Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"venous oxygenation"”

  1. MAGNETIC RESONANCE IMAGING OF CEREBRAL VENOUS OXYGENATION

    Cerebral venous oxygenation (Yv) is an important index of the brain’s oxygen metabolism, and has found clinical utility in various diseases, such as multiple sclerosis and Alzheimer’s disease. Traditionally, positron emission tomography (PET) with 15O-labeled radiotracers was considered the gold …

    jhu Repository record for MAGNETIC RESONANCE IMAGING OF CEREBRAL VENOUS OXYGENATION (opens in a new tab)

  2. Magnetic Resonance Imaging of Cerebral Venous Oxygenation

    Cerebral venous oxygenation (Yᵥ) is an important biomarker for brain diseases. My dissertation consisted of two studies. The first study aims to investigate the regional Yᵥ in hypertension. Hypertension is known to cause cerebral hypoperfusion and cortical atrophy but its impact on Yᵥ is not yet …

    utswmed Repository record for Magnetic Resonance Imaging of Cerebral Venous Oxygenation (opens in a new tab)

  3. Regional oxygenation in cardiac surgery. Influence of temperature, pump flow and insulin

    … in vital organs after cardiac surgery. Regional venous oxygenation reflects oxygen supply/demand balance and marked regional deoxygenation occurs during cardiopulmonary bypass. This thesis addresses two important perspectives of cardiopulmonary bypass (CPB): 1. Central and regional oxygenation, …

    goteborg Repository record for Regional oxygenation in cardiac surgery. Influence of temperature, pump flow and insulin (opens in a new tab)

  4. Development and Testing of an Implantable Perfusion and Oxygenation Sensor for Liver Transplant Monitoring

    … to measure perfusion changes, arterial oxygenation and venous oxygenation in the parenchyma of the liver tissue and the supplying vessels. Light at three different wavelengths (735-, 805- and 940-nm) is shined on the tissue and the diffuse reflectance is collected via a photodetector. …

    tamu Repository record for Development and Testing of an Implantable Perfusion and Oxygenation Sensor for Liver Transplant Monitoring (opens in a new tab)

  5. Applications of parallel radiofrequency transmission to ultra-high-field magnetic resonance imaging

    … (TRUST) that measures venous oxygenation.</p> <p>The ASL study demonstrates that labelling efficiency can be improved by the incorporation of pTx static shimming in the labelling pulses, but indicates that the temporal SNR does not yet exceed optimised 3 tesla protocols …

    oxford Repository record for Applications of parallel radiofrequency transmission to ultra-high-field magnetic resonance imaging (opens in a new tab)

  6. Physiological imaging and improved task design for the assessment of episodic memory using blood oxygenation level-dependent functional magnetic resonance imaging

    … benefits of including cerebral blood flow and venous oxygenation estimates in general linear models for fMRI data in cognitively healthy adults and MCI patients. Furthermore, the advantages of non-parametric permutation testing and physiological noise modelling were explored. The third project …

    bristol Repository record for Physiological imaging and improved task design for the assessment of episodic memory using blood oxygenation level-dependent functional magnetic resonance imaging (opens in a new tab)

  7. Measurement of Cerebral Metabolism and Vascular Function with Magnetic Resonance Imaging

    … This method uses the Fick principle of arterio-venous difference for the calculation of CMRO2.and employs phase-contrast MRI for quantitative blood flow measurement and T2-relaxation-under-spin-tagging (TRUST) MRI for venous oxygenation estimation. During this thesis, I conducted several …

    utswmed Repository record for Measurement of Cerebral Metabolism and Vascular Function with Magnetic Resonance Imaging (opens in a new tab)

  8. Blood Oxygenation Quantification In The Human Fetal Brain Using Susceptibility Weighted Imaging And Mapping

    BLOOD OXYGENATION QUANTIFICATION IN THE HUMAN FETAL BRAIN USING SUSCEPTIBILITY WEIGHTED IMAGING AND MAPPING by BRIJESH KUMAR YADAV May 2018 Advisor: Dr. E. Mark Haacke Major: Biomedical Engineering with Dual title in Biomedical Imaging Degree: Doctor of Philosophy Oxygen is a source of life for us …

    wayne-thes Repository record for Blood Oxygenation Quantification In The Human Fetal Brain Using Susceptibility Weighted Imaging And Mapping (opens in a new tab)

  9. Applicability of Quantitative Functional MRI Techniques for Studies of Brain Function at Ultra-High Magnetic Field

    … Functional MRI (fMRI) commonly uses the blood oxygenation level dependent (BOLD) contrast to detect functionally induced changes in the oxy-deoxyhaemoglobin composition of blood which reflect cerebral neural activity. As these blood oxygenation changes do not only occur at the activation site …

    qucosa-diss Repository record for Applicability of Quantitative Functional MRI Techniques for Studies of Brain Function at Ultra-High Magnetic Field (opens in a new tab)

  10. Quantitative Susceptibility Mapping in Ischemic Stroke: Cerebral Veins, Tissue, and Microbleeds

    … to various applications.Tissue and draining vein oxygenation level in the brain is a prominent parameter in determining the severity of ischemia. Due to its sensitivity to deoxyhemoglobin, QSM provides a quantitative measure of brain tissue and venous oxygenation. QSM can also distinguish between …

    alberta Repository record for Quantitative Susceptibility Mapping in Ischemic Stroke: Cerebral Veins, Tissue, and Microbleeds (opens in a new tab)

  11. Quantative Evaluation of Myoglobin and Hemoglobin Oxygenation during Contraction using Near-Infrared Spectroscopy

    … procedure whose signal reflects tissue oxygenation. We hypothesized however that near-infrared spectroscopy (NIRS) measures of hemoglobin and/or myoglobin 02 saturation do not reflect the venous oxygen saturation because of the Hb and Mb contributions to the NIRS signal. A computational …

    ohiolink Repository record for Quantative Evaluation of Myoglobin and Hemoglobin Oxygenation during Contraction using Near-Infrared Spectroscopy (opens in a new tab)

  12. Novel Methods for the Detection of Functional Brain Activity using 17O MRI

    … blood flow (CBF). Fick’s principle of arteriovenous oxygen difference [1] connects CMRO2 and CBF via the measure of oxygen extraction fraction (OEF). The main goal of this work is to achieve non-invasive measures of OEF based on magnetic resonance imaging (MRI) to quantify CMRO2 allowing …

    liege Repository record for Novel Methods for the Detection of Functional Brain Activity using 17O MRI (opens in a new tab)