Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 134 for “"voltage signal"”

  1. Frequency to Voltage Signal Conditioner Circuit Design

    … report explains the design of a frequency to voltage converter circuit using a charge pump. In general, it may be considered a black box which accepts a 0 to 2 kHz frequency signal in, and outputs a 0 to 10 volt DC level. An additional feature of this circuit is the detection of digital …

    ucf Repository record for Frequency to Voltage Signal Conditioner Circuit Design (opens in a new tab)

  2. A LEAST ERROR SQUARES TECHNIQUE FOR ESTIMATING THE MAGNITUDE AND FREQUENCY OF A VOLTAGE SIGNAL

    … which estimates the system parameters such as voltage, current and frequency, using the- digitized samples obtained from the system. Developments of suitable algorithms to detect these parameters have been a major challenge to many researchers. This project is concerned with the development of …

    sask Repository record for A LEAST ERROR SQUARES TECHNIQUE FOR ESTIMATING THE MAGNITUDE AND FREQUENCY OF A VOLTAGE SIGNAL (opens in a new tab)

  3. Investigation of the Relationship Between Power Factor and Efficiency of Transcutaneous Power Transfer

    … power transfer, duty cycle of the source voltage signal, input impedance of the transmitter and primary power factor. A prototype of a transcutaneous power transfer system was built with a synchronously tuned series in: series out configuration at 2 MHz to demonstrate changes in the …

    marquette Repository record for Investigation of the Relationship Between Power Factor and Efficiency of Transcutaneous Power Transfer (opens in a new tab)

  4. Analysis and detection of tap changes on power systems

    … since tap changes play an important role in voltage regulation in power system and can reflect the variation of load. This thesis focuses on the analysis, modelling and detection of tap changes. <br><br>After an introduction on power systems and the OLTC transformer, an algorithm is proposed …

    oxford Repository record for Analysis and detection of tap changes on power systems (opens in a new tab)

  5. Investigation of signal shape effects on the gas film in spark-assisted chemical engraving

    … exists a literature gap regarding the impact of voltage signal shapes on this film. The thesis fills this void by investigating diverse voltage signal shapes designed to enhance the gas film stability. A robust methodology was established linking gas film properties to investigate the effects of …

    uoit Repository record for Investigation of signal shape effects on the gas film in spark-assisted chemical engraving (opens in a new tab)

  6. Operando plasmon resonance sensoring applied to sodium-ion batteries

    … was found that correlation between the optical signal and voltage signal was possible. The fast cycles in the cycling regime used, led to capacity fade, which can be seen to mainly affect the plateau region of the discharge voltage signal. This could be explained by the more sluggish diffusion …

    chalmers Repository record for Operando plasmon resonance sensoring applied to sodium-ion batteries (opens in a new tab)

  7. Thermally Driven Spin Transport in Ferromagnetic Metals

    … angle via the inverse spin hall effect (ISHE). A voltage signal is generated since the nonmagnetic material converts the spin current into a charge current in the direction orthogonal to both the spin current and spin polarization directions. Ferromagnetic (FM) metals can also convert the spin …

    denver Repository record for Thermally Driven Spin Transport in Ferromagnetic Metals (opens in a new tab)

  8. Fabrication of Piezoelectric Field Effect Transistors for Acoustic Signal Detection

    … gate, allowing a microwave-frequency voltage signal to be transmitted from a transducer to the transistor via acoustic conduction through the substrate. Using a single polycrystalline aluminum nitride film as the piezoelectric material, microwave-frequency piezoelectric transducers …

    ucf Repository record for Fabrication of Piezoelectric Field Effect Transistors for Acoustic Signal Detection (opens in a new tab)

  9. A Current Source for Electrical Impedance Tomography

    … waves.</p> <p>The DC offset from the DDS output voltage signal was removed and the voltage signal was amplified to ±10V (peak to peak) from ±325mV (peak to peak) in two stages. A fixed gain of 5 was implemented in the first stage and a variable gain (from 0 to 6) was implemented in the second …

    mcmaster Repository record for A Current Source for Electrical Impedance Tomography (opens in a new tab)

  10. An instrument for rapid determination of granularity in photographic film samples

    … allow the generation of a root-mean-square (rms) voltage signal proportional to rms Transmittance in the sample. A mathematical relation was then developed to calculate granularity. The scanner was calibrated and was proved capable of 10 percent accuracy with 95 percent confidence.

    rit Repository record for An instrument for rapid determination of granularity in photographic film samples (opens in a new tab)

  11. Pharmaceutical powder dispensing by ultrasonic vibration dosing system

    … i.e. orifice size, hopper angle, and working voltage signal, i.e. vibration duration, are the critical factors for the powder flow rate and dosage uniformity of the dispensing.<br/><br/>Additionally, the working voltage signal properties and mechanical vibration performance are investigated in …

    soton Repository record for Pharmaceutical powder dispensing by ultrasonic vibration dosing system (opens in a new tab)

  12. On using acousto-electric interaction effect for current mapping in denervated degenerated muscles: feasibility study, design and testing of instrumentation

    … conductivity change and the current produces a voltage signal, the acousto-electric interaction (AEI) signal, which can be recorded by surface electrodes. The signal has the same frequency as the ultrasound wave and if a focused ultrasound is used the spatial resolution of the signal can be of …

    reykjavik Repository record for On using acousto-electric interaction effect for current mapping in denervated degenerated muscles: feasibility study, design and testing of instrumentation (opens in a new tab)

  13. Multiphysics Gas Phase Pyrolysis Synthesis of Carbon Nanotube Yarn and Sheet

    … synthesis process to improve CNTYS properties. A voltage signal was measured inside the reactor, possibly for the first time. The voltage signal was induced by the heater coil and the electromagnetic coil current and creates a cold plasma. Simulation results predicted, for the first time, the …

    ohiolink Repository record for Multiphysics Gas Phase Pyrolysis Synthesis of Carbon Nanotube Yarn and Sheet (opens in a new tab)

  14. Development of an Optical Heart Rate Monitor using a Microchip PIC24-microcontroller based development board

    … pulse like a fingertip. The obtained heart beat signal is then passed through multiple amplification and filtering stages to obtain a clean and strong heart beat signal. Using this optical sensor module implemented on a printed circuit board (PCB) we can demonstrate several concepts related to …

    ohiolink Repository record for Development of an Optical Heart Rate Monitor using a Microchip PIC24-microcontroller based development board (opens in a new tab)

  15. Wireless System for Long-term and Real-time Subsurface CO2 Monitoring

    … design has beenoptimized to improve the received signal, and our results show significant improvementsin wireless power transfer efficiency. Using the optimized design, we can receive 1 to 10 %power transfer efficiency at 800 meters deep using only one toroidal transceiver with 1Acurrent as input. …

    houston Repository record for Wireless System for Long-term and Real-time Subsurface CO2 Monitoring (opens in a new tab)

  16. Electromechanical Characterization of the Static and Dynamic Response of Dielectric Elastomer Membranes

    … pressure input and (ii) a time-varying voltage input. For the time-varying pressure experiments, the prestretched membrane was inflated and deflated mechanically while a constant voltage was applied. The membrane was cycled between various predetermined inflation states, the largest of …

    vt Repository record for Electromechanical Characterization of the Static and Dynamic Response of Dielectric Elastomer Membranes (opens in a new tab)

  17. Applications of graphene in nanotechnology : 1D diffusion, current drag and nanoelectrodes

    … of Co adatoms on GNRs and on Au(111) using voltage pulses from the STM tip and we argue that motion is due to thermal excitations rather than the wind force. In chapter 3 we show that voltage signal is induced in a graphene strip when a droplet of ionic liquid is moved across its surface. …

    leiden Repository record for Applications of graphene in nanotechnology : 1D diffusion, current drag and nanoelectrodes (opens in a new tab)

  18. Classificação de distúrbios de energia elétrica baseada em sistemas imunológicos artificiais

    … each half cycle of the fundamental frequency voltage signal. The results demonstrate the algorithm's ability to classify disturbances such as sag, swell, outage and harmonics, with 100% efficiency rating. Another important feature of this approach is that it can be embedded, since the online …

    brazil-ufpb Repository record for Classificação de distúrbios de energia elétrica baseada em sistemas imunológicos artificiais (opens in a new tab)

  19. CONTROL OF FLOW AROUND AN AEROFOIL AT LOW REYNOLDS NUMBERS USING PERIODIC SURFACE MORPHING

    … of both the amplitude and frequency of the input voltage signal but the addition of aerodynamic forces does not cause significant changes in surface behaviour. The flow around the actuated aerofoil was compared with the unactuated flow. The latter exhibits large separation regions resulting from …

    nus Repository record for CONTROL OF FLOW AROUND AN AEROFOIL AT LOW REYNOLDS NUMBERS USING PERIODIC SURFACE MORPHING (opens in a new tab)

Page 1 of 7