Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"winding faults"”.
-
Fault Detection of HVDC Transformer Windings using Impedance Protection
… components in power systems. Transformer winding faults are among the most frequent issues in transformers. Since winding faults are inherently aggravated, transformer winding short circuits need to be detected at an early stage. The existing transformer protection methods encounter …
-
A FAULT DETECTION AND DIAGNOSIS STRATEGY FOR PERMANENT MAGNET BRUSHLESS DC MOTOR
… and Diagnosis (FDD) strategy for detecting motor faults at their inception. Two FDD strategies were considered involving wavelets and state estimation. Bearing faults and stator winding faults, which are responsible for the majority of motor failures, are considered. These faults were physically …
-
Detection of Inter-turn Winding Fault in Single-phase Transformers Using a Terminal Measurement Based Modeling Technique
… providing power to the domestic consumers. Any faults in the single-phase transformers leading to power outages or catastrophic power systems failures cause huge loss of capital, property and in some cases even human casualties. Gradual deterioration of the electrical winding insulation …
-
Fault modelling and analysis of permanent magnet machines for offshore wind power application
… units. Therefore, it is necessary to study the faults of wind generators and try to reduce their downtime by detecting their faults at an early stage and then implementing effective maintenance. Among all the faults of these wind generators, the winding fault, as the second most frequent fault, …
-
Operation of interior permanent magnet synchronous machines with fractional slot concentrated windings under both healthy and faulty conditions
… fault tolerant fractional slot concentrated winding machine designs experiencing stator winding insulation failure are evaluated. Two of the machines are designed with double-layer windings and one with single-layer. The single-layer fractional slot concentrated winding design is shown most …
-
ADVANCEMENTS IN TIME-DOMAIN MODELING OF POWER SYSTEM DISTURBANCES
… is a short circuit internal to the transformer windings and the second is a Geomagnetic Disturbance (GMD), an external cosmic event that may magnetically saturate the transformer core and impact the power grid on a larger scale. In order to model an internal winding fault for both turn-to-turn …
-
Transformer modeling ATP : internal faults & high-frequency discretization
… of several aspects such as internal winding faults, which is a common cause of transformer failure. It is also important to adequately represent the transformer at frequencies higher than the power frequency for a more accurate simulation of switching transients since these are a well …
-
Using Intrinsic 3rd Harmonics for Large Synchronous Generator Insulation Fault Condition Monitoring
… for detecting generator stator insulation faults using intrinsic third harmonics. Based on two-port network theory, a mathematical model is derived and presented in this thesis. Data from offline experiments has been analyzed to verify the technique’s effectiveness. Additionally, online …
-
Advanced Fault Detection Methods for Permanent Magnets Synchronous Machines
… of the key aspects to cover such demand. Stator winding faults are known to be the second most common type of fault, after bearing fault. An extensive literature review has shown that, although a number of methods has been proposed to address this type of fault, no tool of general application, …
-
Electromagnetic Analysis of Stator Ground Faults in Synchronous Generators
There are many stator ground faults protection schemes available in the industry. These schemes relatively perform well in detecting the faults in the stator winding. The protection of the neutral point vicinity is the challenge because of the low voltage induced in that area. The 100% stator …
-
Induction Machine Modeling and Emulation for Asymmetrical Conditions
… factors, unbalance caused by internal faults can occur. Stator windings, rotor bars, and end rings are the most common internal faults. Such faults not only reduce the machine working efficiency and cause excessive heating but also cause potential hazards for continuous work and safety. …
-
A MICROPROCESSOR-BASED SYSTEM FOR PROTECTION OF POWER TRANSFORMERS
… the thesis. Digital algorithms that can detect winding faults in power transformers are described in the thesis. The algorithms use non-linear models of a transformer to determine its health. The algorithms take the non-linearity and hysteresis of the transformer core into account, however, …
-
Detection of Permanent Magnet DC Motor Failure Due to Brush Wear Using Parameter Estimation and Statistical Analysis
… without maintenance will inevitably occur. Motor faults can be classified as electrical or mechanical, both with wide ranges of causes. Electrical failure includes stator or rotor winding faults, inverter faults, position of sensor faults in brushless motors, bearing faults, and brush faults. …
-
Current based condition monitoring of electromechanical systems. Model-free drive system current monitoring: faults detection and diagnosis through statistical features extraction and support vector machines classification.
… (rotor, bearings eccentricity) and stator winding faults in a 3-phase induction motors from observation of motor line current supply input. The main aim is to avoid the consequence of unexpected failure of critical equipment which results in extended process shutdown, costly machinery …
-
Condition Monitoring and Fault Diagnosis of Induction Machine Using Artificial Intelligence Methods and Empirical Mode Decomposition
… asymmetries and vibrations due to machine faults. Hence, this project focuses on two fault detection techniques, namely, vibration signature and MCSA. There are a number of issues to address in the formulation of a reliable fault detection and diagnosis scheme: 1. definition of a single …
-
Fault-Tolerant Strategies for Multiphase Open-End Winding Permanent Magnet Synchronous Machine Drive System
… failures (open- and short-circuit) and phase winding faults (open- and short-circuit). The thesis primarily addresses challenges associated with the dual inverter fed machine from a common dc-link. This thesis proposes a novel online dc-link capacitor condition monitor algorithm that …
-
Power-hardware-in-the-loop (PHIL) based Emulation of Faults in Induction Machines
… speed. An induction machine has three common faults: stator inter-turn faults, rotor broken bars, and bearing faults. These faults can affect the industry's productivity and cause outages in the transportation industry. For example, an induction motor failure in a freight locomotive can cause …
-
Induction Machine Emulation for Supply Faults
… machine undergoes wear and tear and may develop faults such as winding faults, bearing faults, or rotor eccentricity etc. If such machines are being emulated, their corresponding impact on the driving inverter, controller and power system can be studied without implementing these faults on a …
-
Modelování a řízení střídavých elektrických pohonů při poruše
Dizertační práce se zabývá modelováním a řízením elektrických pohonů během poruchových stavů. Práce se obzvláště zaměřuje na více-fázové motory. První část práce se zabývá matematickými rovnicemi obecného více-fázového motoru a následným odvozením n-krát troj-fázového zapojení motoru. Modely v dq …