Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 116 for “"wheatstone bridge"”

  1. Zinc Oxide Nanorod Based Ultraviolet Detectors with Wheatstone Bridge Design

    … based ultra-violet (UV) detectors having a Wheatstone bridge design with a high responsivity at room temperature and above, as well as a responsivity that was largely independent of the change in ambient conditions. The ZnO nanorods which acted as the sensing element of the detector were …

    arkansas Repository record for Zinc Oxide Nanorod Based Ultraviolet Detectors with Wheatstone Bridge Design (opens in a new tab)

  2. The effect of heating area and Wheatstone bridge materials on a thermally actuated MEMS viscosity sensor

    … area and the sensing material used in the Wheatstone bridge. To also improve the repeatability of the sensors and reduce sensor to sensor variation the fabrication process was improved. This included the use of SOI wafers and better diaphragm alignment through the use of a contact aligner …

    rit Repository record for The effect of heating area and Wheatstone bridge materials on a thermally actuated MEMS viscosity sensor (opens in a new tab)

  3. Strength and stiffness characteristics of unsaturated soils

    … of Goto et al. (1991) using a conventional full Wheatstone bridge circuit. An alternative circuit to the Wheatstone bridge circuit, the Anderson loop circuit, was introduced to improve the performance of LDT. LDTs were fabricated in identical fashion but with different circuits. Performances of …

    nanyang Repository record for Strength and stiffness characteristics of unsaturated soils (opens in a new tab)

  4. Sensor interface for body pressure monitoring device

    … system consists mainly of a multi-channel Wheatstone bridge, operational amplifier, analog-to-digital converter, multiplexer and voltage regulator. The multi-channel Wheatstone bridge is used to measure the resistance change of the sensors through the measure of the output voltage change of …

    nanyang Repository record for Sensor interface for body pressure monitoring device (opens in a new tab)

  5. Characterization of Effects of Mixed Neutron/Gamma Irradiation on NASA Glenn SiC Piezoresistive Pressure Sensors

    … of SiC piezoresistive pressure sensors in a Wheatstone bridge configuration is evaluated in gamma and mixed neutron/gamma radiation fields. The performance of a Si piezoresistive pressure sensor in a Wheatstone bridge configuration was also evaluated in the same radiation fields for …

    ohiolink Repository record for Characterization of Effects of Mixed Neutron/Gamma Irradiation on NASA Glenn SiC Piezoresistive Pressure Sensors (opens in a new tab)

  6. Reliability study on simple networks in the form of chains and rings

    … also able to prove one important feature of the Wheatstone Bridge Chain and explain the configurational dependence of the reliability of the Wheatstone Bridge Ring.</p> <p>Together with simulation results, we will show how symmetry can be related to the network reliability in this thesis. We will …

    hkust Repository record for Reliability study on simple networks in the form of chains and rings (opens in a new tab)

  7. Microforce sensor design and fabrication

    … built with build-in piezoresistors in a Wheatstone bridge circuit configuration.

    nanyang Repository record for Microforce sensor design and fabrication (opens in a new tab)

  8. Design of constraint-aware readout circuits for bridge sensor applications

    … (op-amp) clamping the voltage of sensing bridge output nodes, the change in bridge resistance is thus converted into signal current. This current is injected into an integrating capacitor. The ramping voltage of integrator is then converted into frequency through the associated comparator …

    nanyang Repository record for Design of constraint-aware readout circuits for bridge sensor applications (opens in a new tab)

  9. Field induced switching in multilayer rhombic magnetic rings

    … contact configurations known as "classical" and "wheatstone bridge" provide additional information on interactions that are occurring within the structures. It was found that both contact configurations were sensitive to similar changes in the devices, however, through different means of sensing. …

    mit Repository record for Field induced switching in multilayer rhombic magnetic rings (opens in a new tab)

  10. Integrated Micro-Origami Sensorics

    … As a proof of this concept, magneto-resistive Wheatstone bridge sensors are developed and integrated in the self-assembling platform at predefined rigid regions and integrated with an active matrix backplane circuit. This circuit, based on a-IGZO TFT technology, is specially designed for the …

    qucosa-diss Repository record for Integrated Micro-Origami Sensorics (opens in a new tab)

  11. Development and characterization of an impedance-based carbon sensor for the detection of catalyst coking in steam-methane and dry-methane reforming systems

    … environments. The sensor comprises of a Wheatstone bridge with two catalytic, non-percolating cermet resistive elements printed using an inkjet printer. As carbon begins to grow on the catalytic surface, the electrical conductivity of the catalytic material increases, which results in a …

    colo-mines Repository record for Development and characterization of an impedance-based carbon sensor for the detection of catalyst coking in steam-methane and dry-methane reforming systems (opens in a new tab)

  12. STUDY OF SELF-HEATING EFFECT OF MICROBOLOMETER INFRARED DETECTOR AND ITS COMPENSATION TECHNIQUE

    … using reference microbolometer arranged in a Wheatstone bridge read-out circuit. Finally, the concept is extended for application in focal plane arrays and a possible circuit configuration is given to achieve the compensation, which may enhance the performance of uncooled detector arrays.

    nus Repository record for STUDY OF SELF-HEATING EFFECT OF MICROBOLOMETER INFRARED DETECTOR AND ITS COMPENSATION TECHNIQUE (opens in a new tab)

  13. High efficiency dynamic pressure based flow measurement

    … sensors with strain gages are connected to a Wheatstone-Bridge. The resistance variation due to the strain changing in cantilever platform converts to voltage variation by the Wheatstone-Bridge. Signal amplification and filtering are carried out by a dedicated circuit board. The work was …

    concordia

  14. I. An isothermal titration microcalorimeter. II. Importance of micronutrients in nutrition. III. Zinc bibliography

    … heating controlled by a thermistor in an AC Wheatstone bridge circuit. The calorimeter was tested by measuring the heat of ionization of water and was found to produce data accurate to ± 0.1% where small samples are used such as in the investigation of many biological systems.

    byu Repository record for I. An isothermal titration microcalorimeter. II. Importance of micronutrients in nutrition. III. Zinc bibliography (opens in a new tab)

  15. Design and analysis of a resistively heated surgical probe

    … is accurately maintained and measured by using a Wheatstone bridge. The probe was embedded in an agar-water test medium and the temperature field emanating from the probe was measured using liquid crystal tapes. The experimental results compare within approximately 10% of a two-dimensional …

    nps Repository record for Design and analysis of a resistively heated surgical probe (opens in a new tab)

  16. Modelo de ashkin-teller de três cores na rede ponte de wheatstone

    … in the hierarquical lattice generated by the Wheatstone bridge using real space renormalization group approach. With such technique we obtain the phase diagram and its critical points with respective critical exponents v. This model presents four phases: ferromagnetic, paramagnetic and two …

    brazil-ufrn Repository record for Modelo de ashkin-teller de três cores na rede ponte de wheatstone (opens in a new tab)

  17. Lower confidence interval bounds for coherent systems with cyclic components

    … for series, parallel, series-parallel, and Wheatstone Bridge systems. The method determined to be most accurate can be combined with similar procedures for components that have continuous failure times and applied to yield a lower confidence interval procedures for the reliability of …

    nps Repository record for Lower confidence interval bounds for coherent systems with cyclic components (opens in a new tab)

  18. 2000-Atmosphere bulk-type dual-cavity MEMS pressure sensor

    … up to 200 MPa. Incorporating a half Wheatstone bridge consisting of two sensing piezoresistors and two relatively constant reference resistors to measure the biaxial compression induced by a hydrostatic pressure load, the sensor exhibits a sensitivity of 79 μV/V/MPa. However, the …

    hkust Repository record for 2000-Atmosphere bulk-type dual-cavity MEMS pressure sensor (opens in a new tab)

Page 1 of 6