Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"voltage angle"”.
-
On the use of the load flow concept to evaluate power system security
… a relationship between bus power changes and bus voltage phase angle changes. A stability criterion based on the ratio of load power increments to bus voltage angle changes is defined. Finally, the algorithm developed and the stability criterion are used to assess the security of three different …
-
Power System Control with Distributed Flexible AC Transmission System Devices
… sensitivities of power system quantities such as voltage magnitude, voltage angle, bus power injections, line power flows, and real power losses with respect to line impedance. These sensitivities enable us to identify and develop appropriate applications for the use of D-FACTS devices for the …
-
Impact of Renewables on Grid Strength, Transient Stability, and Grid Operation Characterization
… 3 describes an effort to study active power and voltage angle data on the Southern Company system in order to investigate voltage angle difference as an indicator of early event awareness due to stress on the system caused by power flow through an interface.</p>
-
Intelligent distribution fault location using voltage magnitude measurements
… These sensors allow the capture of fast-sampled voltage data such as frequency, voltage magnitude, and voltage angle measurements in a low-cost, easily deployable manner. Traditional fault location methods use both current and voltage data. Voltage monitoring devices only collect voltage data, …
-
Synchronized Measurement of Machine Rotor Angle and Its Application
The internal voltage angle of a generator is an important parameter that indicates the stability, both transient and steady-state, of the generator. This paper proposes a method of measuring and synchronizing the internal angle using a microprocessor and an optical encoder installed on the shaft of …
-
Bi-Directional Grid-Tied Power Converter with GPS Capability
… of this converter is that time-stamped grid voltage angle received via network communication channels has been used to synchronize the converter to the grid. Therefore, all grid-tied converters in a mi-crogrid with this development will not require line voltage sensing and phase-locked loops. …
-
CONTINGENCY ANALYSIS USING SYNCHROPHASOR MEASUREMENTS
… are investigated using current magnitude and voltage angle. These limits are applied to a rotating phasor chart. An algorithm which predicts sensitivity is applied in the off-line analysis in order to determine the buses that need to be monitored. An actual system with available real-time PMU …
-
Trajectory Tracking Wide-Area Control for Power Systems
… inverter is calculated to drive the local bus voltage angle toward a trajectory that tracks the angle of the center of inertia. The results of this endeavor indicate that trajectory tracking control can improve both transient and small-signal stability, while also increasing tuning flexibility. …
-
Adaptive out of step relay algorithm
A peninsular power company's extra high voltage (EHV) transmission grid and the rest of the country behave as a two machine system for the following two types of disturbances loss of a large generator in the southern region of the peninsular power company faults on the 500 kV interconnections …
-
Simplified Maximum Torque per Ampere Trajectory Tracking for Permanent Magnet Synchronous Machine Drives
… (MPE). MTPA control can be achieved by direct voltage control. Therefore, a simple direct voltage MTPA control strategy is suggested with a thorough insight analysis to define the control gains analytically, which simplifies the control ultimately and makes it more suitable for low-cost …
-
Wide-area monitoring and control utilizing PMU measurements for a system protection scheme
… time-synchronized high-resolution estimates of voltage and currents (both phase amplitude and angle) as well as frequency and rate of change of frequency. Such measurements, alternatively called synchrophasors, can provide visibility of a power system distributed over a wide geographical area …
-
High Accuracy Real-time GPS Synchronized Frequency Measurement Device for Wide-area Power Grid Monitoring
… and transmits calculations of frequency, voltage magnitude and voltage angle to the remote servers via the Internet. Compared with its commercial counterpart Phasor Measurement Unit (PMU), FDR provides less expensive version for networked high-resolution real-time synchronized. The …
-
Power Systems Analysis in the Power-Angle Domain
… power systems dynamic analysis in the power-angle domain has been hinted at by previous researchers, but this may be the first published document to develop detailed techniques by which entire power systems can be represented and solved in the power-angle domain. With the widespread …
-
Hybrid Asynchronous/Synchronous Pulse Width Modulation Technique for Permanent Magnet Synchronous Motor Drives in Traction Applications
… of PWM techniques for three-phase, two-level voltage source inverters (2L-VSIs), providing an in-depth comparative analysis of the commonly used PWM techniques based on experimental investigations. The selected PWM techniques are assessed based on key performance metrics, including output …
-
Specification, Placement, and Control of Fault Current Limiters In Power Systems
… systems is enhanced and the allowable range of voltage-angle differences is expanded during synchronization. The optimal placement of FCLs in a power system with a ring structure is also proposed. With this optimal placement, fault currents in any location can be limited, while the maximum …
-
Wide Area Power System Monitoring Device Design and Data Analysis
… study is to take a first in depth look at the angle data collected by FDRs. Different data conditioning techniques are proposed and tested before one is chosen. The chosen technique is then used to extract useable angle data for angle analysis on eight generation trip events. The angle …
-
Next Generation Frequency Disturbance Recorder Design and Timing Analysis
… the FDR provides high accuracy frequency, voltage magnitude and voltage angle data to the remote servers. Although the current FDR design is up to the standard in terms of the measurement accuracy and portability, it is of interest to further the research into alternative architectures and …
-
Small-signal dynamics in converter-permeated power systems : multi-machine interactions, probabilistic analysis, and variability quantification
… converter control approaches, which trackthe voltage angle at the connection point and output the specified power accordingly,will introduce significant challenges when they constitute high penetrations of thegeneration mixture of a power system. As such, grid-forming converter control …
-
State Estimation and Voltage Security Monitoring Using Synchronized Phasor Measurements
… to provide synchronized phasor measurements of voltages and currents from widely dispersed locations in an electric power grid. The commercialization of the global positioning satellite (GPS) with accuracy of timing pulses in the order of 1 microsecond made possible the commercial production of …