Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 57 for “"welded wire"”.
-
Evaluation of a Welded Wire Retaining Wall
… this paper is to evaluate the performance of a Welded Wire Retaining Wall and present design recommendations for its future use. Field data from the instrumentation of a Welded Wire Retaining Wall as well as laboratory data from a study of welded wire fabric as a reinforcing agent for soil was …
-
Tensile Strain Validation of Welded Wire Reinforcement
… historical concerns regarding the ductility of welded wire reinforcement (WWR). Recent changes in ACI 318-19 now require all grades of A615 and Grade 100 A706 nonprestressed steel reinforcement to have a ratio of tensile strength to yield strength greater than 1.10 and 1.17 respectively. …
-
Pullout Resistance of Welded Wire Mats Embedded in Soil
Welded wire mesh has been used in the past as soil reinforcement in the construction of reinforced soil embankments. Involved in the design of these embankments is the external and internal stability. The internal stability has two failure mechanisms; tension failure and pullout failure of the …
-
Finite Element and Pullout Test Performance of Welded Wire Mats
… paper reports on the pullout test performance of welded-wire reinforcing mats. A 126-foot high mechanically stabilized earth wall was constructed at Kennecott Utah Copper. In the lower half of the wall, single lengths of 50-foot long welded-wire mats were used. In the top half of the wall, two …
-
Behavior of Concrete Floor Slabs Reinforced With Welded Wire Fabric
Made available in DSpace on 2014-12-08T23:56:11Z (GMT). No. of bitstreams: 1 6500773.pdf: 11720590 bytes, checksum: ac3802a975c80a80c90eefaed783f2c9 (MD5) Previous issue date: 1964
-
The use of welded wire fabric as shear reinforcement in concrete lintels
… was to evaluate design assumptions in the use of welded wire fabric as web reinforcement in precast concrete lintels. Casting processes have made the use of conventional shear reinforcement in form of stirrups not possible. Welded wire fabric placed vertically in the longitudinal direction has …
-
Enhancing Ductility of One-Way Concrete Slabs Reinforced With Welded Wire Reinforcement
… an issue called strain localization in welded wire reinforced (WWR) members. This phenomenon reportedly concentrates strains at welded cross wire locations and severely limit ductility. Those that identified the phenomenon used it to imply that WWR is unsafe because it does not warn of …
-
Reinforced Concrete Shear Walls with Welded Wire Grids as Boundary Element Transverse Reinforcement
… the overall cost and duration of construction. Welded Wire Reinforcement (WWR) is available in the construction industry as concrete reinforcement in the form of welded wire fabric (WWF) manufactured from relatively small diameter wires in comparison to the bar sizes typically used in structural …
-
Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
… floor slabs reinforced with 6 x 6 W1.4/W1.4 welded wire fabric (WWF) and STRUX 90/40 synthetic macro fibers. Slabs were subjected to flexural strength tests and concentrated load tests while monitoring load, steel deck strains, and deflections. Test results obtained from this test program …
-
Characterization of cracks in bridge beams with welded wire fabric reinforcement using image processing
… allow the substitution of an equal area of Welded Wire Fabric (WWF) for the traditional vertical steel reinforcement. However, TxDOT does not provide details for the WWF substitution. A research project was conducted to study the behavior of WWF as shear reinforcement m the high shear …
-
Shear strength of prestressed concrete t-beams with welded wire fabric as shear reinforcement
… stirrups is difficult and time consuming. Welded wire fabric appears to provide a relatively economical alternative. In this study, the shear strength of prestressed T-beams reinforced with welded wire fabric as shear reinforcement is investigated. Thirteen large-scale bonded and unbonded …
-
Finite Element Modeling of Mechanically Stabilized Earth Walls Built with Welded Wire Wall Panels
… Mechanically Stabilized Earth (MSE) walls using welded wire wall panels was performed. The implementation of finite element modeling and analysis proved to be quite efficient in simulating the three-dimensional behavior of wall panels that are a part of MSE walls. The comprehensive finite element …
-
Strength and ductility of concrete columns reinforced with welded wire fabric and/or rebars.
… the characteristics of concrete confined by welded wire fabric. The column reinforcement consisted of only welded wire fabric, without the use of any reinforcing bars. The increase in confinement was relatively small. The ductility enhancement was also limited. It was concluded that, unless …
-
Behavior of Reinforced Lightweight Cellular Concrete Backfill for Mechanically Stabilized Earth Walls with Welded Wire Reinforcements
… is poorly understood. The pullout resistance of welded wire reinforcement within LCC is poorly understood as well. This research attempts to add knowledge of LCC behind MSE walls by (1) performing pullout tests on welded wire reinforcements, (2) defining the apparent friction coefficient versus …
-
Lateral Resistance of Pipe Piles Behind a 20-Foot-Tall MSE Wall with Welded-Wire Reinforcements
… of the wall. The MSE wall was constructed using welded-wire grid and ribbed strip inextensible reinforcements. This paper focuses on four lateral load tests conducted on steel pipe piles located behind a 20-ft section of MSE wall reinforced with welded-wire grids. Results showed that measured …
-
Pullout Strength of Welded Wire and Ribbed Strip Reinforcement in Lightweight Cellular Concrete Backfill Behind Mechanically Stabilized Earth Wall
… gap through performing pullout tests on welded wire and ribbed strip reinforcements in MSE walls to determine the pullout friction coefficient (F*), reinforcement pullout behavior, and LCC properties. A large-scale test box (10 feet wide x 12 feet long x 10 feet high) supported by a steel …
Page 1 of 3