The effect of weak electrical fields on troll success for spring (Oncorhynchus tschawytscha) and sockeye (Oncorhynchus nerka) salmon
… between the fishing gear and the vessel. Applied voltages of both polarities made up the treatment conditions. A preliminary field experiment investigated characteristic differences in troll success between port and starboard sets of gear. No significant differences were found and it was assumed …
-
Avaliação da resistência mecânica e da molhabilidade de fibras de aramida após tratamento com plasma de argônio
… with power of 50 and 100 Watts, and, for each voltage, tests were carried out with duration of 1, 3 and 5 minutes. The tests performed were tensile tests, tensiometry and scanning electron microscopy (SEM) By analyzing the results, it was observed that, for the 100 Watt treatment, the fiber …
-
Growth of ferroelectric thin films through metallo-organic decomposition
… on films grown on sapphire. Capacitance-voltage measurements yielded dielectric constants of about 28-32 for LiNbO$\sb3$ films on Si. The resistivity as measured from current-voltage tests was 10$\sp{12}$ to 10$\sp{13}$. The PZT films were crystalline and no particular grain orientation …
-
Application of Signal Processing Methods for Precision Impulse Voltage and Partial Discharge Measurements
… basis for reliable power grid. Different high-voltage tests are applied to grid components according to international standards after manufacturing to ensure the claimed performance. Accuracy of the used measuring systems is crucial when more cost-efficient and better-quality products are being …
-
EXPERIMENTAL TESTING OF SPIRAL AND WAFFLE PROTOTYPES OF 3D-PRINTED ARTIFICIAL MUSCLES
… survival rates. Capacitance and breakdown voltage tests showed that NaOH absorption was not responsible for sparking. Although no strong contractive force was measured, the Belgian Waffle displayed force behavior similar to biological muscles. Overall, the Belgian Waffle architecture …
-
Double-Side Cooled 3.3 kV, 100 A SiC MOSFET Phase-Leg Modules for Traction Applications
… validated through partial discharge inception voltage tests. Steps for fabricating the module are presented. Static electrical characterization of the fabricated module showed an average on-resistance of 31 mΩ and an average leakage current of 356 nA at VDS of 3 kV, which are similar to those …
-
Cyanate ester-nanoparticle composites as multifunctional structural capacitors
… of the cured composites. Breakdown voltage tests and dynamic mechanical analysis were employed to demonstrate that precise combinations of these constituents, under the proper processing conditions, can satisfy the needs presented by the aerospace industry and military forces.</p>
-
Precision electron flow measurements in a disk transmission line
… located at Sandia National Laboratories. Low voltage tests, V < 1 MV, were experimentally tested and provided a benchmark for the use of the PIC simulations to model marginally insulated electron flows. Experiments also allowed the development of a new diagnostic for measuring the electron …
-
Silicon oxynitride: A field emission suppression coating
… large, 3-D electrode structures used in high voltage applications, like those used by Thomas Jefferson National Accelerator Facility in their DC-field photoelectron gun. Currently time and labor-intensive hand-polishing procedures are used to minimize field emission from these structures. …
-
Design and Testing of a Biological Microelectromechanical System for the Injection of Thousands of Cells Simultaneously
… electrode and electrical connections to a voltage source. The suspension's motion is defined by two compliant orthoplanar springs that have been vertically and rotationally offset for added stability. The base of the suspension is designed to exactly fit in the bottom of a cell culture …
-
Space charge dynamics in polyethylene under periodical high voltage electric fields
… dynamics within polymeric insulation under high voltage direct current (HVDC) fields. Modern charge mapping techniques are adopted to obtain the necessary information about space charge within the insulation. However, the underlying physics of charge transport and the charge trapping …
-
Effects of Phase Composition and Microstructure on the Dielectric Strength of Thermally Sprayed Alumina Layer in Coating-Based Resistive Heating Systems
… diffraction (XRD) analysis. Dielectric breakdown voltage tests were conducted on selected heating systems and the performance of the alumina layer individually and within the heating system was examined. The advantages and disadvantages of using each of the thermal spraying processes and the …
-
Napěťové zkoušky za mokra
Cílem této práce je navrhnout sprchový systém pro rozšíření napěťových zkoušek o napěťové zkoušky za mokra. Na úvod je práce zaměřena na důležité požadavky, za kterých lze realizovat napěťové zkoušky za mokra. Tyto požadavky vychází převážně z českých i zahraničních norem. Další část práce je …
-
Time-of-flight characterisation of alternative propellants for porous Electrospray thrusters
… not been previously tested.<br/><br/>Current-voltage tests showed a large range of currents. EMI-FeCl4 emitted an especially large amount of current, with over 50 μA recorded for a single emitter. EMIBF4, EMI-SbF6, (EMI)2-Co(SCN)4 and C6(mim)2-Co(SCN)4 were found to emit similar currents, 10 …
-
Thermo-Mechanical Characterization and Interfacial Thermal Resistance Studies of Chemically Modified Carbon Nanotube Thermal Interface Material - Experimental and Mechanistic Approaches
… improvement of 40 to 50% with introduction of voltage gradient of 2 to 24 volts on LM-CNT TIM sample with 0.1 to 1 percent CNT volume fractions over non voltage LM-CNT TIM test samples. Key findings through this study show that voltage tests on LC- CNT TIM can cause increased CNT-CNT networks …
-
Development of a Monolithic Implantable Neural Interface from Cubic Silicon Carbide and Evaluation of Its MRI Compatibility
… a cathodic CSC of 15.2 ± 1.03 mC/cm^2. Current-voltage tests were conducted to characterize the p-n diode, n-p-n junction isolation, and related leakage currents. The turn-on voltage was determined to be on the order of ~1.4 V and the leakage current was less than 8 μArms. This all-SiC neural …
-
Development of a new test protocol for the permit Ion migration test
… the diffusion coefficient. Therefore, applied voltage tests (known as migration tests) have become quite common, in which the transport of chlorides ions through the test specimens is accelerated by applying a potential difference across them. The measurements during either the non-steady state …
-
Influence of Harmonic Distorted Voltages on the Dielectric Behaviour of Polymeric Insulation Materials
… may provoke harmonic distortion of the system voltage if they are not properly filtered or if resonance effects occur. The latter can be caused by the interplay of inductive and capacitive components as well as parasitic properties leading to additional capacitances. Single frequencies can then …