Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"ventilation requirements"”.

  1. VENTILATION REQUIREMENTS IN CIVIL DEFENCE SHELTERS

    The ventilation requirements for survival in a civil defence shelter was studied in this project. Test subjects, consisting of local people, were tested for their physiological and psychological responses in a crowded, warm and humid environment in a thermally environmental-controlled chamber. The …

    nus Repository record for VENTILATION REQUIREMENTS IN CIVIL DEFENCE SHELTERS (opens in a new tab) Download file for VENTILATION REQUIREMENTS IN CIVIL DEFENCE SHELTERS (opens in a new tab)

  2. FEASIBILITY ANALYSIS OF STEAM VENTILATION IN SUPERCAVITATION DESIGN

    … of supercavities often requires supplemental ventilation, traditionally by non-condensable gasses, as natural supercavitation occurs at relative speeds between the object and liquid medium that are infeasible for the device to reach without supercavitation itself. The aim of this research is …

    clemson Repository record for FEASIBILITY ANALYSIS OF STEAM VENTILATION IN SUPERCAVITATION DESIGN (opens in a new tab)

  3. Simulating energy efficiency in laboratory buildings

    … buildings are large consumers of energy. The ventilation requirements of these buildings mandate that large quantities of outside air be brought into the building. The advent of air-to-air heat recovery systems has been proven to significantly decrease the energy input needed to condition …

    iastate Repository record for Simulating energy efficiency in laboratory buildings (opens in a new tab)

  4. Modeling of HVAC Configurations for De-Carbonization in a Mid-Size Hospital

    … become cleaner. In terms of building type, high ventilation requirements and near continuous occupancy make healthcare facilities some of the highest energy users. HVAC equipment runs all day and night in these facilities with little change. Conventional HVAC equipment such as a boiler is proven …

    maryland Repository record for Modeling of HVAC Configurations for De-Carbonization in a Mid-Size Hospital (opens in a new tab)

  5. COMPACT SPACE-FOLDED MULTI-RESONATOR DUCT SILENCER WITH BROADBAND NOISE REDUCTION AND MINIMAL FLOW DISTURBANCE

    … importance due to the complex challenges of ventilation requirements imposed on the system. This research presents a compact, space-folded silencer which achieves broadband attenuation of noise in ducted applications. Making use of axial arrays of side- loaded resonators, this structure …

    rowan Repository record for COMPACT SPACE-FOLDED MULTI-RESONATOR DUCT SILENCER WITH BROADBAND NOISE REDUCTION AND MINIMAL FLOW DISTURBANCE (opens in a new tab)

  6. Performance-Based Framework for Assessing Thermal Comfort Conditions at the HUB on the University of Washington Campus

    … resource inputs. On average, building heating, ventilation, air conditioning, and cooling (HVAC) systems account for roughly 39% of the energy consumption in office buildings [1]. Additionally, studies suggest that the average American spends 90% of their time indoors [2], making the protection …

    washington Repository record for Performance-Based Framework for Assessing Thermal Comfort Conditions at the HUB on the University of Washington Campus (opens in a new tab)

  7. Sustainable use of inlet guide vanes to reduce energy consumption of main ventilation fans

    … has focused on energy saving techniques on main ventilation fans (MVFs). MVFs extract hot, humid air from underground operations, which induces fresh air via a downcast shaft. However, the operation of MVFs is an energy-intensive operation, with installations ranging from 1 MW to 10 MW. …

    nwu-za Repository record for Sustainable use of inlet guide vanes to reduce energy consumption of main ventilation fans (opens in a new tab)

  8. Characterizing swine finishing facility environment and ventilation management

    … facilities with automated feed, water, and ventilation systems. Air exchange is achieved through electrically powered fans and is critical for animal performance, health, and animal welfare. Ventilation requirements change rapidly throughout the growth cycle and are highly dependent on …

    iastate Repository record for Characterizing swine finishing facility environment and ventilation management (opens in a new tab)

  9. A Framework for Life of Mine Ventilation Planning with a Case Study of the Diavik Diamond Mine

    A ventilation planning framework with a focus on life-of-mine plans has been developed and was validated with a case study. The framework reconciles the mine production plan with the ventilation plan by creating design acceptability criteria, and from these, minimum airflow requirements for the …

    queens Repository record for A Framework for Life of Mine Ventilation Planning with a Case Study of the Diavik Diamond Mine (opens in a new tab)

  10. Multizone Modeling of Airborne Quanta Transmission and CO2-based Ventilation Designs for Assessing Indoor Exposures

    In indoor environments, ventilation is essential for diluting or removing contaminants, pathogens, excess heat, and moisture, thereby ensuring a healthy and comfortable space. The COVID-19 pandemic underscored the critical role of ventilation in controlling airborne respiratory infections indoors. …

    concordia Download PDF for Multizone Modeling of Airborne Quanta Transmission and CO2-based Ventilation Designs for Assessing Indoor Exposures (opens in a new tab)

  11. Optimization of HVAC control system strategy using two-objective genetic algorithm

    … supply C02 concentration (or minimum outdoor ventilation), reheat (or zone supply air temperature), and zone air temperature are optimized with respect to energy use and thermal comfort. The multi-objective genetic algorithm that is developed and validated using mathematic and simplified HVAC …

    ets-quebec Download PDF for Optimization of HVAC control system strategy using two-objective genetic algorithm (opens in a new tab)

  12. Developing an experimental system identification method to extract air flow rates from room temperature measurements

    … flow rates since this is the easiest way to meet ventilation and thermal requirements. However, HVAC energy usage can be reduced by minimizing these air flow rates while still meeting ventilation requirements. In order to achieve this, a tool capable of determining the air change rates on a …

    bu Repository record for Developing an experimental system identification method to extract air flow rates from room temperature measurements (opens in a new tab)

  13. Application of simulation techniques in development planning for caving methods

    … and mass excavation rates and scheduled ventilation requirements. The process of simulation was significant in enabling the optimization of development planning and equipment selection. There appear to be considerable opportunities for simulation of such planning aspects in mining. This …

    ubc Repository record for Application of simulation techniques in development planning for caving methods (opens in a new tab) Download PDF for Application of simulation techniques in development planning for caving methods (opens in a new tab)

  14. DESIGN, FABRICATION AND ANALYSIS OF AN AUXILIARY POWER UNIT ON A HEAVY-DUTY TRUCK TO POWER THE HVAC SYSTEMS OF THE TRUCK DURING DRIVER OFF-DUTY CONDITIONS

    … reached inside the systems and appropriate ventilation requirements were selected for safe operation of the system. Sound measurement tests were conducted to validate if the APU was actually an aid to the driver during rest times. The sound measurements were made in a real time simulated …

    mtu Repository record for DESIGN, FABRICATION AND ANALYSIS OF AN AUXILIARY POWER UNIT ON A HEAVY-DUTY TRUCK TO POWER THE HVAC SYSTEMS OF THE TRUCK DURING DRIVER OFF-DUTY CONDITIONS (opens in a new tab)

  15. A Method for Evaluating the Application of Variable Frequency Drives with Coal Mine Ventilation Fans

    … of controlling airflow for primary coal mine ventilation. With this method, the fan operates at a constant speed dictated by its motor design. The angles of the blades are adjusted to change the amount of airflow and pressure to meet ventilation requirements. Typically, the fan does not …

    vt Repository record for A Method for Evaluating the Application of Variable Frequency Drives with Coal Mine Ventilation Fans (opens in a new tab)

  16. Ventilation design strategy to meet future production requriements for a Saskatchewan potash mine

    … This thesis covers the design of a mine ventilation system that will meet the operating constraints of the post-expansion production requirements, the publishing of which is unique compared to typical potash mine ventilation practice, which has historically been based solely on field …

    queens Repository record for Ventilation design strategy to meet future production requriements for a Saskatchewan potash mine (opens in a new tab)

  17. Establishing Total Airflow Requirements for Underground Metal/Non-metal Mines based on the Diesel Equipment Fleet

    Traditionally, ventilation requirements for modern, mechanized underground mines have been based upon the power of the diesel equipment fleet, with a multiplier (determined from empirical data collected and compiled over a long period of time or required by regulations) being applied in order to …

    queens Repository record for Establishing Total Airflow Requirements for Underground Metal/Non-metal Mines based on the Diesel Equipment Fleet (opens in a new tab)

  18. A theoretical study on VOC source and sink behavior of porous building materials

    … levels, and for determining the optimum ventilation requirements for acceptable IAQ. This study has investigated theoretically VOC source and sink behavior of porous building materials. A novel analytical model was developed based on the fundamental theories of mass transfer mechanisms in …

    concordia Download PDF for A theoretical study on VOC source and sink behavior of porous building materials (opens in a new tab)

  19. Energy efficient achievement of indoor air quality and thermal comfort using mechanical ventilation heat recovery and solar-energy pre-heating

    … solar air heating technologies with a Mechanical Ventilation Heat Recovery (MVHR) system for pre-heating ventilation air to achieve energy efficiency and maintain Indoor Air Quality (IAQ) and thermal comfort in an institutional building. Key research gaps addressed include balancing IAQ with …

    cork Repository record for Energy efficient achievement of indoor air quality and thermal comfort using mechanical ventilation heat recovery and solar-energy pre-heating (opens in a new tab) Embargoed until 2026-12-31

Page 1 of 2