Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 41 for “"water Cherenkov detector"”
-
The CHIPS Prototype Water Cherenkov Detector
The CHIPS (CHerenkov detectors In mine PitS) detector was a large-scale water Cherenkov (WC) long baseline neutrino detector located in northern Minnesota. It was located 7 mrad off-axis, 712 km downstream from the NuMI neutrino source at Fermi National Accelerator Laboratory and with a fiducial …
-
Determination of the Muon Lifetime With a Water Cherenkov Detector
… the charge-averaged muon lifetime with a water Cherenkov detector, using a high-speed digitizer to read out a photomultiplier tube, has been developed for an advanced student laboratory. An approximately 0.40 m3 cylindrical stainless-steel container has been constructed at the University …
-
Design, simulation, and prototyping of wavelength-shifting plate light collector for a large water Cherenkov detector
… collector has been investigated for a proposed water Cherenkov detector for the Long-Baseline Neutrino Experiment. Experimental prototypes were fabricated from four different wavelength-shifting plastics and tested under uniform illumination as well as with a point source scanner. These …
-
Dark Matter annihilation cross-section limits of dwarf spheroidal galaxies with the high altitude water Cherenkov (HAWC) gamma-ray observatory and on the design of a water Cherenkov detector prototype
… search for Dark Matter using the High Altitude Water Cherenkov (HAWC) gamma-ray observatory. There is significant evidence for dark matter within the known Universe, and we can set constraints on the dark matter annihilation cross-section using dark matter rich sources. Dwarf spheroidal galaxies …
-
Time Calibration of IWCD: A new water Cherenkov near detector for Hyper-Kamkiokande
… calibration of a new Intermediate Distance Water Cherenkov Detector (IWCD) for the long-baseline neutrino oscillation experiment from Tokai to Hyper-Kamiokande. The timing calibration method studied for water Cherenkov detectors uses a flash of light in the detector and can be applied in any …
-
Development of scintillator-based components for the photosensor system for the Intermediate Water Cherenkov Detector of the Hyper-K experiment and for the time of flight system of the Water Cherenkov Test Experiment
… question in the Universe. With a new far detector and upgraded components of the successful Tokai-to- Kamioka (T2K) experiment, the long-baseline aspect of the Hyper-Kamiokande (Hyper-K) experiment will utilize an upgraded neutrino beam from the Japan Proton Accelerator Research Complex …
-
Reactor Antineutrinos In The Sno+ Water Phase And Detector R&d For Large-Scale Neutrino Detectors
… reactor antineutrino interactions in the SNO+ water-filled detector using a 190.3 day dataset. Reactor neutrinos have never before been detected in a water Cherenkov detector, primarily due to the difficulty in detecting the low energy signal from neutron captures on free protons. However, …
-
An analysis of the oscillation of atmospheric neutrinos
… in Super-Kamiokande, a large underground water Cherenkov detector in Japan. The observed atmospheric neutrino events are reconstructed and selected using a newly developed maximum likelihood event reconstruction algorithm, and a Markov chain Monte Carlo technique is employed to present the …
-
Reactor neutrinos in a gadolinium-loaded Super-Kamiokande
In July of 2020, Super-Kamiokande (SK), a 50 kt water Cherenkov detector, entered its new phase: SK-Gd [1]. In this phase, the detector’s once-ultrapure water was doped with 0.02% gadolinium sulphate octahydrate by mass, increased to 0.06% in July 2022. This provides far greater sensitivity to …
-
EFFECTS OF MASS AND DISTANCE UNCERTAINTIES ON CALCULATIONS OF FLUX FROM GIANT MOLECULAR CLOUDS
… flux can be compared to actual flux data from a detector. Uncertainties from measuring the mass of and distance to the clouds are taken into account for this prediction. This report also discusses the HAWC water Cherenkov detector and why it is a good resource for this study. HAWC significance …
-
Calibration Techniques for Enhanced Neutrino Detection in Hyper-Kamiokande and WCTE Experiments
… is a next-generation long-baseline neutrino detector that aims to investigate crucial questions in experimental particle physics, which includes the search for CP violation in the lepton sector, the neutrino mass hierarchy, and the octant problem. To support this, accurate calibration of …
-
Very-High-Energy and Ultra-High-Energy Gamma-ray emission from the Galactic Centre
… telescopes, an array of imaging atmospheric Cherenkov telescopes. A novel background rejection technique, ABRIR, is developed and implemented within the H.E.S.S. analysis software. ABRIR uses time-based image cleaning and muon tagging to improve signal extraction from high-energy gamma-ray …
-
A search for time dependence in astrophysical neutrino sources with the Sudbury Neutrino Observatory
… an upper limit on the senstitivity of our detector for such an observation. I include discussions of backgrounds to such a search that are specific to a heavy-water Cherenkov detector such as SNO.
-
Measurement of νμ induced charged current inclusive cross section on water using the near detector of the T2K experiment
… towards the 50 kiloton Super-Kamiokande (SK) water Cherenkov detector located 295 km away. Measurements from a Near Detector that is 280m downstream of the neutrino beam target are used to constrain uncertainties in the beam flux prediction and neutrino interaction rates. We present a …
-
Boosted dark matter and atmospheric neutrino Earth matter effects at Super-Kamiokande
… with data from Super-Kamiokande, a 50 kT water Cherenkov detector located 1,000 meters below Mt. Ikenoyama in Gifu, Japan, which has been operating since 1996. The first study searches for Earth matter effects in atmospheric neutrino oscillations. Earth matter effects have never before …
-
The search for CP violation in neutrino oscillations at T2K
… production point at Super-Kamiokande, a 50 kt water Cherenkov detector capable of differ- entiating between muon neutrino and electron neutrino events. Two beam configurations are possible at T2K, each used to create neutrino beams composed of predominantly neutrinos or anti-neutrinos. …
-
Astrophysics and Physics of Neutrino Detection
… of which the signals can be picked up by a water Cherenkov detector on the Earth. From an astrophysical point of view, the signals reveal the dynamics of core-collapse supernova explosion and the subsequent cooling of a proto-neutron star (PNS). In this regard, we compare the neutrino …
-
A Search for Short Duration Very High Energy Emission from Gamma-Ray Bursts
Milagro is a water-Cherenkov detector capable of observing air showers produced by gamma rays with primary energies of approximately 100 GeV and higher. The wide field of view (~ 2 sr) and high duty cycle (>90%) of Milagro make it ideal for searching for transient emission from gamma-ray bursts …
-
Measurement of Tau Neutrino Appearance and Charged-current Tau Neutrino Cross Section with Atmospheric Neutrinos in Super-Kamiokande
<p>Super-Kamiokande is a 50 kiloton water-Cherenkov detector in Japan, which has been collecting atmospheric neutrino data for more than 20 years. Tau neutrino appearance is expected in atmospheric neutrinos due to neutrino oscillations. The wide span of neutrino energies and neutrino path lengths …
-
Next Discoveries in Neutrino Mixing: Electron Neutrino Appearance
… $/$\bar{\nu}_{e}$ appearance experiment, a near detector (ND) is used to constrain the neutrino flux and measure the backgrounds to the signal. Backgrounds to the $ \nu_{e} $ appearance comes from Neutral Current Muon Neutrino Interactions ($\nu_{\mu}$-NC), Charged Current Muon Neutrino …
Page 1 of 3