4. Bone sawing and milling in computer-assisted total knee arthroplasty

    … 19 cadaveric femurs and tibias, I estimate the varus/valgus alignment variability associated with making two bone cuts to be ~0.8° SD for expert surgeons and ~1.4° SD for less experienced surgeons (taking √2 x the variability associated with a single cut at 95% confidence). In flexion/extension, …

    ubc Repository record for Bone sawing and milling in computer-assisted total knee arthroplasty (opens in a new tab) Download PDF for Bone sawing and milling in computer-assisted total knee arthroplasty (opens in a new tab)

  5. Validation of a Subject Specific Canine Hind Limb Model with Emphasis on an Anatomical Stifle

    … kinematics; a loading approximating a squat and varus/valgus rotation originating at the hip. The model provides an acceptable approximation of hind limb kinematics validating the modeling techniques used.

    umkc Repository record for Validation of a Subject Specific Canine Hind Limb Model with Emphasis on an Anatomical Stifle (opens in a new tab)

  6. Canine Femoral Deformities Causing Medial Patellar Luxation Characterized And Corrected Using Computed Tomography And Three-Dimensional Printing Technology

    … to excellent (ICC = 0.99). Seven femurs had varus/valgus (aLDFA) corrected to 95° and torsion (AA) corrected to 30°. The mean difference between the target and achieved was 1.29° (+/-3.58°, p = .085) for aLDFA and 3.43° (+/-5.21°, p = .012) for AA. The intraobserver ICCs for aLDFA and AA were …

    guelph Repository record for Canine Femoral Deformities Causing Medial Patellar Luxation Characterized And Corrected Using Computed Tomography And Three-Dimensional Printing Technology (opens in a new tab)

  7. Knee's Motion Path Relative to the Passive Coupled Kinematic Envelope

    … The coupled envelopes of internal/external (IE), varus/ valgus (VV), and anterior/ posterior (AP) motion and a neutral path were used to describe loaded lunges and a simulated walk cycle. The envelopes were created by manual manipulation to motion limits. Lunges with ±3.3 Nm IE torques and ±4.7 Nm …

    ku Repository record for Knee's Motion Path Relative to the Passive Coupled Kinematic Envelope (opens in a new tab)

  8. Computational Analysis to Evaluate the Effects of Knee Brace on Anterior Cruciate Ligament during Single-Leg Jump Landing

    … knee. The FE model was validated in quasi-static varus/valgus loading conditions by comparing the effective load reduction at the knee to experimental test data available. Single-leg jump landing simulations were then conducted in braced configuration by inputting the muscle forces and joint …

    waterloo Repository record for Computational Analysis to Evaluate the Effects of Knee Brace on Anterior Cruciate Ligament during Single-Leg Jump Landing (opens in a new tab)

  9. Combined Experimental and Statistical Model to Understand the Role of Anatomical and Implant Alignment Variables in Guiding Knee Joint Motion

    … component (PC) model was developed for the varus-valgus (V-V), internal-external (I-E) and anterior-posterior (A-P) envelope using twenty-one native cadaveric knees and the mode of envelope variations were identified. Subsequently, gait simulation was run on seventeen knees using the Kansas …

    ku Repository record for Combined Experimental and Statistical Model to Understand the Role of Anatomical and Implant Alignment Variables in Guiding Knee Joint Motion (opens in a new tab)

  10. Instantaneous axis of rotation for continuous human knee motion

    … tibial rotation, was related to the initial varus/valgus orientation of each knee. The anterior cruciate ligaments (ACL) of these same knees were subsequently severed, the knees were measured, and the motion analyzed. Differences in the motion characteristics of each knee were detected alter …

    nps Repository record for Instantaneous axis of rotation for continuous human knee motion (opens in a new tab)

  11. Tibiales Malalignment bei Mobile-Bearing-Prothesen

    … reasons. To assess the critical angle of tibial (varus / valgus) malalignment of knee prostheses in vitro, a simulator investigation was performed. Mobile-bearing- prostheses were implanted in a simulator with 1°-30 valgus- and varus malalignment as well as in neutral position. More extreme …

    lmu-germany Repository record for Tibiales Malalignment bei Mobile-Bearing-Prothesen (opens in a new tab)

  12. Precision and accuracy in computer-assisted total knee replacement

    … revision surgery. Errors of 3° to 5° in varus/valgus have been shown to cause poor outcomes. Based on 7 published studies (753 knees), I estimate the standard deviation (SD) of varus/valgus errors resulting from the current technique to be 2.6°. My long term hypothesis is that affordable …

    ubc Repository record for Precision and accuracy in computer-assisted total knee replacement (opens in a new tab) Download PDF for Precision and accuracy in computer-assisted total knee replacement (opens in a new tab)

  13. Analysis, Segmentation and Prediction of Knee Cartilage using Statistical Shape Models

    … results suggest distinct patterns of wear in varus, valgus, and neutral degenerative knees, and examination of contact regions during the deep knee bend activity further emphasizes these patterns. Segmentation results were achieved that were comparable if not of higher quality than existing …

    utk-theses Repository record for Analysis, Segmentation and Prediction of Knee Cartilage using Statistical Shape Models (opens in a new tab)

  14. Passive Frontal Plane Knee Joint Laxity Following Anterior Cruciate Ligament Reconstruction Within 6 Months to 5 Years

    … Frontal plane laxity was defined as the passive varus-valgus tibiofemoral angular excursion in response to a varus-valgus moment of 10 Nm. For controls, the knee with the greatest measured mean frontal plane laxity was used. The standard error of measurement and minimal detectable difference was …

    waterloo Repository record for Passive Frontal Plane Knee Joint Laxity Following Anterior Cruciate Ligament Reconstruction Within 6 Months to 5 Years (opens in a new tab)

  15. Simulation of the passive and active motions of the replaced knee - effect of malalignment and ligament strains

    … example, ligament imbalance was best detected by varus-valgus stability testing.</p> <p>In phase two of the research, computational finite element (FE) models were created for validation against the experimental test results. Using explicit FE analysis the experimental passive stability testing …

    soton Download PDF for Simulation of the passive and active motions of the replaced knee - effect of malalignment and ligament strains (opens in a new tab)

  16. The Effects of Tibiofemoral Conformity on the Kinematic Freedom of Revision Total Knee Arthroplasty Systems

    … physiological simulation. Results The change in varus-valgus (VV) motion with an increased IE torque was minimal for all three systems. However, an increased IE torque showed an increase in IE rotational motion for the ATTUNE® Revision knee compared to the NexGen® LCCK and Vanguard® 360 Revision …

    ku Repository record for The Effects of Tibiofemoral Conformity on the Kinematic Freedom of Revision Total Knee Arthroplasty Systems (opens in a new tab)

  17. Assessing Stability of the Knee In Vitro Using Envelope Normalized Kinematics and Principal Component Analysis

    … for anterior-posterior, internal-external, and varus-valgus kinematic directions. The coefficient matrix was used to score five implanted knees. Statistical analysis showed that there was no difference between natural and implanted knees when looking at the position of the kinematics relative to …

    ku Repository record for Assessing Stability of the Knee In Vitro Using Envelope Normalized Kinematics and Principal Component Analysis (opens in a new tab)

  18. Wear of a total ankle replacement

    … technique or failure to correct existing natural varus/valgus deformity. TAR malalignment can result in instability, deformity and is associated with increased wear and higher failure rates. Good alignment is considered instrumental for long term success. The aim of this research was to develop …

    whiterose Download PDF for Wear of a total ankle replacement (opens in a new tab)

  19. Assessing the performance envelope of total knee replacement : an explicit finite element study

    … In the 2<sup>nd</sup> study, the influence of varus/valgus knee on the performance of TKR was stimulated by offsetting the point of application of the axial load either medially or laterally. Medial eccentric loading was the most destructive for the TKR particularly when the collateral …

    soton Download PDF for Assessing the performance envelope of total knee replacement : an explicit finite element study (opens in a new tab)

  20. Finite Element Analysis of the Proximal implanted Tibea in relation to implant loosening

    … influence on implant loosening. The effect of varus-valgus and antero-posterior angles on the cancellous bone stress at the bone-implant interface was examined by means of finite element analysis. The lowest stress was obtained when the tibial tray was orientated in values. Moreover, the larger …

    soton Download PDF for Finite Element Analysis of the Proximal implanted Tibea in relation to implant loosening (opens in a new tab)

Page 1 of 2