Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"wall base"”

  1. Simulação Numérica da Humidade Ascensional em Edifícios Históricos

    … appears when the constituent materials of the walls exhibit high capillarity and these walls are in contact with water or wet soil. In this work different treatment techniques were analyzed, particularly the technique treatment named "wall base ventilation". With the help of an automatic …

    porto Repository record for Simulação Numérica da Humidade Ascensional em Edifícios Históricos (opens in a new tab)

  2. Dimensionamento de Sistemas de Ventilação da Base das Paredes para Tratamento da Humidade Ascensional

    … and ancient buildings, essentialy, of this thick walls with heterogeneous composition. In the Building Physics Laboratory - "Laboratório de Física das Construções" - LFC of Oporto University Engineering School - "Faculdade de Engenharia da Universidade do Porto - FEUP", has been developed an …

    porto Repository record for Dimensionamento de Sistemas de Ventilação da Base das Paredes para Tratamento da Humidade Ascensional (opens in a new tab)

  3. A finite element modeling study on the seismic response ofcantilever retaining walls

    … performed in order to investigate the effects of base excitation characteristics (peak acceleration amplitude and frequency of the excitation), soil strength and wall flexibility on the dynamic response of cantilever earth-retaining walls. In this study, Plaxis v8.2 dynamic finite element code was …

    metu Repository record for A finite element modeling study on the seismic response ofcantilever retaining walls (opens in a new tab)

  4. Seismic response of displacing and non-displacing retaining systems: new insights

    This Thesis aims to clarify the Soil Retaining Wall Interaction (Chapter 1) by numerically and analytically examining the seismic response of: (a) Four different types of retaining walls, initially introduced in the centrifuge experiments of Sitar and co-workers; and (b) Three simple gravity wall …

    greece Repository record for Seismic response of displacing and non-displacing retaining systems: new insights (opens in a new tab)

  5. Seismic Response of Buildings that Utilise Unbonded Post-Tensioned Concrete Walls

    Unbonded post-tensioned precast concrete walls are a low-damage seismic resisting system that resist lateral loads by rocking at the wall base. This thesis addresses the uncertainty that wall-to-floor interaction can have on the seismic response and performance of buildings that use such wall …

    auckland-ms Repository record for Seismic Response of Buildings that Utilise Unbonded Post-Tensioned Concrete Walls (opens in a new tab)

  6. Evaluation of behavior and the radial shear strength of a reinforced concrete containment structure

    … and to estimate the internal forces at the wall-basemat connection. Analytical models were developed for radial-expansion response and for the wall and basemat interaction. A possible mode of structural failure of containments subjected to high pressures is by radial-shear failure at the …

    uiuc Repository record for Evaluation of behavior and the radial shear strength of a reinforced concrete containment structure (opens in a new tab)

  7. Evaluation of lower damage concepts for enhanced reparability of reinforced concrete walls

    … the unsatisfactory performance of concrete walls and improved current design standards to result in a more ductile response. However, despite meeting the current performance objectives of the design standards, reinforced concrete walls may still require extensive or costly post-earthquake …

    unr Repository record for Evaluation of lower damage concepts for enhanced reparability of reinforced concrete walls (opens in a new tab)

  8. Behavior of Precast Concrete and Masonry Wall Systems with Jointed Connections Subjected to Lateral Loads

    … the use of precast concrete and masonry walls with jointed connections at the wall-to-foundation interface. These walls resist the seismic lateral loads by rocking motion, which minimizes damage and re-centers the full structure effectively, providing seismic resilience. Nevertheless, …

    umn Repository record for Behavior of Precast Concrete and Masonry Wall Systems with Jointed Connections Subjected to Lateral Loads (opens in a new tab)

  9. A study of model retaining walls supported by multi-plate anchors.

    … the behaviour of a 0.6 m high rigid retaining wall in a normally consolidated sand and supported by up to four rows of' anchors, was studied. Different design methods were employed to examine the overall stability of the wall-anchors-soil system. These were investigated experimentally in a …

    whiterose Repository record for A study of model retaining walls supported by multi-plate anchors. (opens in a new tab)

  10. Seismic performance of RC structural squat walls with limited transverse reinforcement

    … shear in reinforced concrete (RC) structural walls with low aspect ratios. Significant progress has been achieved in the understanding of global and local responses of such RC structural walls. These squat walls are usually detailed according to current provisions and reinforced against the …

    nanyang Repository record for Seismic performance of RC structural squat walls with limited transverse reinforcement (opens in a new tab)

  11. Εργαστηριακή και υπολογιστική μελέτη της σεισμικής συμπεριφοράς τοιχωμάτων από οπλισμένο σκυρόδεμα επισκευασμένων και ενισχυμένων με ινοπλισμένα πολυμερή

    … reinforces concrete(R?C) structural walls that were tested to failure during a first series of tests, and were subsequently repaired, before being strengthened with FRP sheets. For this purpose an experimental programme was designed that included the repair and strengthening of eleven …

    greece Repository record for Εργαστηριακή και υπολογιστική μελέτη της σεισμικής συμπεριφοράς τοιχωμάτων από οπλισμένο σκυρόδεμα επισκευασμένων και ενισχυμένων με ινοπλισμένα πολυμερή (opens in a new tab)

  12. Seismic Design of Lightly Reinforced Concrete Walls in Tall Buildings

    … highlighted that reinforced concrete (RC) walls designed with a low amount of vertical reinforcement are susceptible to sudden failure caused by strain concentration and reinforcement fracture at discrete cracks. Subsequent research resulted in amendment to the minimum vertical …

    auckland-ms Repository record for Seismic Design of Lightly Reinforced Concrete Walls in Tall Buildings (opens in a new tab)

  13. Inelastic Dynamic Behavior And Design Of Hybrid Coupled Wall Systems

    … and energy dissipation capacity. Hybrid coupled wall systems, in which steel beams are used to couple two or more reinforced concrete shear walls in series, can be designed to have these attributes and therefore have the potential to deliver good performance under severe seismic loading. This …

    ucf Repository record for Inelastic Dynamic Behavior And Design Of Hybrid Coupled Wall Systems (opens in a new tab)

  14. The effect of structural interactions due to floors, parapets and lintels on the lateral response of segmented cross laminated timber (CLT) shear walls

    … exclusively from CLT panels, which serve as both walls and floors, with CLT walls acting as both gravity and lateral load resisting systems. There are two main construction techniques for CLT buildings: platform-type and balloon-type methods. Platform-type construction involves building each floor …

    ubc Repository record for The effect of structural interactions due to floors, parapets and lintels on the lateral response of segmented cross laminated timber (CLT) shear walls (opens in a new tab)

  15. Seismic response of cantilever shear wall buildings

    … to estimate the demands on cantilever shear wall buildings due to the design level earthquakes. A hysteretic bending moment - curvature relationship was developed and implemented into computer program OpenSees. The study included 15 different shear wall buildings that ranged in height from 10 …

    ubc Repository record for Seismic response of cantilever shear wall buildings (opens in a new tab)

  16. Seismic performance of a post-tensioned concrete masonry wall system

    … of a post-tensioned concrete masonry (PCM) wall system designed using generic materials. PCM walls derive their lateral strength and self-centering behaviour from unbonded post-tensioning. During in-plane loading, a horizontal crack forms at the wall base, which minimises masonry tensile …

    auckland-ms Repository record for Seismic performance of a post-tensioned concrete masonry wall system (opens in a new tab)

  17. Seismic Retrofit of Reinforced Concrete Shear Walls Using Selective Weakening and Self-Centering

    … non-ductile slender reinforced concrete shear walls using weakening and self-centering. This retrofit solution aims at minimizing damage and residual drift to ensure resiliency. Past earthquakes have shown that RC buildings with shear walls designed according to older code provisions (e.g. ACI …

    buffalo Repository record for Seismic Retrofit of Reinforced Concrete Shear Walls Using Selective Weakening and Self-Centering (opens in a new tab)

  18. Influence of Foundation Rigidity on the Out-Of-Plane Flexural Response of Slender Masonry Walls

    Masonry walls with effective height-to-thickness (kh/t) ratios over 30 are commonly found in single-storey buildings such as school gymnasiums, warehouses, and industrial facilities. Stringent design requirements apply for walls with kh/t > 30 in North American Standards (CSA S304-14, TMS 402-16) …

    alberta Repository record for Influence of Foundation Rigidity on the Out-Of-Plane Flexural Response of Slender Masonry Walls (opens in a new tab)

  19. Seismic Design of Lightly Reinforced Concrete Walls

    … several lightly reinforced concrete (RC) walls in multi-storey buildings formed only a limited number of cracks at the wall base with fracture of vertical reinforcement observed. Initial investigation highlighted that the vertical reinforcement content was a key parameter that influenced …

    auckland-ms Repository record for Seismic Design of Lightly Reinforced Concrete Walls (opens in a new tab)

  20. Impact of cross section, web reinforcement and load history on the seismic performance of slender concrete walls

    … seismic regions employ reinforced concrete shear walls as part of the lateral force resisting system and these walls often have non-planar cross-sectional geometries. To date, the majority of experimental tests on slender concrete walls have been conducted on planar walls which have been subject …

    uiuc Repository record for Impact of cross section, web reinforcement and load history on the seismic performance of slender concrete walls (opens in a new tab)

Page 1 of 2