  1. Investigation of Cavity Wall Ties

    … and tensile) of the most commonly used cavity wall ties. Z, Truss, Ladder and Corrugated metal ties were tested in the Applied Dynamics Laboratory at McMaster University.</p> <p> A total of 110 specimens were constructed and tested. Fifty-five specimens were tested in compression, another 55 …

    mcmaster Repository record for Investigation of Cavity Wall Ties (opens in a new tab)

  2. Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads

    … between brick veneers and concrete masonry shear walls. The amount of load transferred through wall ties depends on factors such as tie spacing, tie stiffness, reinforcement, etc. Results indicate that some degrees of composite action exist; around 12 % to 37 % of the applied shear load is …

    ohiolink Repository record for Analysis of Brick Veneer on Concrete Masonry Wall Subjected to In-plane Loads (opens in a new tab)

  3. Development of prestressed clay brick masonry walls

    Prestressed masonry walls offer various advantages over the current system of veneer construction which has been shown to have several problems. The cracking of masonry walls at service loads, and corrosion of wall ties due to water penetration can be effectively eliminated by the simple technique …

    nebraska Repository record for Development of prestressed clay brick masonry walls (opens in a new tab)

  4. Seismic behaviour of masonry veneer walls

    It is recognized that masonry veneer walls, commonly used in commercial, industrial and residential buildings can be vulnerable to earthquakes and most of the reported cases of failures are due to poor materials, design and inadequate construction practices. This inadequate behaviour has promoted …

    minho-thes Repository record for Seismic behaviour of masonry veneer walls (opens in a new tab)

  5. Factors Affecting the Performance of Brick Veneer Construction

    … or had no effect on the performance of the wall system. First, quasi-static out-of-plane tests were performed on specimens with wood frame backing. These first tests compared the performance of the wall system with and without the joint reinforcement, as well as the ductility of the two …