Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"wire mesh sensor"”

  1. Impedance wire-mesh sensor for multiphase flows: contributions to an improved measurement accuracy

    … However, to date, there is no universal sensor that can directly measure all the required flow parameters over the full range of all flow conditions. Therefore, several strategies have been developed to solve this problem. For pure measurement of fluid composition and mixture volume flow, …

    qucosa-diss Repository record for Impedance wire-mesh sensor for multiphase flows: contributions to an improved measurement accuracy (opens in a new tab)

  2. Implementation of Wire Mesh Sensor Principles into New Needle Probe for Characterization of Two-Phase Flow Parameters

    … and weaknesses. One such technique, the wire mesh sensor, which can measure the local instantaneous void fraction over an entire cross section of interest at very high sampling rates, will be employed in the full-scale facility. Using this sensor in a rod bundle flow channel introduces …

    tamu Repository record for Implementation of Wire Mesh Sensor Principles into New Needle Probe for Characterization of Two-Phase Flow Parameters (opens in a new tab)

  3. Void fraction measurements in large (0.3 m) diameter bubble column using Wire Mesh Sensor and Pressure transducers- Effect of sparger

    … a 30 cm diameter cylindrical bubble column using Wire Mesh Sensor (WMS) tomography and Pressure Transducers. Pair of WMS sensors, with a 64×64 wire configuration of each sensor, were installed which are separated by a distance along the axis of the bubble column. Wire Mesh Sensors and PTs Data …

    cuny Repository record for Void fraction measurements in large (0.3 m) diameter bubble column using Wire Mesh Sensor and Pressure transducers- Effect of sparger (opens in a new tab)

  4. Experimental Analysis of Fluid Dynamics and Chemical Reaction in Dense Bubbly Flows

    … (UFXCT). Additionally, the minimally intrusive wire-mesh sensor was qualified to assess chemical species concentrations during chemical absorption of CO2 and to derive local mass transfer related parameters. Among the global description of the fluid dynamics also local parameters of the …

    qucosa-diss Repository record for Experimental Analysis of Fluid Dynamics and Chemical Reaction in Dense Bubbly Flows (opens in a new tab)

  5. Circuito integrado de condicionamento de sinais para sensores wire-mesh aplicados ao monitoramento de escoamentos multifásicos

    … compared to established tomographic techniques, wire-mesh sensors were developed over the last decade. These sensors, which are inserted inside pipelines, are composed of an electrode mesh that performs electric impedance measurements, which can be converted in fluid electrical properties. …

    brazil-ufrn Repository record for Circuito integrado de condicionamento de sinais para sensores wire-mesh aplicados ao monitoramento de escoamentos multifásicos (opens in a new tab)

  6. Void fraction measurements in a large (0.3 m) diameter bubble column using Wire Mesh Sensors and Pressure Transducers: Effect of Spargers

    … a 30 cm diameter cylindrical bubble column using Wire Mesh Sensor (WMS) tomography and Pressure Transducers. Pair of WMS sensors, with a 64×64 wire configuration of each sensor, were installed which are separated by a distance along the axis of the bubble column. Wire Mesh Sensors and PTs Data …

    cuny Repository record for Void fraction measurements in a large (0.3 m) diameter bubble column using Wire Mesh Sensors and Pressure Transducers: Effect of Spargers (opens in a new tab)

  7. Development of a Fast X-ray Line Detector System for Two-Phase Flow Measurement

    … over the conventional methods such as the multi-sensor conductivity probe, wire-mesh sensor, impedance void meter, or direct optical imaging. The X-ray densitometry technique is non-intrusive, insensitive to flow regime changes, capable of measuring high temperature or high-pressure flows, and …

    vt Repository record for Development of a Fast X-ray Line Detector System for Two-Phase Flow Measurement (opens in a new tab)

  8. Experimental Investigation of Two-Phase (Gas/Liquid) Flow in Intermediate Sized, Horizontal and Inclined Pipes

    … instrumentation, flow condition monitoring sensors and a robust flow supply, transmission and storage system. The test fluids employed were air (1.2 kg/m3, 2.0 × 104Pa·s ) and water (998 kg/m3, 0.001 Pa·s, 0.072 N/m). All tests were operated at ambient temperature and pressure, …

    south-carolina Repository record for Experimental Investigation of Two-Phase (Gas/Liquid) Flow in Intermediate Sized, Horizontal and Inclined Pipes (opens in a new tab)

  9. Impedance Sensors for Fast Multiphase Flow Measurement and Imaging

    … has been investigated. Three different impedance sensor systems to quantify and monitor multiphase flows have been developed, implemented and metrologically evaluated. The first one is a complex permittivity needle probe which can detect the phases of a multiphase flow at its probe tip by …

    qucosa-diss Repository record for Impedance Sensors for Fast Multiphase Flow Measurement and Imaging (opens in a new tab)

  10. A study of gas lift on oil/water flow in vertical risers

    … flow meter, single beam gamma densitometer and wire-mesh sensor (WMS) were employed for investigating the flow characteristics. For the experiments of gas/liquid (air/water) two-phase flow, flow patterns of Bubbly, slug, churn flow regimes and transition regions were identified under the …

    cranfield Repository record for A study of gas lift on oil/water flow in vertical risers (opens in a new tab)

  11. Study of hydrodynamics in a REFLUX™ Flotation cell using multiphase flow sensors

    … within the RFC™ through the utilisation of sensors, namely the Wire-mesh sensor (WMS) and the Process Microscope (PM) to characterize hydrodynamics within the RFC™ in two-phase (gas and liquid) and three-phase (gas, liquid, and solid). The study focuses on three main aspects: (i) validation …

    qucosa-diss Repository record for Study of hydrodynamics in a REFLUX™ Flotation cell using multiphase flow sensors (opens in a new tab)

  12. Special Instrumentation for Two-Phase Flow

    … two-phase flow has been performed by means of a Wire Mesh Sensor. Local, chordal, cross-section void fraction values are derived from the sensor data in a wide range of phases superficial velocities, and a new signal methodology, able to characterize the flow in terms of phases distribution (flow …

    poli-torino Repository record for Special Instrumentation for Two-Phase Flow (opens in a new tab)

  13. Experimental Evaluation of Gas Retention in Two-Phase Flows relevant to Pool Scrubbing in FCVS

    … instrumentation utilized for this purpose were wire-mesh sensors in two different facilities, TRISTAN and ISOLDE, at the Paul Scherrer Institut. Furthermore, a new methodology for high-speed shadowgraphy was proposed and applied to measure droplet sizes inside the throat of self-priming Venturi …

    ethz Repository record for Experimental Evaluation of Gas Retention in Two-Phase Flows relevant to Pool Scrubbing in FCVS (opens in a new tab)

  14. Measurements in Horizontal Air-water Pipe Flows Using Wire-mesh Sensors

    … the performance and measurement uncertainty of wire-mesh sensors in different air-water flow regimes in horizontal pipes. It also presents measurements of void fraction and interfacial velocity in such flows. It was found that the interfacial velocity measurements of the wire-mesh sensors were …

    ottawa-retro Repository record for Measurements in Horizontal Air-water Pipe Flows Using Wire-mesh Sensors (opens in a new tab)