  1. Implementation of Window Shading Models into Dynamic Whole-Building Simulation

    … spaces to become highly sensitive to solar gain. Shading devices such as operable slat-type louver blinds are very effective in controlling solar gain, yet their impact on peak cooing loads and annual energy consumption is poorly understood. With the ever-increasing role of building energy …

    waterloo Repository record for Implementation of Window Shading Models into Dynamic Whole-Building Simulation (opens in a new tab)

  2. Evaluation And Control of Window Shading for Occupant Comfort And Energy Efficiency

    … use, due to their highly glazed envelopes. Smart window shading control devices have the potential to mitigate these problems; however, their application has been limited thus far. To promote the wider adoption of smart window shading devices, the first two research questions of this thesis focus …

    toronto-retro Repository record for Evaluation And Control of Window Shading for Occupant Comfort And Energy Efficiency (opens in a new tab)

  3. Empirical validations of the daylighting/window shading/solar gains models in building energy simulation programs

    … programs when modeling glazing units and windows with and without shading devices and daylighting. Program outputs were compared with data from experiments performed at two research facilities designed for these types of studies;Six experiments were performed in a test cell located on the …

    iastate Repository record for Empirical validations of the daylighting/window shading/solar gains models in building energy simulation programs (opens in a new tab)

  4. Window Shading for Cooling Load Reduction in Commercial Building Retrofits in Tropical Climates: The Case of Accra, Ghana and Miami, Florida

    … office space with an area of 20m2, one without window shading and one with a fixed louvered overhang. The study explored the impact of the louvered overhang with projection factor of 0.7 for an east, west and south-facing window on cooling load reduction and daylighting performance for office …

    oregon Repository record for Window Shading for Cooling Load Reduction in Commercial Building Retrofits in Tropical Climates: The Case of Accra, Ghana and Miami, Florida (opens in a new tab)

  5. O impacto do ofuscamento no (DES) uso da luz natural em ambientes do tipo escritório em baixa latitude

    External window shading is not enough for the occupants of air-conditioned office buildings to maintain the curtains and blinders opened, to enjoy daylighting, exterior view, environment comfort, and natural ventilation eventually, at low latitudes, such as Natal-RN (latitude -5.8; longitude …

    brazil-ufrn Repository record for O impacto do ofuscamento no (DES) uso da luz natural em ambientes do tipo escritório em baixa latitude (opens in a new tab)

  6. A influência de decisões arquitetônicas na eficiência energética do Campus vol. 1/UFRN

    … In this model, different solutions of roofs, shading devices, walls and external colors were simulated. The results of all simulation models suggest a high influence of thermal loads due to the incidence of solar radiation on windows and surfaces, which highlights the importance of window …

    brazil-ufrn Repository record for A influência de decisões arquitetônicas na eficiência energética do Campus vol. 1/UFRN (opens in a new tab)

  7. Development of Solar-Optical Models for Energy Performance Analysis of Draperies in Complex Fenestration Systems

    Window coverings have been used for many years to provide protection from undesired environmental conditions and to regulate indoor conditions. Models for complex fenestration systems (CFS), a term coined in the early 90’s in light of optical and thermal complexity of shading elements, are …

    waterloo Repository record for Development of Solar-Optical Models for Energy Performance Analysis of Draperies in Complex Fenestration Systems (opens in a new tab)

  8. Bistable Hybrid Textile Structures: Combining Knitting and 3D Printing Fabrication Methods for Adaptive Building Skin Applications

    … studies of bistable material’s state changes in window shading area. Inspired by the natural movement of plants like the Morning Glory Flower and Shamrock, this research introduces novel assembly strategies for architectural applications such as an external layer of building skin performs as a …

    calgary Repository record for Bistable Hybrid Textile Structures: Combining Knitting and 3D Printing Fabrication Methods for Adaptive Building Skin Applications (opens in a new tab)

  9. INFLUENCE OF ENVIRONMENTAL DESIGN FACTORS ON PERCEPTION AND PERFORMANCE OF INDOOR OCCUPANTS

    … factors, including sky conditions, view types, window shading conditions, façade design elements like patterned solar screens, and the layout of office spaces, particularly within the framework of Activity-Based Working (ABW) environments.The initial phase of the study focuses on how …

    oregon Repository record for INFLUENCE OF ENVIRONMENTAL DESIGN FACTORS ON PERCEPTION AND PERFORMANCE OF INDOOR OCCUPANTS (opens in a new tab)

  10. Simulação de desempenho luminoso para salas de aula em Natal-RN

    … The classrooms dimensions are 7.20mx 7.20m, with windows-to-wall-ratio (WWR) of 20%, 40% and 50%, and with different shading devices, such as standard horizontal overhang, sloped overhang, standard horizontal overhang with side view protection, standard horizontal overhang with a dropped edge, …

    brazil-ufrn Repository record for Simulação de desempenho luminoso para salas de aula em Natal-RN (opens in a new tab)

  11. IMPROVING ENERGY USE, DEMAND AND VISUAL COMFORT IN COMMERICAL BUILDINGS USING LIGHTING AND SHADING CONTROLS

    Windows provide occupants with natural light and a view of the outside, enhancing productivity, which is important as people spend approximately 90% of their time indoors. This is especially the case during and after the COVID-19 pandemic. Automated controls for window shading systems can be used …

    msu Repository record for IMPROVING ENERGY USE, DEMAND AND VISUAL COMFORT IN COMMERICAL BUILDINGS USING LIGHTING AND SHADING CONTROLS (opens in a new tab)

  12. Thermal and structural performances of insulated cavity rammed earth wall houses.

    … and energy loads were quantified, including the window size in each wall, window shading, window construction type, ventilation rate, the amount of thermal mass and insulation thickness. Also, the life-cycle cost of an ICRE wall house was minimised by optimising these key design parameters.

    adelaide Repository record for Thermal and structural performances of insulated cavity rammed earth wall houses. (opens in a new tab)