Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 152 for “"volume flow"”.

  1. Domain Decomposition for Multigrid, Finite Volume Flow Solvers

    Computing the flow fields about three-dimensional complex configurations accurately becomes a difficult task, if it is attempted to generate a single, body fitted grid with proper clustering. The domain decomposition methods, which divide the computational domain into less complex subdomains, are …

    odu Repository record for Domain Decomposition for Multigrid, Finite Volume Flow Solvers (opens in a new tab)

  2. Development of a microcomputer based flowmeter for liquid volume flow in partially full pipes

    A flowmeter was designed, developed and constructed to measure total volume flow in partially full pipes because a reliable, accurate flowmeter was not commercially available. The flowmeter system uses a pitot tube type sensor with a differential pressure transmitter and a bubbler tube with a …

    ut-knoxville Repository record for Development of a microcomputer based flowmeter for liquid volume flow in partially full pipes (opens in a new tab)

  3. Analysis and implementation of a high-order reconstruction algorithm for an unstructured finite volume flow solver

    … coarser than grids required by a second-order flow solver. The scheme was chosen based on two criteria. The first being that it is well documented in the literature for two-dimensional flow solvers. The second is that the scheme is extendable to the framework used in the Tenasi flow solver …

    utc Repository record for Analysis and implementation of a high-order reconstruction algorithm for an unstructured finite volume flow solver (opens in a new tab)

  4. Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Round Jet

    Particle image velocimetry (PIV) is an optical flow measurement technique that is used to measure volume flow rate at the exit of a turbulent, round nozzle. The objective of this thesis is to determine how to best make this measurement. The quality of the measurement is affected by a range of data …

    utahstate Repository record for Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Round Jet (opens in a new tab)

  5. Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Planar Jet

    Particle image velocimetry (PIV) is used to make volume-flow-rate measurements at the exit of a turbulent, planar nozzle. The objective of this report is to assess a range of data acquisition and processing parameters. Data is acquired for volume flow rates of Reynolds numbers between 10,000 and …

    utahstate Repository record for Best Practices for Volume Flow Rate Measurements Using PIV at the Exit of a Turbulent Planar Jet (opens in a new tab)

  6. Analog Computer Simulation of Glomerulus Filtration in the Renal System

    … is the object of this thesis to: 1) Simulate the volume flow equation (1) through the capillary vasculate of the kidney with the analog computer, and 2) Show quantitatively as well as qualitatively the effect of various parameter changes on the volume flow rate.

    ucf Repository record for Analog Computer Simulation of Glomerulus Filtration in the Renal System (opens in a new tab)

  7. Quantitative studies of flow in small blood vessels of the frog, Rana Pipiens, and of the hamster, Mesocricetus Auratus

    Quantitative relationships between blood flow velocity, vessel diameter, width of the peripheral plasma layer and induction of thrombus formation were studied in small blood vessels of the retrolingual membrane and intestinal mesentery of the frog, Rana Pipiens, and of the cheek pouch of the golden …

    bu Repository record for Quantitative studies of flow in small blood vessels of the frog, Rana Pipiens, and of the hamster, Mesocricetus Auratus (opens in a new tab) Embargoed until 2999-01-01

  8. MICROFLUIDIC DIODE PUMPING (PART I) AND RAPID DETECTION OF STEM CELL DIFFERENTIATION USING INDIUM TIN OXIDE OPTO-ELECTRIC SENSING (PART II)

    … by a surface mount diode in this research. The flow rates are controlled between 2.0 ~ 12.3 nL/s in a high salt concentration (>10 mM) aqueous solution. The A549 human lung cancer cells are cultured for a biocompatibility experiment under the ultra-low volumetric flow rate environment. (2). …

    mtu Repository record for MICROFLUIDIC DIODE PUMPING (PART I) AND RAPID DETECTION OF STEM CELL DIFFERENTIATION USING INDIUM TIN OXIDE OPTO-ELECTRIC SENSING (PART II) (opens in a new tab)

  9. Reducing Fuel Evaporation Using Floating Objects

    … surface was investigated. It is found that the volume flow rate of water vapor decreases for inlet speeds less than Re = 340 and increases for speeds greater than Re = 340 for horizontal inlet flow. Adding floating objects to the water surface affected the volume flow rate and volume …

    washington Repository record for Reducing Fuel Evaporation Using Floating Objects (opens in a new tab)

  10. Electric energy optimization for the pumps of a cooling and process water system at Södra Cell Värö

    … knowledge of the network, which resulted in a flow chart. By using the Excel-based computational programme Pumpanalys, the necessary pump head and users limiting in the network could be determined, giving information about the system head curve used for the suggestions for energy optimization. …

    chalmers Repository record for Electric energy optimization for the pumps of a cooling and process water system at Södra Cell Värö (opens in a new tab)

  11. An Analysis of Stock Densities and Harvest of the Cutthroat Trout of the Snake River, Teton County, Wyoming

    … rates are coincident with the fluctuating volume flows of the Snake River. Average lengths, condition factors, and catch per unit effort do not indicate significant changes in the fishery from past years. The population estimates and harvest data, coupled with volume flow information, …

    utahstate Repository record for An Analysis of Stock Densities and Harvest of the Cutthroat Trout of the Snake River, Teton County, Wyoming (opens in a new tab)

  12. Computational Fluid Dynamics Modeling of Counter-Current Flow in Channels Separated by a Membrane

    Counter current flow in channels separated by membrane were studied in several published studies. The present study aims to numerically and analytically simulate and physically describe the distribution of pressure, volume flow rate and velocity in counter current flow module. Numerical simulation …

    arkansas Repository record for Computational Fluid Dynamics Modeling of Counter-Current Flow in Channels Separated by a Membrane (opens in a new tab)

  13. Generalized Couette Flow of a Power-Law Fluid in an Annulus

    Generalized couette flow of a non-Newtonian power-law fluid in an annulus is analyzed. Cases ranging from pure shear flow to flow through an annulus with stationary walls are considered. Since the fluid does not exhibit linear characteristics, superposition of the solutions for pure shear (drag) …

    marquette Repository record for Generalized Couette Flow of a Power-Law Fluid in an Annulus (opens in a new tab)

  14. Investigation of field methods for evaluation of air-to-air heat pump performance

    … Method. However, the influence of the air volume flow measurement devices upon the testing unit itself, and the bulky equip-ment setup, make the SP Method infeasible for field testing during long time periods. The Climacheck Method is designed as a convenient way to carry out continuous …

    chalmers Repository record for Investigation of field methods for evaluation of air-to-air heat pump performance (opens in a new tab)

  15. A Non-Contact Volumetric Based Approach Using a Stereo Camera for Measuring Yield on Sugarcane Harvesters

    … yield on a sugarcane chopper harvester using a volumetric flow-based measurement of the harvested product on the elevator, and then converting to mass flow using a density that was found by calibration. Initial proof of concept testing on a stationary setup with a John Deere 3520 sugarcane …

    iastate Repository record for A Non-Contact Volumetric Based Approach Using a Stereo Camera for Measuring Yield on Sugarcane Harvesters (opens in a new tab)

  16. Droplet size measurements for liquid streams injected into a low-pressure chamber using a light transmission technique

    … vs. driving pressure was constructed. Mass and volume flow rates for the liquid injection system were calculated.

    nps Repository record for Droplet size measurements for liquid streams injected into a low-pressure chamber using a light transmission technique (opens in a new tab)

  17. Quantitative Cerebrovascular Magnetic Resonance Imaging

    … relevant numerical values associated with blood flow through the brain. Anatomy, pathology and basic angiography methods were reviewed. Several other MR imaging methods for obtaining cerebrovascular measurements are reviewed. Exploration of the lowest achievable variance with MR imaging was …

    calgary Repository record for Quantitative Cerebrovascular Magnetic Resonance Imaging (opens in a new tab)

  18. EXPERIMENTAL CHARACTERIZATION OF SPOOL VALVE FLOW NOISE

    … this research was to experimentally measure the flow noise produced by a spool valve and compare with measurements of orifice flow noise to reduce flow noise modelling complexity. The similarities and differences are compared over a range of volume flow rates, back pressures, and cross section …

    mtu Repository record for EXPERIMENTAL CHARACTERIZATION OF SPOOL VALVE FLOW NOISE (opens in a new tab)

Page 1 of 8