Showing 1 to 16 of 16 for “"wavefront analysis"”.
-
Diffraction wavefront analysis of computer-generated holograms
… holograms (CGHs) use diffraction to create wavefronts of light with desired amplitude and phase variations. The amplitude control is well known. But the sensitivity of phase, which is most important for some applications, such as interferometry, is less known. This dissertation studies phase …
-
Wavefront Analysis and Calibration for Computer Generated Holograms
… light, CGHs are capable of generating reference wavefronts of any desired shape, which allows using of interferometers for measuring complex aspheric surfaces. Fabrication errors in CGHs, however, cause phase errors in the diffracted wavefront, which directly affects the accuracy and validity of …
-
Wavefront Analysis and Calibration for Computer Generated Holograms
… light, CGHs are capable of generating reference wavefronts of any desired shape, which allows using of interferometers for measuring complex aspheric surfaces. Fabrication errors in CGHs, however, cause phase errors in the diffracted wavefront, which directly affects the accuracy and validity of …
-
Μελέτη της ασφάλειας και αποτελεσματικότητας ενός προσαρμοστικού ενδοφακού νέας γενιάς
… of subjective (visual acuity) and objective (wavefront analysis) measurements.Methods In this prospective case series, twenty – five patients (fifty eyes) with mean age: 65, 3 ± 8, 4 years (range from 53to 83 years) were included. All patients underwent routine cataract surgery and WIOL – CF …
-
Measurement of Amplitude and Phase Pupil Variation for EUV Lithography Systems
… lithography systems with estimates for the wavefront tolerance below 500 pm RMS. These systems use radiation at a wavelength of 13.5 nm. No materials sufficiently refract this radiation, so reflective lens designs must be used. The mirrors are constructed as Bragg reflectors and much of the …
-
Αντικειμενική αξιολόγηση της δυσφορίας θάμβους σε νοσήματα του πρόσθιου ημιμορίου του οφθαλμού
… de Boer scale. Corneal topography-based wavefront analysis, pupil size, and angle kappa were calculated to identify possible significant correlations. Results: Mean values of discomfort glare for the patients’ group were 1.66 (SD 1.5) at 500 lx, 2.7 (SD 1.68) at 3000 lx, and 3.16 (SD …
-
Phase diversity wavefront sensing for control of space based adaptive optics systems
Phase Diversity Wavefront Sensing (PD WFS) is a wavefront reconstruction technique used in adaptive optics, which takes advantage of the curvature conjugating analog physical properties of a deformable mirror (MMDM or Bi-morph) such that the computational intensity required for correcting an …
-
Measuring aberrations in lithographic projection systems with phase wheel targets
… of nanolithographic image fidelity is optical wavefront aberration. Aerial image sensitivity to aberrations is currently much greater than in earlier lithographic technologies, a consequence of increased resolution requirements. Optical wavefront tolerances are dictated by the dimensional …
-
Application of Fluidic Lens Technology to an Adaptive Holographic Optical Element See-Through Auto-Phoropter
… addition, the system incorporates Shack-Hartmann wavefront sensing technology to identify the eye's wavefront error and corresponding prescription. Using the wavefront error information, the fluidic auto-phoropter nulls the eye's lower order wavefront error by applying the appropriate volumes to …
-
Οι μονοχρωματικές εκτροπές υψηλής τάξης του οφθαλμού κατά την παιδική ηλικία
… years). Ocular aberrations were measured using a wavefront aberrometer (COAS, AMO Wavefront Sciences, USA) at mesopic light levels (illuminance at cornea was 4 lux). Wavefront analysis was achieved for a 5 mm pupil. Statistical analysis was carried out for the right eye only. Results: Myopia rates …
-
Role of scheimpflug-based lens densitometry in preoperative assessment of age-related nuclear cataracts
… of the crystalline lens based on ray-tracing wavefront analysis and phacodynamics prediction. In this thesis, we have confirmed that Scheimpflugbased lens densitometry presented a strong association with aging, corrected distance visual acuity decrease, and slit lamp evaluation. A significant …
-
Μελέτη της ασφάλειας και αποτελεσματικότητας ενδοκερατοειδικών διαθλαστικών ενθεμάτων για την διόρθωση της πρεσβυωπίας
… visual acuity, refraction, contrast sensitivity, wavefront analysis, confocal analysis. Results: Mean uncorrected visual acuity for near (UNVA) in the operated eye improved from 20/50 to 20/32 after one week and 20/25 after one month and remained stable during the 12 follow-up months. The mean add …
-
Optimising the clinical analysis of retinal image quality in the human eye
… of this thesis was to validate and optimise wavefront analysers and a new clinical tool for the objective evaluation of intraocular scatter. The application of these methods in a clinical setting involving a range of conditions was also explored. The work was divided into two principal …
-
Vergleich der kornealen und okulären Aberrationen mittels kornealer Topographie und Wellenfront-Aberrometrie
Hintergrund: Bisher ist der Einfluß der kornealen und okulären Aberrationen noch unzureichend bekannt. Ziel der vorliegenden Dissertation war daher, die Vergleichbarkeit der kornealen und okulären Aberrationen mittels kornealer Topographie und Wellenfront-Aberrometrie zu prüfen. Insbesondere sollte …
-
Multifocusing seismic imaging of complex geological structures
… super common-midpoint bins, wavefield attributes analysis, multifocusing moveout correction, data enhancement/stacking, and prestack/poststack dip-independent RMS velocity analysis and migration. Our wavefield analysis uses a multidimensional differential evolution algorithm to simultaneously …