Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 53 for “"voltage unbalance"”.
-
Voltage Unbalance-Cognizant Optimization of Distribution Grids
… (DGs) into the distribution grid has exacerbated voltage unbalance issues leading to greater risks of reducing equipment lifetime, equipment damages, and increased ohmic losses. Most approaches to regulating voltage in distribution systems only focus on voltage magnitude and neglect phasor …
-
Impact of plug in electric vehicle battery charging on a distribution system
… battery chargers are mostly connected to the low-voltage grid for charging, hence their increased penetration coupled with uncoordinated charging could impact the distribution system in terms of voltage unbalance and transformer overloading. Although PEV battery charging is increasing, impact on …
-
Induction motor variable speed drive performance and impact on energy savings
… distribute power at a line-to-line voltage of 400+/-10%. Hence in theory, the user ends up with a voltage of 340 to 440. In urban areas 2% voltage unbalance is considered acceptable, while 3% voltage unbalance is considered acceptable for rural areas. The combined effects of under or …
-
High performance static converters for series compensation of industrial power systems
Deals specifically with voltage unbalance compensation, ac voltage regulation, and load power factor compensation in industrial power systems.
-
Impact of plug in electric vehicle battery charging on a distribution system based on real-time digital simulator
… on the distribution system in terms of maximum voltage deviation, voltage unbalance at various locations, transformers overloading, and introducing new peaks into the system. In this research, a 12.47 kV real distribution network has been modeled using real time digital simulator, using real …
-
Operation of induction machines in the presence of unbalanced supplies
… ratings when supplied with balanced sinusoidal voltages. However, the power system experiences unbalanced voltages, overvoltages, undervoltages, etc, which are seen at the motor terminals. The South African Electricity Supply Utility (Eskom) supplies the commercial and industrial systems with a …
-
Voltage Balancing Techniques for Flying Capacitors Used in Soft-Switching Multilevel Active Power Filters
This dissertation presents voltage stabilization techniques for flying capacitors used in soft-switching multilevel active power filters. The proposed active filter has proved to be a solution for power system harmonics produced by static high power converters. However, voltage unbalance of the …
-
Design and development of intelligent computational techniques for power quality data monitoring and management
… to handle non-linear loads faces the problem of voltage unbalance, sag, swell, momentary or temporary interruption and ultimately complete outage of EPDS. The PQ problems have motivated power system engineers to design and develop new methodologies and techniques to enhance EPDS performance. To …
-
Interphase power flow control and voltage regulation in distribution systems with high photovoltaic generation
… photovoltaic (PV) penetration, traditional voltage controls face increasing challenges in regulating voltages to within voltage tolerance limits. The voltage issues in the quasi-static steady-state include short-and long-duration RMS variations, voltage unbalance, and under/over voltage …
-
Market-Efficient and Robust Integration of DER in Unbalanced Distribution Systems
… addresses feasibility considerations in unbalanced three-phase networks by proposing a completion of voltage constraints. We develop a linearised proxy for voltage unbalance factor by applying first-order Taylor series expansion to the Line Voltage Unbalance Rate (LVUR) with linearised …
-
Interfacing dynamic phasor based system equivalents to an electromagnetic transient simulation
… phase locked loop are presented to eliminate the voltage unbalance effect in a phase locked loop. A comparison of the performance of the two filters is presented. The validation of the proposed interface is done using EMT simulation on real time digital simulator. Finally the numerical problems …
-
Automated detection and prediction of electrical disturbances in a power transmission system
… learning techniques are also used to predict voltage unbalance on the transmission system above a certain threshold, which yielded an accuracy of over 91%. This work will result in time savings for engineers as well as increased reliability of the transmission system by providing near …
-
The Effect of Unbalanced Voltages on an Induction Motor
… knowledge of the action of induction motors when voltages which are not balanced are impressed upon the terminals of the motor. It is realized and freely acknowledged that the results obtained in the laboratory are not strictly comparable to those which would be obtained under operating conditions …
-
Optimal management of voltage conditions in power distribution systems
… nature of these technologies can exacerbate the voltage unbalance level and pose additional operational stresses to the existing voltage regulation devices, such as power transformers. These conditions can introduce components failure, capacity waste, energy losses and restrict further …
-
Mätning och undersökning av elkvalitén i elnätet på reningsverket GRYYAB, Göteborg
… a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the …
-
Mätningar och undersökning av elkvaliteten i elnätet på reningsverket GRYAAB, i Göteborg
… a power quality survey was performed. The voltages and currents have continuously been sampled in the incoming 10 kV substation HSP01 from April-August 2008. Power quality measurements were also performed in Gryaabs other 10 kV substation HSP04 fed from HSP01 and at the terminals of the …
-
Algorithms for Induction Motor Efficiency Determination
… and RMS readings of no-load input power, input voltage, and input current. Experimental and field results of testing a total of 196 induction motors by using Method A are presented and the degree of accuracy is shown by comparing the estimated efficiencies to the measured values. Method B was …
-
Beiträge zur analytischen Berechnung und Reduktion der aus Netzspannungsunsymmetrien resultierenden Harmonischen in Systemen der Hochspannungs-Gleichstrom-Übertragung
An AC system’s voltage unbalance by a fundamental frequency negative sequence system is usually the main cause for the emission of non-characteristic harmonics by current source converters as used in conventional HVDC systems. This emission takes place on both sides of each 12-pulse converter. On …
-
Detailed investigation of negative sequence current compensation technique for stator shorted turn fault detection of induction motors.
… external effects (such as load change and supply voltage unbalances). This thesis addresses the limitations in shorted turn fault detection while considering real system disturbances and non-linearities using a dynamic motor model which is also verified by the experimental studies. The thesis …
-
The Formulation of a Novel Control Framework for Regulation of an Active Low Voltage Network
The low voltage (LV) Network has become more complex due to the addition of loads like Electric Vehicles (EVs) and generation from Renewable Energy Sources (RES). These additions will result in power quality issues arising from excess supply or load unbalance. As LV networks and power systems were …
Page 1 of 3