Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 27 for “"wide linear range"”

  1. Peroxide Sensing Using Nitrogen-Doped and Platinum Nanoparticle-modified Screen-Printed Carbon Electrodes

    … of hydrogen peroxide. N-SPCEs exhibited a wide linear range (20 µM to 5.3 mM), reasonable limit of detection of 2.5 µM, with an applied potential of -0.4 V (vs. Ag/AgCl). We also demonstrate that nitrided-graphite can similarly be used as a platform for the deposition of electrocatalytic …

    etsu Repository record for Peroxide Sensing Using Nitrogen-Doped and Platinum Nanoparticle-modified Screen-Printed Carbon Electrodes (opens in a new tab)

  2. Biosensoriaus, skirto L-aminorūgščių koncentracijos nustatymui, kūrimas ir charakterizavimas /

    … respectively) and high sensitivity, low LOD and wide linear range for L-amino acids (0,77 µC/µM, 5,26 µM and 25-1500 µM, respectively). Moreover, the electrode demonstrated high stability and retained more than 90% of the initial activity after 30 days of storage. The designed biosensor was …

    vilnius Repository record for Biosensoriaus, skirto L-aminorūgščių koncentracijos nustatymui, kūrimas ir charakterizavimas / (opens in a new tab)

  3. A multimodal sensing patch for detection of muscle activities

    … allows high sensitivity of 0.41 kPa-1 and a wide linear range up to 70 kPa. The EMG measurement relies on a flexible dry electrode that is formed with a conductive nanocomposite of silver powders and elastomer. The rough surface of the flexible dry electrode improves conformal contact to the …

    iastate Repository record for A multimodal sensing patch for detection of muscle activities (opens in a new tab)

  4. Multi-functional polymer scaffolds as biosensors for detection of ethanol and organophosphorous pesticides and as fluorescent probes for cell imaging purposes

    … sensing system offering fast response time, wide linear range and low detection limit with a high sensitivity. The capability of the biosensor in determining ethanol content in alcoholic beverages was also demonstrated. In the second study, a novel amperometric biosensor based on a CP …

    metu Repository record for Multi-functional polymer scaffolds as biosensors for detection of ethanol and organophosphorous pesticides and as fluorescent probes for cell imaging purposes (opens in a new tab)

  5. Luminescent markers and labels in authentication and novel bioaffinity assays

    … is demonstrated with a smartphone application. Wide variety of marker luminophores can be used in the future, as camera technologies and computing power of the smartphones are constantly evolving. The results also show that cellulose as substrate displays weak long-lived photoluminescence …

    aalto Repository record for Luminescent markers and labels in authentication and novel bioaffinity assays (opens in a new tab)

  6. Impact of in vitro Tear Film Composition on Lysozyme Deposition and Denaturation

    … assay demonstrated high sensitivity and a wide linear range of detection, which covers the amount of lysozyme typically extracted from contact lenses. Using this assay, lysozyme activity on both silicone hydrogel materials was lower in the presence of lipids in the ATS. In addition, …

    waterloo Repository record for Impact of in vitro Tear Film Composition on Lysozyme Deposition and Denaturation (opens in a new tab)

  7. Nanoparticle-based electrochemical sensors for the detection of lactate and hydrogen peroxide

    … were evaluated to determine their sensitivity, linear range, detection limit, and storage stability. In addition, practical applicability of the sensors was studied in human serum. The chronoamperometry results showed that the PdCu/SPCE sensors yielded a high sensitivity (396.7 µA mM -1 cm-2), a …

    purdue-thes Repository record for Nanoparticle-based electrochemical sensors for the detection of lactate and hydrogen peroxide (opens in a new tab)

  8. Design and Synthesis of Graphene-based Nanocomposites for Sensing and Medical Applications

    … cm-2), a low limit of detection (2.6 μM), and a wide linear range for the identification of Hyp in various media. The synthesized gold and fluorine-doped reduced graphene oxide nanocomposites showed high-performance for the detection of SMBS in different digestive fluids (e.g., simulated salivary …

    guelph Repository record for Design and Synthesis of Graphene-based Nanocomposites for Sensing and Medical Applications (opens in a new tab)

  9. Integrated Biorecognition and Dual-Signal Transduction Strategies for Oligonucleotide-Based Biomolecular Detection in Complex Media

    … that enabled a low limit-of-detection (5 fM), a wide linear range (1 fM – 100 pM), and the ability to discern between single and double base-mismatched nucleic acid sequences. In parallel, we also detail the development of an EC biosensor featuring dynamic DNA motifs, capable of reagentless, …

    mcmaster Repository record for Integrated Biorecognition and Dual-Signal Transduction Strategies for Oligonucleotide-Based Biomolecular Detection in Complex Media (opens in a new tab)

  10. High-performance Super-capacitive Pressure Sensor with Both High Sensitivity and Wide Linear Sensing Range

    … of challenges, such as low sensitivity, narrow linear sensing range, low pressure-resolution and non-well-defined structure inevitably confines the extensive application of the capacitive type of flexible sensors. A key challenge in pressure sensor design lies in the trade-off between achieving …

    unsw Repository record for High-performance Super-capacitive Pressure Sensor with Both High Sensitivity and Wide Linear Sensing Range (opens in a new tab) Embargoed

  11. Determination of DNA via Resonance Light Scattering technique using new probes derived from ruthenium ligands complexes and investigation of their binding mode

    … 2a was pH 3. The pH optimum lies in the basic range for the other dinuclear RLCs. The LOD of 2b was calculated to be 1.6 ng mL-1 for ct-DNA and 2.7 ng mL-1 for fs-DNA with a wide linear range of 30 - 1800 ng mL-1 under optimum conditions. The method presented here does not require surfactants …

    regensburg-diss Repository record for Determination of DNA via Resonance Light Scattering technique using new probes derived from ruthenium ligands complexes and investigation of their binding mode (opens in a new tab)

  12. Development of glucose biosensors using nanostructured composites

    … The sensitivity of MFH biosensor studied in the range 2-12 mM of glucose is found to fall in the region of 15.31 μA mM−1 cm−2 with low detection limit of 25 μM. The biosensor based on CH platform exhibited a broad linear behaviour when glucose in the range 1-20 mM is studied, with high …

    sheffield-hallam Repository record for Development of glucose biosensors using nanostructured composites (opens in a new tab)

  13. Desenvolvimento de biossensores à base de filmes poliméricos, nanotubos de carbono e nanopartículas de ouro

    … V. The Tyr-BMIMMWCNTs- DHP/GCE biosensor showed wide linear range, good repeatability, sensitivity and stability and, the biosensor was successfully applied in the determination of catechol in natural water samples. The second developed biosensor was based on the modification of a GCE with gold …

    brazil-ufscar Repository record for Desenvolvimento de biossensores à base de filmes poliméricos, nanotubos de carbono e nanopartículas de ouro (opens in a new tab)

  14. Predicting the cell-wall compositions of Pinus radiata D. Don woods using mid- and near infrared spectroscopies

    … techniques. In this study, a training set with a wide linear range of lignin contents and monosaccharide compositions was established and the wood cell-wall components were determined using a two-stage sulfuric acid hydrolysis and high-performance anion-exchange chromatography with pulsed …

    auckland-ms Repository record for Predicting the cell-wall compositions of Pinus radiata D. Don woods using mid- and near infrared spectroscopies (opens in a new tab)

  15. Development of Electrochemical Sensors Based on Polymer Nanocomposites for Sensing of Neurotransmitter Dopamine

    … for a healthy individual and in the nanomolar range for patients with Parkinson’s disease; while the concentration of the main severe interferents, e.g. ascorbic acid, is several orders of magnitude greater. Moreover, ascorbic acid undergoes oxidation within the same potential window as …

    calgary Repository record for Development of Electrochemical Sensors Based on Polymer Nanocomposites for Sensing of Neurotransmitter Dopamine (opens in a new tab)

  16. The Development of Sorbent Materials for Extraction of Critical Elements and Emerging Contaminants

    … reproducibility, low detection limits, and a wide linear range and also showed practicability for real sample analysis.In the fourth chapter, a new sorbent based on magnetic nanoparticles was developed with the aim to remove pharmaceutical and personal care products from environmental water. …

    ohiolink Repository record for The Development of Sorbent Materials for Extraction of Critical Elements and Emerging Contaminants (opens in a new tab)

  17. Analysis of Metabolites and Therapeutics for Toxic Inhaled Agent Exposure

    … limit of 0.02 mg/kg and calibration curve linearity extending from 0.06‒1.51 mg/kg (R2 = 0.998 and overall %RA >90). The accuracy and precision (100±9% and < 10% relative standard deviation, respectively) of the method were outstanding. The validated method was successfully able to detect …

    sdstate Repository record for Analysis of Metabolites and Therapeutics for Toxic Inhaled Agent Exposure (opens in a new tab)

  18. Development of Analytical Methods for Toxic Inhaled Hazards (TIH) and Their Metabolites

    … The method features an excellent LOD of 25 nM, a wide linear range (0.05–200 μM), and good accuracy and precision. The method was successfully applied to determine A-967079 from treated animals and it may facilitate the development of A-967079 as a therapeutic agent against the noxious effects of …

    sdstate Repository record for Development of Analytical Methods for Toxic Inhaled Hazards (TIH) and Their Metabolites (opens in a new tab)

  19. Orthogonal fluxgate type magnetic microsensors with wide linear operation range

    … type magnetic sensors operating within a wide linear operation range. Fluxgate type magnetic sensors are powerful devices due to their high sensitivity, low offset, and high temperature stability. Unfortunately, their linear operation range is limited, since an attempt to increase the …

    epfl Repository record for Orthogonal fluxgate type magnetic microsensors with wide linear operation range (opens in a new tab)

  20. Novel sensors for detection of anti-asthma drugs in pharmaceutical formulations

    … (LOQ) of 0.0120 µM, over the concentration range of 0.05- 3.9 µM. In addition, the MWCNTs-IL-L-lysine-GCE exhibited outstanding electro-catalytic activity including excellent reproducibility, with LOD and LOQ of 0.0214 μM and 0.3016 μM, respectively, for prednisolone (PDN) detection. …

    dut Repository record for Novel sensors for detection of anti-asthma drugs in pharmaceutical formulations (opens in a new tab)

Page 1 of 2