Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"voltage inputs"”.
-
SADDAS; a self-contained analog to digital data acquisition system.
… Digital Data Acquisition System, converts analog voltage inputs to formatted BCD (binary coded decimal digital magnetic tape. SADDAS consists of a 16 channel multiplexer, a 17 bit (4 digits + sign) 40 microsecond analog to digital converter, a 512 byte 8 bit core memory, a 30 IPS (inches per …
-
Near-Optimal Control of Atomic Force Microscope For Non-contact Mode Applications
… representing the dynamics between piezoelectric voltage inputs and cantilever probe positioning, including nonlinear surface interaction forces, for atomic force microscopes (AFM) is considered. By considering a relatively large cantilever stiffness, singular perturbation methods reduce …
-
Developing a Non-Invasive Compressive Load Osteoarthritis Model
… was calibrated and validated to ensure that voltage inputs would output the correct loads imparted to the knee joint. Once the device was calibrated, rat cadaver testing was done until ACL rupture was confirmed on a cadaver. The implications of the machine working are that the ACL rupture …
-
Software Modelling For Real World Faults On AC Transmission Protective Systems Analysis And Effects
… Corporation (NERC) include: 1. AC current inputs (Current Transformers, cables, aux CTs, etc)2. AC voltage inputs (Voltage Transformers, cables, aux VTs, etc) 3. Control voltage (Batteries, chargers, cables, etc) 4. Protective relays (numerical, sold state, and electromechanical) 5. …
-
Micromachined Differential Scanning Calorimeter for Cellular Differentiation and Metabolism Monitoring
… cells and white blood cells (lymphocytes). Step voltage inputs were applied to the DSC while the response of the RTD to temperature was monitored. The results from initial testing showed a detectable increase in chamber temperature of 0.375ºC for the JM-1 liver cells. Further analysis was …
-
Design and development of high step-up single-switch DC/DC converters for micro-inverter applications
… high-step-up DC–DC converters to interface low-voltage inputs with high-voltage DC buses. However, traditional converters such as boost and buck-boost require extreme duty cycles to achieve high voltage gains. For instance, achieving a gain ratio of 8 to 10 requires a duty cycle of 0.87 to 0.9. …
-
Microchip Analysis of Temperature and Humidity’s Effect on the Performance of Supply Voltage and Age
… and precisely as well as the microchip voltage inputs and outputs. These results suggest that all values of VOH, VOL, VIH, VIL, and power consumption can be read, calculated, and recorded onto a DOE Analysis excel sheet to observe the results and produce the required graphs of …
-
Nonlinear Model-Based Control for Neuromuscular Electrical Stimulation
… to deal with this uncertainty. We consider here voltage inputs without and with saturation. For the latter, the Nussbaum gain is applied to handle the input saturation. The last two control strategies are based on a more refined NMES model that accounts for the muscle activation dynamics. The …
-
Current Based Fault Detection and Diagnosis of Induction Motors. Adaptive Mixed-Residual Approach for Fault Detection and Diagnosis of Rotor, Stator, Bearing and Air-Gap Faults in Induction Motors Using a Fuzzy Logic Classifier with Voltage and Current Measurement only.
… and the system requires only current and voltage inputs to operate. Validation results indicate that the system performs well under a range of load torques and different coupling methods proving it to have significant potential for use in industrial applications.
-
Design, Development, and Calibration of an Electric Field Probe for Use on Sounding Rockets
… from each other which are free from bias voltages and bias currents to allow them to reach a floating potential within the plasma. The E-field can be derived from the measurement of the voltage difference between these 2 conductors. The voltage of each conductor can also be referenced to …
-
High Accuracy Real-time GPS Synchronized Frequency Measurement Device for Wide-area Power Grid Monitoring
… and transmits calculations of frequency, voltage magnitude and voltage angle to the remote servers via the Internet. Compared with its commercial counterpart Phasor Measurement Unit (PMU), FDR provides less expensive version for networked high-resolution real-time synchronized. The …
-
Model of electrically stimulated hernia mesh electrode for soft tissue healing
… materials to output small amounts of voltage by stimulating the piezoelectric material [6]. This output voltage has been shown to be achievable in soft tissues through transcutaneous medically safe 1MHz ultrasound waves stimulation of the piezoelectric material that mimic the effect of …
-
Bioelectrochemical systems powered by customizable microbial consortia
… by growing the organisms in BESs where a voltage difference between two electrodes provides additional thermodynamic impetus for the reactions by either accepting or donating electrons. Research to date has focused on the application of microbial fuel cells (MFCs) in which organisms …
-
Development of the vibrating capillary nebulizer sample introduction system for inductively coupled plasma mass spectrometry
… study of the signal response when turning voltage and frequency inputs, and evaluation of the long-term stability of nebulization. We found that with the VCN, we achieve detection limits in the ppt range and relative sensitivities as high as 1.98×104 cts/s / ng/mL. We show the range of …
-
Univerzální mikropočítačová jednotka
Diplomová práce obsahuje popis parametrů mikrokontroléru ATMEGA644P, dále popis rozdílů předchozích a novějších verzí ATMEGA644 a ATMEGA644PA. Je podrobně rozebrána vnitřní struktura mikrokontroléru, jeho paměťových prostorů a jeho periferií. Hlavním cílem práce je návrh mikropočítačové jednotky, …