Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 105 for “"voltage measurement"”.
-
High-voltage measurement techniques
… University of British Columbia acquired a high-voltage test set in 1979 for teaching and research purposes. To make this test set useful for experiments which undergraduate students can do themselves, various additions and modifications had to be made. This thesis describes these additions and …
-
High-voltage measurement using the quadrature method and permittivity-shielding
… and permittivityshielding for measuring high voltage using electric field sensors were developed. The quadrature method is a technique that determines the necessary number of sensors that make point-like measurements of the field and the best positioning and weighting of those sensors for any …
-
Voltage Measurement Using Slab-Coupled Optical Sensors with Polarization-Maintaining and Absorption-Reduction Fiber
… the use of the Panda-SCOS as means of voltage characterization across both the spark gap of an ignition coil circuit along with the spark gap of an automobile. This paper demonstrates the use of a Panda SCOS to measure the voltages and time delays across the spark gaps at different …
-
Design and Verification of a High Voltage, Capacitance Voltage Measurement System for Power MOSFETs
There is a need for a high voltage, capacitance voltage (HV, CV) measurement system for the measurement and characterization of silicon carbide (SiC) power MOSFETs. The following study discusses the circuit layout and automation software for a measurement system that can perform CV measurements for …
-
Digital one-cycle control technique with grid voltage measurement applied to three-phase power factor corrected rectifiers and active power filters
… the Digital One Cycle Control (DOCC) with grid voltage measurement to three-phase Power Corrected (PFC) Rectifier and Active Power Filter (APF). The use of grid voltage is explored in a generalized approach, by defining the influence of these measurements on harmonics, power factor and load …
-
Electrical properties of metal semiconductor contacts - metals on MoS2: a case study
… Schottky-Mott rules are discussed. The current-voltage measurement and capacitance-voltage measurement are analyzed considering the role of the work function. We mainly focus on metal semiconductor contacts on molybdenum disulfide (MoS2). The properties of bulk and monolayer molybdenum disulfide …
-
Multichannel digital voltmeter using the LM3S8962 evaluation board
… protects the evaluation board from over/under voltage damage, and biases the incoming voltages to provide usable input voltages for the LM3S8962 ADC inputs. The report begins with an explanation of the goals of the project, and research of what current products exist on the commercial market to …
-
Electrical characterization of thin film nanostructure templates
… with the system are analyzed with capacitance-voltage measurement techniques to provide insight into device operation. Ni is deposited into porous alumina templates to create Ni nanostructures.
-
Sphere-Gap Voltage Measurements
… of a 2 cm. sphere-gap as a standard of high-voltage measurement in the Electrical Engineering Department of the James Watt Laboratories of Glasgow University. Particular study has been made of the procedure necessary to obtain the greatest possible consistency in the results, and to determine …
-
Low-Power and High Precision Sensing Circuit for a Three-Channel Electrochemical Sensor
… that can simultaneously handle two current measurements, and one voltage measurement. This work provides a compact, low-power sensor architecture, with the intent for the serial readout to be replaced with a low-power radio frequency transmitter for continuous monitoring. The proposed …
-
Electrical and thermal analysis of gallium nitride HEMTs
… the location of HEMT structure that gate voltage measurement relates to. Secondly, we investigated the performance of single pulse and multiple pulses. Thirdly, we studied and compared the performance between the DC model and the Transient model (multiple pulses) with the same power. …
-
Enhancement Of The Spin Hall Effect In Platinum/Hafnium Alloy
… from the adiabatic (low frequency) harmonic Hall voltage measurement, the damping-like spin torque efficiency, which is the lower bound of the spin Hall angle, can be estimated. I demonstrated that the damping-like spin torque efficiency can be increased by over 50% by doping Hf impurity of 1% in …
-
The active complex electrode (ACE1) electrical impedance tomography system & anatomically inspired modeling of electrode-skin contact impedance
… complex electrode (ACE1) system for phasic voltage measurement. The ACE1 system was primarily designed for thoracic EIT applications, and its performance and limitations were tested through a variety of experiments. Additionally, the EIT forward problem was used to investigate electrode-skin …
-
Desenvolvimento Hardware in the loop para avaliação de reguladores de tensão na distribuição
… in the loop technique for the evaluation of a voltage regulator controller, the SEL 2431. Using a simulated distributed network with high penetration of solar generation in the OpenDSS program and sending and receiving analog/digital signals from this network to the controller through …
-
Characterization of In-plane Polarization Domains in 2D SnSe by Scanning Microwave Microscopy
… boundaries. This observation agrees with current-voltage measurement of devices fabricated on 2D SnSe and vertical Piezoresponse Force Microscopy (PFM) measurement result. This work, in short, we report and confirm the domain boundary is more conductive than the domain interior both theoretically …
-
Non-contact internal probing of high speed microelectronic circuits using electrostatic force microscopy
… non-invasiveness, high sensitivity, absolute voltage measurement and simplicity. An alternative internal probing technique based on the electro tatic force microscope (EFM) is investigated in this research. The localized electrostatic interaction between a small conducting probe and the test …
-
Development of a Low-cost Phasor Measurement Unit
… such as SCADA are being replaced by the Phasor Measurements Units due to their superior capabilities such as real-time and synchronize measurements. PMUs have many applications from gird protection to grid control, the down side however is that commercial PMUs have a high price tag staring at …
-
Integrated optical devices in lithium niobate
… a comparatorless A/D converter, and a high voltage sensor. An Impedance transformation equation for an exponential line is derived and used to obtain relations for the propagation constant of an optical waveguide with linearly graded index. The results are used to study the effect of a Ta₂O₅ …
-
Composite-semiconductor-based micro power source
… were fabricated and tested with current-voltage measurement at room temperature. A maximum output power of 687 nW was obtained from the micro power source using 1.24 GBq (33.61 mCi) of 35S. An open-circuit voltage of 410 mV and short-circuit current of 6.44 A were also observed. The …
Page 1 of 6