Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"wood frame structures"”

  1. Damage analysis and mitigation for wood-frame structures subjected to tornado loading

    … occurrence rates. Five different residential wood-frame building archetypes were designed at each of the locations based on current residential building code and/or practice. Fragilities for the roof sheathing, truss to wall top-plate, and wall-to-foundation connections were developed for each …

    colostate Repository record for Damage analysis and mitigation for wood-frame structures subjected to tornado loading (opens in a new tab)

  2. NONLINEAR NUMERICAL SIMULATION STUDY AND REGIONAL-SCALE SEISMIC RESILIENCE ASSESSMENT OF DEFICIENT WOOD-FRAME STRUCTURES RETROFITTED WITH SELF-CENTERING VISCOELASTIC DAMPERS

    Timber structures are among the most favorite types for constructing low- to mid-rise buildings. Many older wood-frame buildings were not designed to meet the current seismic provisions, and are considered as wood-frame buildings with soft story deficiency. Such residential buildings with three- …

    maryland Repository record for NONLINEAR NUMERICAL SIMULATION STUDY AND REGIONAL-SCALE SEISMIC RESILIENCE ASSESSMENT OF DEFICIENT WOOD-FRAME STRUCTURES RETROFITTED WITH SELF-CENTERING VISCOELASTIC DAMPERS (opens in a new tab)

  3. Reliability-based design for Japanese timber structures using Canadian S-P-F dimension lumber

    Reliability levels of Japanese 2x4 wood frame structures were evaluated using lumber property data derived from evaluation of Canadian Spruce-Pine-Fir dimension lumber. The evaluations were made using the "Standard for Limit States Design of Steel Structures (Draft)", which was newly published by …

    ubc Repository record for Reliability-based design for Japanese timber structures using Canadian S-P-F dimension lumber (opens in a new tab)

  4. Seismic assessment of a hybrid light wood-frame structure connected to a balloon-type CLT core

    Light wood-frame structures are the most common type of construction for residential and low-rise buildings in North America. The 2015 edition of the National Building Code of Canada has increased the height limit for light wood-frame construction from 4 to 6 stories. With the increase in building …

    uvic Repository record for Seismic assessment of a hybrid light wood-frame structure connected to a balloon-type CLT core (opens in a new tab)

  5. Effective wind area for the design of roof sheathing under wind loading

    Wood-frame structures are a popular choice for construction in North America. Due to their sensitivity to severe wind events, the design of these structures under wind loading is of particular importance. One of the issues with wind loading on cladding elements like roof sheathing is the …

    uwo Repository record for Effective wind area for the design of roof sheathing under wind loading (opens in a new tab)

  6. Loss analysis and loss based seismic design for woodframe structures

    Light frame wood structures serve as the vast majority of construction type for residential structures throughout North America. This type of structure utilizes mainly wood shearwalls and a joist-sheathing floor system to resist the live and dead loads. Compared to concrete and steel structures, …

    colostate Repository record for Loss analysis and loss based seismic design for woodframe structures (opens in a new tab)

  7. Monotonic Testing of Steel Anchor Straps for Alternative Installation Methods in Wood Frame Shear Walls

    Metal wood-connection hardware straps are sometimes installed in ways not intended by the manufacturers; in particular, a shear-wall anchor strap which was manufactured to be used in straight alignment to connect a post above a particular floor of a building to a post below that floor may instead …

    sjsu Repository record for Monotonic Testing of Steel Anchor Straps for Alternative Installation Methods in Wood Frame Shear Walls (opens in a new tab)

  8. Performance Assessment and Development of Prescriptive Design Standards for Wood-Frame Residential Structures Under Extreme Wind Loads

    High-wind events cause significant damage to structures and property; in particular, light-frame wood homes are abundant and especially vulnerable. Canadian homes are built to prescriptive standards that are based on historical construction methods and have remained relatively unchanged …

    uwo Repository record for Performance Assessment and Development of Prescriptive Design Standards for Wood-Frame Residential Structures Under Extreme Wind Loads (opens in a new tab)

  9. Performance of high-capacity light wood-frame shear walls with multiple rows of nails: Experimental and numerical study

    … the increase of building height limit for light wood-frame construction up to six storeys and the increase of seismic response spectra in national building code of Canada, stronger shear wall systems have been facing higher demands, especially for mid-rise wood-frame buildings located in high …

    uvic Repository record for Performance of high-capacity light wood-frame shear walls with multiple rows of nails: Experimental and numerical study (opens in a new tab)

  10. Seismic evaluation of high-capacity shear walls used in mid-rise light wood frame buildings

    … is characterized by the prevalent use of light wood framing. The increasing urban population and the imperative to achieve sustainability goals demand permitting taller structures in regions previously marked by low-rise building practices. Since 2009, the Building Code of British Columbia has …

    uvic Repository record for Seismic evaluation of high-capacity shear walls used in mid-rise light wood frame buildings (opens in a new tab)

  11. Analytical Modeling of Wood-Frame Shear Walls and Diaphragms

    Analytical models of wood-frame shear walls and diaphragms for use in monotonic, quasi-static (cyclic), and dynamic analyses are developed in this thesis. A new analytical model is developed to accurately represent connections between sheathing panels and wood framing members (sheathing-to-framing …

    byu Repository record for Analytical Modeling of Wood-Frame Shear Walls and Diaphragms (opens in a new tab)

  12. Analysis of Framing Failures in Wood-Frame Residential Roofs Under Wind Load

    Wood-frame residential roof failures are among the most common and expensive types of tornado damage. Hip roofs are commonly understood to be more resilient during extreme wind in relation to gable roofs. However, inspection of damage survey data from recent tornadoes has revealed a previously …

    uwo Repository record for Analysis of Framing Failures in Wood-Frame Residential Roofs Under Wind Load (opens in a new tab)

  13. Studies on Hazard Characterization for Performance-based Structural Design

    … In considering seismic hazard, a risk-consistent framework for displacement-based seismic design of engineered multistory woodframe structures was developed. Specifically, a database of probability-based scale factors which can be used in a direct displacement design (DDD) procedure for woodframe …

    tamu Repository record for Studies on Hazard Characterization for Performance-based Structural Design (opens in a new tab)