Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 268 for “"working electrode"”.
-
Electrochemical Measurement of Metal Ions in Water
… water by square wave anodic stripping on a gold working electrode. The rate constant of the anodic stripping of Pb0 from gold has a rate constant of approximately k0 = 3 s-1. A set of square wave profiles defined by step height = 1 mV, pulse height = 30 mV, and pulse width = 50, 100, 200 ms yield …
-
Field-Effect Modulation of Electrochemical Reactions on Ultrathin Semiconductor Electrodes using High-k Dielectric Layer
… charge transfer on ultrathin semiconducting electrodes for enhanced electrochemical reaction kinetics. Instead of changing the chemical composition of a semiconductor, a physical approach is adopted to modulate the solution electrochemistry on ultrathin semiconductor working electrodes by …
-
Bio-Inspired Materials for Electrochemical Sensors
… alike. Typically, these systems exist in a three-electrode conformation with a working electrode functioning as the anode, a counter electrode functioning as the cathode, and a reference electrode allowing for the control of potential in the system. The method by which these sensors work is …
-
Thin film technology for chemical sensors
… (HECL) device is an integrated microelectrode device that combines an insulator-covered working electrode and a platinum counter electrode on a single chip. Two types of fluidic systems were integrated on the same type of electrode chip: either an enclosed sample chamber made of …
-
Behavior of Different Sizes of Strontium Titanate Substrates in Electrochemical Modifications
… and that served as a connection between the STO working electrode and the potentiostat circuit. The size and density of the crystals were found to depend on electrochemical potential, its polarity, the length of modifying time, and the total electrical charge that passed during electrochemical …
-
Analysis of Electrode Geometric Parameters on AC Impedance Response
… AC impedance response. A conventional three electrode EIS method was used to perform the investigation in the present study. Saturated potassium chloride solution was used as the electrolyte, and three different material rods were used as working electrodes. Different configurations of …
-
Theoretical Modeling of Cortisol Sensor
… by Bard et al. [3]. The surface area of the working electrode of the sensor varies with and is directly proportional to the concentration of the analyte. Theoretical current peaks are hypothesized to be within 10 percent tolerance limits (mainly due to the reason that the surface area of the …
-
Fully printed potentiometric pH sensor
… Ag/AgCl with and without a graphite layer as the working electrode in a two-electrode potentiometric sensor on a flexible substrate. The role of the graphite layer on the working electrode has been investigated. PANI/G composites were prepared by a solution processing method using a graphite paste …
-
Development of miniaturized capillary electrophoresis system with electrochemical detection
… involved the microfabrication of a Au thin-film electrode and fabrication of PDMS piece with patterned channels. This system was found to be unstable and give poor performance. To improve the overall performance, several steps were taken. First, a portable and cheap power supply was developed …
-
ELECTROCHEMICAL SENSORS FOR SENSITIVE AND SPECIFIC DETECTION OF ORGANOPHOSPHATE, HEAVY METAL ION, AND NUTRIENT
… on the mass transport of the analyte towards the working electrode-electrolyte interface and working electrode properties. Carbon nanomaterials like carbon nanotubes are widely employed to modify the working electrode properties for sensitive detection. A simulation model is formulated to …
-
Photo-assisted Enhancement of Formic Acid Oxidation over Platinized TiO2 Nanotube Composite
… are formed. The composite was tested as a working electrode in the photoelectrooxidation of FA for applications such as fuel cells. Electrochemical characterization of the synthesized electrode was studied under the effect of light in order to determine the current generation of the …
-
ELECTROCHEMICAL CAPACITANCE MEASUREMENTS TO STUDY MOLECULAR SURFACE INTERACTIONS
… of biological molecules such as proteins at the electrode/electrolyte has been of considerable interest for the development of biosensors. Several investigative techniques including Potentiometry, Voltammetry, Amperometry, and Electrochemical Impedance Spectroscopy are being employed to study and …
-
Comportement éléctrochimique du C60 et du C70 en milieu aqueux
… or in water, using notably platinium ultramicroelectrode as the working electrode. The differences between the redox potentials of C60 relative to C70 indicate that it is easier to add electrons to C70 and its anions compared to the counterparts of C60. In the second part of the work, the …
-
Heat resistant polymer electrolyte for enhanced organic electrochromic windows based on poly (3,3-dimethyl-3,4-dihydro-2H-thieno[3,4-b][1,4]dioxepine)
… An ECW is composed of three components, a working electrode based on electrochromic materials, a counter electrode based on ion storage materials and the electrolyte as an ionic conducting layer. Organic ECWs have been gaining popularity due to easy and cost effective manufacturing, …
-
Toward Electrochemical Detection of Salmonella enterica Serovar Enteritidis on Hydroponically Grown Green Onions (Allium Fistulosum L.)
… of a polyimide film using a CO2 laser. The working electrode was decorated with platinum nanoparticles (nPt) via Frequency Modulated Electrodeposition (FMED) to increase performance and conductivity. Electrochemical characterization was carried out via cyclic voltammetry (CV), and …
-
Synthesis of dibenzo[a,e]cyclooctatetraene based conducting polymer : a potential molecular polymer actuator
… Polymer is first grown on a metallic working electrode and further coated on an ITO plate. UV-Vis experiment is also done. A [pi] [arrow] [pi]* transition is observed as the primary polymer electronic absorption peak. Thickness of the polymer film is also recorded.
-
Amperometric Glucose Biosensor by Means of Electrostatic Layer-by-layer Adsorption onto Electrospun Polyaniline Fibers
… biosensor was fabricated from these fibers as a working electrode, and used to measure the glucose concentration accurately.
-
Understanding substrate and inhibitor interactions with Mo-nitrogenase
… coupled to the hydrolysis of ATP, a carbon working electrode was used instead of Fe protein as a reductant to supply electrons to MoFe protein. A series of known inhibitors and different possible substrates of nitrogenase (including protons, dinitrogen, acetylene, isocyanides and carbon …
-
Fabrication of μ-pH Biosensor for Implantable Medical Devices and Applications in Detecting Post-Operative Complications
… work, a pH sensor is presented consisting of a working electrode, a counter electrode and reference Ag/AgCl fabricated to allow the signals to be collected and compared to a reference value. For the working electrode, we chose Polyaniline (PANI) as the sensing material. Upon exposure to …
-
The Influence of Bipolar Electrochemical Cell Geometry on the Studies of Pitting Corrosion
… including studying localized corrosion, gradient electrodeposition, propulsion of micromotors, and water treatment. The popularity of the method is not solely dependent on its wirelessness but more due to the simultaneous presence of cathodic and anodic poles on the same surface, which also begets …