Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 37 for “"voltage gradient"”.
-
The Role of the Voltage Gradient in the Agarose Gel Electrophoresis of DNA
… during agarose gel electrophoresis (AGE) from voltage gradient are developed from the data of McDonnel (36) for electrophoresis in a 1.6% agarose gel. These equations represented the data well for DNA between 2 and 10 kilobase pairs (KBp) in length. A computer program, called GELSIM, which …
-
Novel conversion of waste activated sludge to Class A biosolids with support of electrokinetics
… The experiment, done at a lab scale used a low voltage gradient under 5V/cm and low concentrations of BioxyS, (organic, non-toxic agent that acts as a biocide) and ammonium salts. The reaction took place in a BioElectro reactor composed of two stainless steel electrodes and a lid comprising of …
-
Development of an electrokinetic method of dewatering and upgrading sludge to class A / excellent quality biosolids : comparison of aerobic and anaerobic municipal sludge
… primary and secondary sludge where the lower voltage gradient, conditioner and blower system were applied. No Fecal coliforms were detected after treatment in most of the EK cells. The highest log reduction of Salmonella spp. was achieved in the EK cell with anaerobic digested sludge, under …
-
A Vacuum Tube for an Electrostatic Accelerator
… discharge, and to study the voltage-gradient characteristics of short sections of the tube when they were evacuated to a low internal pressure.
-
Acoustic Tracking of Redband Rainbow Trout (Oncorhynchus myskiss gairdneri) in Lake Roosevelt (2015-2016), Evaluation of an Acoustic Receiver Array, and Low-Voltage Electroanesthesia for Tag Implantation.
… methods for achieving anesthesia such as low voltage electroanesthesia (LVEA). LVEA subjects fish to a continuous non-pulsed direct current to achieve anesthesia appropriate for tag implantation. Unlike chemicals fish are quickly anesthetized and recover from anesthesia instantaneously. My …
-
Correlation of electrical and thermal properties of building brick
… first power of the porosity. The fact that the voltage gradient necessarily adjusts itself to produce uniform current flow through the material makes no difference in the electronic component of conductivity since such a voltage gradient change does not alter the electronic resistance of either …
-
Numerical Simulations in Electro-osmotic Flow
… of electro-phoresis and EOF utilizing a varying voltage gradient. The velocity distribution and the effective diffusion were solved for analytically, for both a linear and non-linear voltage gradient, using the MWM and the creeping flow approximations. The resulting equations aid in optimizing …
-
Diagnosis of arcing in retaining rings of turbogenerators
… is sparking due to high field efects (or high voltage gradient across the contact junction) and the other is a make-and-break contact arcing owing to the presence of inductance in the system. Experiments performed to measure the contact resistance between the retaining ring and mild iron piece …
-
Efficiency of electro-osmosis in soft soils
… in a neutral soil. Under an electric potential gradient, these cations move. The solvated water molecules around them are thus attracted to the electrodes. With water drainage, soil consolidates, and be strengthened.A laboratory investigation and a fieldwork were performed to evaluate the …
-
Development of an algorithm for detection and classification of capacitor switching events
… events, such as wavelet transform coefficients, voltage gradient at the switching instant, inrush current, steady-state voltage rise, and reactive power support. Moreover, a library with common range of values for these parameters is used to improve the algorithm accuracy. For each identified …
-
Proposed laboratory investigation into electroosmotic dewatering of mine tailings
… pore fluid chemistry, degree of saturation, voltage gradient and electrode configuration. Additionally, electroosmotic dewatering of mine tailings has not been implemented on a large-scale possibly due to lack of developed procedure, difficult water removal, and lack of a commercially …
-
Comparative Study of Electrochemical Pretreatment of Sludge for Enhancing Green Energy Production
… 1.3 V/cm. Scaling up with an enhanced 3.4 V/cm voltage gradient for 60 minutes significantly increased sludge temperature, solids content, and organic compound solubilization. The SCOD/TCOD ratio in EC-pretreated sludge was 11 times higher than in raw sludge, demonstrating scalability. Phase 2 …
-
Electrokinetic Remediation of Organic Soil Polluted with Petroleum Products in Temperate and Cold Regions
… with toluene and exposed to a constant low DC voltage gradient. To optimize electrokinetic remediation, a daily injection of surfactant was conducted. The tests were carried out continuously over a period of four days without anolyte, and one day including electroosmotic discharge collecting …
-
Response of the self-potential method to changing seepage conditions in embankment dams
… the phenomenon of streaming potential: the voltage gradient induced by the flow of water through a porous medium. However, current standard methods of SP data interpretation do not provide information about soil properties and seepage flow rates required by geotechnical engineers to assess …
-
Effects of Curing Agents and Drilling Methods on CAF Formation in Halogen-Free Laminates
… test at 85 ºC, relative humidity of 85%, and a voltage gradient of 0.4V/µm. Time-to-failure for DICY-cured and phenolic-cured epoxy with laser drilled microvias and mechanically drilled vias were determined using the insulation resistance test. The failed coupons were cross-sectioned and …
-
Conductive Anodic Filament (CAF) Formation
… (PWBs) which occurs under high humidity and high voltage gradient conditions. The filament, a copper salt, grows from anode to cathode along the epoxy-glass interface. Ready and Turbini (2000) identified this copper salt as the Cu2(OH)3Cl, atacamite compound. This work has investigated the …
-
Electrokinetic stabilisation of soft clay
… at the Newcastle University to apply a constant voltage gradient of 50 V/m across a soil sample approximately 400 mm. The first stage involved testing of a ‘pure’ system with distilled water as the main pore electrolyte fluid supplied under zero hydraulic gradient conditions for periods of 3, 7 …
-
Development of a hybrid electrokinetic system for the simultaneous removal of heavy metals and PAHs from clayey soil
… connected to a DC power supply to achieve a voltage gradient of 0.3 V/cm. In order to avoid some negative impacts associated with electrokinetic processes, ion exchange textiles (IET) were incorporated into the system. Electrical parameters, pH, volume supplied and volume discharged were …
-
Negative Effects of Electroshocking Fish Embryos: Implications for Threatened and Endangered Fishes
… and most sensitive to DC electroshock (lethal voltage gradient causing 50% survival (LV-50) = 1.2 V/cm), followed by whitetail shiner Cyprinella galactura (1.77 mm; LV-50 = 5 V/cm) and spotfin chub (1.83 mm; LV-50 = 6 V/cm), which were similar in size and sensitivity. A strong relation between …
-
An experimental and analytical study of electrokinetic consolidation
… electrokinetics, self-weight, and hydraulic gradient) were performed and reported. For comparing soil behaviour under electrokinetics with self-weight consolidation, the electrode configuration of closed anode and open cathode (the anode at the base of the cathode at the top of the soil) was …
Page 1 of 2