Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 78 for “"wall assemblies"”.
-
Mould Resistance of Full Scale Wood Frame Wall Assemblies
… the sheathing and framing within full scale wall assemblies. Secondary objectives were to investigate the difference in mould growth resistance between borate-treated and untreated wood products as well as provide information about mould growth under different temperature and humidity …
-
Experimental and Numerical Modeling of Heat Transfer in Wall Assemblies
… new building designs and materials, including wall and floor assemblies, provide an acceptable level of fire safety. A key fire safety requirement that is specified in building codes is the minimum fire resistance rating. A manufacturer of building materials (e.g., insulation or drywall) is …
-
Hygrothermal resiliency of wood-frame wall assemblies and climate change
… stucco, composite wood, and engineered wood clad wall assemblies in six Canadian climates. Across two chapters, the wall assemblies were analyzed under increasing wind-driven rain leakage and projected future climates. Two indices were developed to assess performance: a Robustness Index, based on …
-
Inwards vapor diffusion due to high temperature gradient in wall assemblies
… the experimental work performed on large-scale wall assembly specimens to document their hygrothermal performance under conditions leading to inwards moisture flow. A large-scale experimental facility was utilized for the purpose of this work which consisted of weighing apparatuses to monitor …
-
Measurement of Ventilation and Drying of Vinyl Siding and Brick Clad Wall Assemblies
… and heat flow through building enclosure assemblies is a critical component of overall building performance. This thesis shows that significant drying of moisture in wall assemblies is possible and that ventilation of cladding significantly increases the rate of drying in some assemblies …
-
Hygrothermal performance of different wood-frame wall assemblies wetted by simulated rain infiltration
… behind the exterior sheathing, i.e. the back wall. Once rainwater migrates into the stud space, it cannot easily evacuate and is thus likely to accumulate, leading to potential degradation of the wood studs and exterior sheathing, depending on the temperature conditions. Therefore, studying …
-
Impact of added insulation on the hygrothermal performance of leaky exterior wall assemblies
… the effect of adding insulation to leak exterior wall assemblies and to monitor air leakage paths within them. The procedure involves the construction of a full-scale test hut exposed consecutively to climatic conditions representing winter and late spring, inside the environmental chamber. Two …
-
Moisture Response of Wall Assemblies of Cross-Laminated Timber Construction in Cold Canadian Climates
… the moisture durability of CLT panels in wall assemblies and address concerns related to built-in construction moisture. The approach used to address the problem was to first determine select moisture properties of CLT panels through experimental approaches, and then use the results to …
-
Assessing Moisture Resilience of Wall Assemblies to Wind-Driven Rain Loads Arising from Climate Change
… façades can induce detrimental effects to wall assembly components and can adversely influence their long-term performance. Wind-driven rain as a climatic phenomenon will inevitably be affected by the evident changing climate in the near future. Wall assemblies subjected to wind-driven rain …
-
Recommended Modified zone Method Correction Factor for Determining R-values of Cold-Formed Steel Wall Assemblies
… in conductivity, such as cold-formed steel (CFS) walls. Because there is currently no standard U-Factor calculation method for CFS walls, designers and code officials alike tend to resort to the zone method. However, the zone method is restricted to larger span assemblies because the zone factor …
-
Moisture Risk Assessment in Cross-Laminated Timber Wall Assemblies under Future Climates through Validated 2D Hygrothermal Modeling
… issues in Cross-Laminated Timber (CLT) wall assemblies, particularly at junctions and interfaces where drying potential is limited. With growing focus on climate-adaptive design, hygrothermal simulations are widely used to assess long-term performance under varying environmental loads. …
-
Existing Buildings against Climate Zone Shifts: Analysis of the resilience of existing buildings in changing climate zones
… performance and durability of existing building wall assemblies designed under previous International Energy Conservation Code (IECC) requirements. As global climate change continues to alter temperature, humidity, and extreme weather patterns, building codes and climate classifications are …
-
Behavior of Residential Safe Room Walls Impacted by Windborne Debris
… missile is fired at high speeds at safe room assemblies. Prescriptive designs may be utilized for residential safe rooms; however, these designs can be costly and difficult to construct. The purpose of this research is to 1) Test safe room wall assemblies constructed with conventional steel …
-
Composite concrete masonry systems for residential architecture
… advantage of composite concrete masonry cavity wall construction. Concrete has a low thermal resistance which has limited its use in energy efficient structures. By placing a core of insulation between two concrete wythes, the thermal resistance of the wall section can be greatly improved. The …
-
Identify an Ideal Residential Wall Assembly for Las Vegas Climate Considering Construction Cost, Energy Performance and Embodied Energy
… study aims to identify an energy efficient wall assembly that can be use in the U.S. desert southwest, that is suitable for the environment. With the use of research and simulations, using BEopt version 2.4.0.1, this investigation compares and evaluates different exterior wall assemblies to …
-
The Development of a Highly Insulated, Thin Wall Assembly for Canadian Residential Construction
… stringent on requirements for highly insulated wall assemblies to reduce building heating loads, thereby reducing emissions. However, traditional means of insulating a wall significantly increase its thickness and in scenarios where the building's footprint is constrained this causes a decrease …
-
On the Fire Performance of Exterior Wall Materials and Assemblies
… to the overall performance of the exterior wall in meeting energy efficiency and hygrothermal requirements. Nowadays, multi-layered exterior envelopes are taking centre stage in construction, gradually replacing conventional monolithic concrete and masonry façades. Predicting fire …
-
The Effects of Moisture and Addition of Rigid Insulation to Exterior Walls on Building Envelope Performance
… with different insulation materials inside the wall cavities. One had fiberglass batt and other with dense pack cellulose. The test program was completed at the Alternative Village at the University of Manitoba. Combinations of external rigid insulation and vapour barrier systems were compared …
Page 1 of 4