Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"very small currents"”.

  1. Ανάπτυξη συστήματος μικρορευστονικής (microfluidics) με ηλεκτροχημική ανίχνευση

    … a new inte¬grated circuit for the measurement of very small currents (1 pA – 1 nA) based on their integration through combination of a follower amplifier and an analog integrator. The high sensitivity of the circuit is utilized in microfluidic systems, where de facto the measured faradaic …

    greece Repository record for Ανάπτυξη συστήματος μικρορευστονικής (microfluidics) με ηλεκτροχημική ανίχνευση (opens in a new tab)

  2. Skyrmions and Biskyrmions in Magnetic Films

    … can exist at the nanoscale, be manipulated with very small currents, and be created by a number of different methods. This makes them attractive for use in potential computing applications. This work studies ferromagnetic skyrmions. In particular, it highlights our small contributions to the …

    cuny-grad Repository record for Skyrmions and Biskyrmions in Magnetic Films (opens in a new tab)

  3. A Novel Frequency Based Current-to-Digital Converter with Programmable Dynamic Range

    … ultra low-power circuits necessitates the use of very small currents. Frequently these currents need to accurately measured, but current solutions typically involve off-chip measurements. These are usually slow, and moving a current off chip increases noise to the system. Moving a system such as …

    utk-theses Repository record for A Novel Frequency Based Current-to-Digital Converter with Programmable Dynamic Range (opens in a new tab)

  4. The Use of an Energy Analyser for the Measurement of the Total Energy Distribution of Field-Emitted Electrons from Tungsten

    … with cylindrical symmetry, the measurement of very small currents of about 10-14 A, and the use of a.c. field desorption for the emitter cleaning. Effects seen during emitter cleaning were described. The analyser had three faults (a) the collector current was too small, (b) the lens effect at …

    aston Download PDF for The Use of an Energy Analyser for the Measurement of the Total Energy Distribution of Field-Emitted Electrons from Tungsten (opens in a new tab)

  5. Minimalizace chyb při měření velmi malých proudů

    Tato práce se zabývá metodikou měření velmi malých proudů řádově 10-8 - 10-14 [A] a chyb, které vznikají při tomto měření. V práci je kladen důraz na elektrickou vodivost izolačních materiálů a rozhraní elektroda – dielektrikum při nabíjení a vybíjení měřeného vzorku umístěného v co nejideálněji …

    brno-tech Repository record for Minimalizace chyb při měření velmi malých proudů (opens in a new tab)