Association of lingual myoarchitecture with local mechanics during swallowing determined by magnetic resonance imaging
… to first configure and then transport the bolus from the oral cavity to the pharynx during swallowing. In order to observe the synergistic interactions of the eight different muscles in the tongue, MRI techniques were used to determine the three-dimensional fiber architecture, measure the …
-
The design and development of intracavitary ultrasound arrays for hyperthermia.
… or local heating rates. A temperature regulated water bolus provided acoustic coupling and additional control over the depth of the maximum temperature from the cavity wall. These applicators were tested in vivo and in vitro and were able to induce controlled transrectal heating at depths of 2-3 …
-
Modeling the SIGMA-Eye Applicator for Hyperthermia via Multiple Infinitesimal Dipoles
… In addition, the frequency dependence and water-bolus permittivity and conductivity dependence of the block-based modified IDM was explored, and it was found that this approach is applicable for a narrow-band frequency, and is adaptable to the uncertainty of the water-bolus permittivity and …
-
Improved strategies for the evaluation of cerebral blood flow and cerebrovascular reserve capacity using dynamic positron emission tomography
… emission tomography (PET) with 15O-labelled water is commonly achieved using the one-compartment model of Kety. Unlike this model, a recently developed two-compartment CBF model accounts for nonextracted intravascular radioactivity and therefore provides with perfusion (CBF) as well as …
-
Efekt velikosti vodního bolu na vyzařování metamateriálové antény
… změny ve směrech x a y měly omezený dopad, pokud bolus pokrýval aktivní plochu antény. Vlnovodná anténa dosáhla nejvyšších hodnot EFS a EPD, ale za cenu vysoké hmotnosti (13,34kg) a tloušťky (14cm). MTM antény umožnily efektivní přenos energie s výrazně nižší hmotností (3,14kg a 4,25kg). …
-
Přesnost teplotních predikcí v povrchové hypertermické léčbě
Přesnost teplotních predikcí v povrchové hypertermické léčbě: Cíle: Cílem projektu bylo vyhodnotit přesnost teplotních predikcí pro povrchovou hypertermii v závislosti na změnách teplotních parametrů, a to na prokrvení (perfuzi) a tepelné vodivosti tkáně při hypertermickém ohřevu. Metody: Pro deset …