Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 261 for “"voltage measurements"”.

  1. Sphere-Gap Voltage Measurements

    … of a 2 cm. sphere-gap as a standard of high-voltage measurement in the Electrical Engineering Department of the James Watt Laboratories of Glasgow University. Particular study has been made of the procedure necessary to obtain the greatest possible consistency in the results, and to determine …

    glasgow

  2. High-Voltage Measurements Using Slab-Coupled Optical Sensors

    … sensors (SCOS) and their ability to measure high voltages. Although other high voltage measurement techniques exist, most of these techniques are electrical devices and are therefore more susceptible to stray ground currents and other electromagnetic interferences (EMI), which may cause signal …

    byu Repository record for High-Voltage Measurements Using Slab-Coupled Optical Sensors (opens in a new tab)

  3. Distribution system analysis using local-area voltage measurements

    … Measurement Units (PMUs), which measure the AC voltage and current traveling throughout the grid. However, questions related to both the economic investment and the actionable informational gains are the biggest impediments to the installation of more PMUs within the distribution system. A …

    uiuc Repository record for Distribution system analysis using local-area voltage measurements (opens in a new tab)

  4. Direct Voltage Measurements Using Bulk Acoustic Waves in LiNbO3

    Accurate (< 1%) direct measurement of high voltage pulse amplitudes above 10 kilovolts becomes challenging due to voltage breakdown limitations in materials, parasitic impedance effects that can distort the pulse shape, and pickup of extraneous signals resulting from electromagnetic interference …

    unm Repository record for Direct Voltage Measurements Using Bulk Acoustic Waves in LiNbO3 (opens in a new tab)

  5. Recovery of synaptic conductance and location using distal voltage measurements

    … location and synaptic conductance from distal voltage recordings. The ability to comprehend how synapses transmit information provides a better understanding of how the brain functions in terms of learning and memory. While other scientists take a more biological approach to solving this …

    rice Repository record for Recovery of synaptic conductance and location using distal voltage measurements (opens in a new tab)

  6. Investigation of dopant profiles from capacitance-voltage measurements on Schottky diodes

    … (C) of a Schottky diode as a function of voltage (V) is widely used to probe dopant profiles in semiconductors. However, the theory of the dopant profiling method is based on an approximation, and does not work well when the dopant concentration changes rapidly with distance. The region …

    ubc Repository record for Investigation of dopant profiles from capacitance-voltage measurements on Schottky diodes (opens in a new tab)

  7. Surface Characterization Of Thin Film Zno Capacitors By Capacitance-voltage Measurements

    … in the MOS/MIS devices. Hall-effect transport measurements and x-ray diffraction (XRD) spectroscopy are used to analyze the structure and electronic surface characteristics of the ZnO insulator. Capacitance-voltage (C-V) measurements are used to understand the effect of surface interface …

    ucf Repository record for Surface Characterization Of Thin Film Zno Capacitors By Capacitance-voltage Measurements (opens in a new tab)

  8. Development of Reference Tools for Medium Voltage Measurements in Smart Grids

    … design and the realization of a 30 kV reference voltage divider (VD) for smart grid monitoring, which will be mainly used in laboratories to characterize and calibrate the voltage transducers. The scale factor ratio error introduced by a normal voltage transducer (VT), according to technical …

    poli-torino Repository record for Development of Reference Tools for Medium Voltage Measurements in Smart Grids (opens in a new tab)

  9. Contactless Voltage Measurements and Their Applications for Silicon and Tandem Cells

    … provide spatially resolved data of the implied voltage (iV), a critical parameter for assessing single-junction devices, and individual analysis of subcells in tandem and multijunction devices. Extracting quantitative iV information from luminescence signals requires a calibration process and, …

    unsw Repository record for Contactless Voltage Measurements and Their Applications for Silicon and Tandem Cells (opens in a new tab)

  10. Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks

    … A Two-stage fault location algorithm using PMU voltage measurements proposed by Q. Jiang [14] is identified as the best option for adaption to operate with a linear state estimator. The algorithm is discussed in details and several case studies are made to evaluate its effectiveness. The …

    vt Repository record for Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks (opens in a new tab)

  11. STUDYING THE METAL/LAYERED SEMICONDUCTOR SCHOTTKY INTERFACE USING TEMPERATURE DEPENDENT CURRENT-VOLTAGE MEASUREMENTS AND BALLISTIC ELECTRON EMISSION MICROSCOPY

    … interfaces using temperature dependent current-voltage measurements (I-V-T) and ballistic electron emission microscopy (BEEM). I show that these interfaces are inhomogeneous and can be fit with at least two Gaussian distributions of Schottky barrier heights. Using BEEM, I experimentally verified …

    nus Repository record for STUDYING THE METAL/LAYERED SEMICONDUCTOR SCHOTTKY INTERFACE USING TEMPERATURE DEPENDENT CURRENT-VOLTAGE MEASUREMENTS AND BALLISTIC ELECTRON EMISSION MICROSCOPY (opens in a new tab)

  12. Vibrational excitation in a nitrogen plasma, generated by a dielectric-barrier discharge: exploring the possibilities of optical emission spectroscopy and current-voltage measurements

    … the available process variables, namely applied voltage amplitude, pressure and residence time. Also the specific energy input and the reduced electric field, two other relevant plasma parameters in a DBD reactor, are determined as a function of these process variables in order to find possible …

    eindhoven Repository record for Vibrational excitation in a nitrogen plasma, generated by a dielectric-barrier discharge: exploring the possibilities of optical emission spectroscopy and current-voltage measurements (opens in a new tab)

  13. Redox-Active Trivalent Metallosurfactants With Low Global Symmetry For Molecule-Based Electronics: Spectroscopic, Electrochemical, And Amphiphilic Properties Of New Molecular Materials For Current-Voltage Measurements In M|lb-Monolayer|m Devices

    LANKA D. W. WICKRAMASINGHE ARACHCHILAGE August 2014 Advisor: Professor Cláudio N. Verani Major: Chemistry (Inorganic) Degree: Doctor of Philosophy The silicon-based microelectronic industry has made remarkable technological advancements. Among these, new generation consumer electronics, …

    wayne-thes Repository record for Redox-Active Trivalent Metallosurfactants With Low Global Symmetry For Molecule-Based Electronics: Spectroscopic, Electrochemical, And Amphiphilic Properties Of New Molecular Materials For Current-Voltage Measurements In M|lb-Monolayer|m Devices (opens in a new tab)

  14. Advanced optoelectronic characterisation of solar cells

    … through the use of temperature dependent current-voltage and capacitance-voltage measurements. The injection barriers are shown to complicate the Mott-Schottky capacitance analysis which determines built-in bias and doping density. A model that incorporates depletion capacitance and a constant …

    oxford

  15. Measurements of Air Ion Concentrations and Electric Field Strengths for HVDC Applications

    High Voltage Direct Current (HVDC) enables transfer of electric power over long distances with high efficiency. In order to further increase the efficiency, the voltage levels are increasing. In turn, this means that for the design of both robust and cost effective electric insulation, the …

    chalmers Repository record for Measurements of Air Ion Concentrations and Electric Field Strengths for HVDC Applications (opens in a new tab)

  16. Non-contact internal probing of high speed microelectronic circuits using electrostatic force microscopy

    … non-invasiveness, high sensitivity, absolute voltage measurement and simplicity. An alternative internal probing technique based on the electro tatic force microscope (EFM) is investigated in this research. The localized electrostatic interaction between a small conducting probe and the test …

    manitoba Repository record for Non-contact internal probing of high speed microelectronic circuits using electrostatic force microscopy (opens in a new tab)

Page 1 of 14