Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 261 for “"voltage measurements"”.
-
Sphere-Gap Voltage Measurements
… of a 2 cm. sphere-gap as a standard of high-voltage measurement in the Electrical Engineering Department of the James Watt Laboratories of Glasgow University. Particular study has been made of the procedure necessary to obtain the greatest possible consistency in the results, and to determine …
-
High-Voltage Measurements Using Slab-Coupled Optical Sensors
… sensors (SCOS) and their ability to measure high voltages. Although other high voltage measurement techniques exist, most of these techniques are electrical devices and are therefore more susceptible to stray ground currents and other electromagnetic interferences (EMI), which may cause signal …
-
Distribution system analysis using local-area voltage measurements
… Measurement Units (PMUs), which measure the AC voltage and current traveling throughout the grid. However, questions related to both the economic investment and the actionable informational gains are the biggest impediments to the installation of more PMUs within the distribution system. A …
-
Direct Voltage Measurements Using Bulk Acoustic Waves in LiNbO3
Accurate (< 1%) direct measurement of high voltage pulse amplitudes above 10 kilovolts becomes challenging due to voltage breakdown limitations in materials, parasitic impedance effects that can distort the pulse shape, and pickup of extraneous signals resulting from electromagnetic interference …
-
Recovery of synaptic conductance and location using distal voltage measurements
… location and synaptic conductance from distal voltage recordings. The ability to comprehend how synapses transmit information provides a better understanding of how the brain functions in terms of learning and memory. While other scientists take a more biological approach to solving this …
-
Investigation of dopant profiles from capacitance-voltage measurements on Schottky diodes
… (C) of a Schottky diode as a function of voltage (V) is widely used to probe dopant profiles in semiconductors. However, the theory of the dopant profiling method is based on an approximation, and does not work well when the dopant concentration changes rapidly with distance. The region …
-
Surface Characterization Of Thin Film Zno Capacitors By Capacitance-voltage Measurements
… in the MOS/MIS devices. Hall-effect transport measurements and x-ray diffraction (XRD) spectroscopy are used to analyze the structure and electronic surface characteristics of the ZnO insulator. Capacitance-voltage (C-V) measurements are used to understand the effect of surface interface …
-
Development of Reference Tools for Medium Voltage Measurements in Smart Grids
… design and the realization of a 30 kV reference voltage divider (VD) for smart grid monitoring, which will be mainly used in laboratories to characterize and calibrate the voltage transducers. The scale factor ratio error introduced by a normal voltage transducer (VT), according to technical …
-
Contactless Voltage Measurements and Their Applications for Silicon and Tandem Cells
… provide spatially resolved data of the implied voltage (iV), a critical parameter for assessing single-junction devices, and individual analysis of subcells in tandem and multijunction devices. Extracting quantitative iV information from luminescence signals requires a calibration process and, …
-
Two-Stage Fault Location Detection Using PMU Voltage Measurements in Transmission Networks
… A Two-stage fault location algorithm using PMU voltage measurements proposed by Q. Jiang [14] is identified as the best option for adaption to operate with a linear state estimator. The algorithm is discussed in details and several case studies are made to evaluate its effectiveness. The …
-
Advanced Methodologies for High Voltage Measurements: From Composite and Combined Waveform to Uncertainty Reduction for Lightning Impulse
L'abstract è presente nell'allegato / the abstract is in the attachment
-
STUDYING THE METAL/LAYERED SEMICONDUCTOR SCHOTTKY INTERFACE USING TEMPERATURE DEPENDENT CURRENT-VOLTAGE MEASUREMENTS AND BALLISTIC ELECTRON EMISSION MICROSCOPY
… interfaces using temperature dependent current-voltage measurements (I-V-T) and ballistic electron emission microscopy (BEEM). I show that these interfaces are inhomogeneous and can be fit with at least two Gaussian distributions of Schottky barrier heights. Using BEEM, I experimentally verified …
-
Vibrational excitation in a nitrogen plasma, generated by a dielectric-barrier discharge: exploring the possibilities of optical emission spectroscopy and current-voltage measurements
… the available process variables, namely applied voltage amplitude, pressure and residence time. Also the specific energy input and the reduced electric field, two other relevant plasma parameters in a DBD reactor, are determined as a function of these process variables in order to find possible …
-
Redox-Active Trivalent Metallosurfactants With Low Global Symmetry For Molecule-Based Electronics: Spectroscopic, Electrochemical, And Amphiphilic Properties Of New Molecular Materials For Current-Voltage Measurements In M|lb-Monolayer|m Devices
LANKA D. W. WICKRAMASINGHE ARACHCHILAGE August 2014 Advisor: Professor Cláudio N. Verani Major: Chemistry (Inorganic) Degree: Doctor of Philosophy The silicon-based microelectronic industry has made remarkable technological advancements. Among these, new generation consumer electronics, …
-
Advanced optoelectronic characterisation of solar cells
… through the use of temperature dependent current-voltage and capacitance-voltage measurements. The injection barriers are shown to complicate the Mott-Schottky capacitance analysis which determines built-in bias and doping density. A model that incorporates depletion capacitance and a constant …
-
Measurements of Air Ion Concentrations and Electric Field Strengths for HVDC Applications
High Voltage Direct Current (HVDC) enables transfer of electric power over long distances with high efficiency. In order to further increase the efficiency, the voltage levels are increasing. In turn, this means that for the design of both robust and cost effective electric insulation, the …
-
Non-contact internal probing of high speed microelectronic circuits using electrostatic force microscopy
… non-invasiveness, high sensitivity, absolute voltage measurement and simplicity. An alternative internal probing technique based on the electro tatic force microscope (EFM) is investigated in this research. The localized electrostatic interaction between a small conducting probe and the test …