Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"wind uplift"”.

  1. Wind Uplift Resistance of Roof Edge Components

    … various weather elements, such as snow, rain and wind. Roofs are normally composed of several components such as insulation, barriers and water proofing membrane. A roof edge is the perimetric part of a roof that serves as termination for roof components. In generic terms, a roof edge system is …

    ottawa-retro Repository record for Wind Uplift Resistance of Roof Edge Components (opens in a new tab)

  2. Wind Uplift Performance Evaluation of Adhesive Applied Roofing Systems

    Understanding how a roof performs under wind action is crucial to improve the roof design. The present study contributes to an ongoing collaborative research and development project, "Evaluation of wind uplift resistance of Adhesive Applied Roofing Systems (AARS)". The objectives of the project are …

    ottawa-retro Repository record for Wind Uplift Performance Evaluation of Adhesive Applied Roofing Systems (opens in a new tab)

  3. Numerical evaluation of low-slope roofs for wind uplift

    … Canada in the evaluation of roofing systems for wind uplift design. Accomplishments are grouped in two tasks. Task one provides development of a knowledge-based design module for the estimation of wind load distribution on roofs. Task two, numerical modeling using finite element methods and …

    ottawa-retro Repository record for Numerical evaluation of low-slope roofs for wind uplift (opens in a new tab)

  4. Numerical and Experimental Investigations for Wind Uplift Force on Flat Roofing System

    … failures that have occurred through the years. Wind-induced damage on flat roofs is a common problem for low-rise buildings and much of this damage is initiated when the steel deck roof fails, leading to the overall roofing system collapse. The FM (Factory Mutual) design recommendations, which …

    ottawa-retro Repository record for Numerical and Experimental Investigations for Wind Uplift Force on Flat Roofing System (opens in a new tab)

  5. Finite Element Analysis of the Wind - Uplift Resistance of Roof Edge Components

    Wind-induced damages on low-slope roofs are a major and common problem that many buildings located in high wind areas suffer from. Most of these damages are initiated when the metal roof edge fails first, leading to overall roof failure. This is because peak wind pressures occur at the edges and …

    ottawa-retro Repository record for Finite Element Analysis of the Wind - Uplift Resistance of Roof Edge Components (opens in a new tab)

  6. Direct Strength Method for the Flexural Design of Through-Fastened Metal Building Roof and Wall Systems under Wind Uplift or Suction

    … of metal building roof and wall systems under uplift and suction wind loading is complicated because the laterally unbraced purlin and girt's free flange is compressed, and the cross-section rotates due to the shear flow. The objective of this thesis is to introduce a Direct Strength Method …

    vt Repository record for Direct Strength Method for the Flexural Design of Through-Fastened Metal Building Roof and Wall Systems under Wind Uplift or Suction (opens in a new tab)

  7. Behaviour of Cold-formed Steel Claddings under Static and Constant Amplitude Cyclic Wind Loading

    … and wall claddings are subjected to significant wind uplift or suction pressure during high wind events. In New Zealand, the strong prevailing winds makes this a common occurrence. Suction pressure is generated by turbulence of the wind flow around the building which can vary both spatially and …

    auckland-ms Repository record for Behaviour of Cold-formed Steel Claddings under Static and Constant Amplitude Cyclic Wind Loading (opens in a new tab)

  8. Performance evaluation of mechanically attached roofing systems

    … Keeping the roofs in place against high wind events is a challenging task for architects and roof designers. There are two stages in the design process: first, a comprehensive understanding of the wind induced loads on the roof system and, second, an accurate estimation of the system …

    ottawa-retro Repository record for Performance evaluation of mechanically attached roofing systems (opens in a new tab)

  9. Adhesive Applied Roofing System Resistance Evaluation and its Quantification

    … of AARS are integrated using adhesives. Wind flow creates suction over a low-slope roof, which exerts uplift forces on the roof system. The components of AARS are subjected to the combined action of tensile and shearing forces due to the dynamic wind uplift action. As part of a research …

    ottawa-retro Repository record for Adhesive Applied Roofing System Resistance Evaluation and its Quantification (opens in a new tab)

  10. Development of a pullout test method for adhesive applied roofing systems

    … exists for the evaluation or characterization of wind uplift resistance of Adhesive Applied Roofing Systems (AARS). It was determined that a pullout test method -- a test in which the adhered components of roofing samples were subjected to tensile loading until failure -- could be used to quantify …

    ottawa-retro Repository record for Development of a pullout test method for adhesive applied roofing systems (opens in a new tab)

Page 1 of 2