Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"x ray unit"”.

  1. Design and construction of a 50 kilovolt x-ray unit

    Thesis (M.S.)--Michigan State College of Agriculture and Applied Science,

    msu Repository record for Design and construction of a 50 kilovolt x-ray unit (opens in a new tab)

  2. Calibration of an X-Ray Unit as to Effective Wave-Lengths by Comparing Absorption Coefficients

    … and iron, the effective wave-length of an X-ray beam which passes through particular thicknesses of the above materials. Since an X-ray tube does not emit a monochromatic wavelength but emits heterogeneous wave-lengths, we had to use a comparative method in order to obtain the desired …

    marquette Repository record for Calibration of an X-Ray Unit as to Effective Wave-Lengths by Comparing Absorption Coefficients (opens in a new tab)

  3. A Method to Determine Curved Surface laminagraphic width and position in Panoral Radiography Utilizing the Panorex X-ray Unit

    Although the Panorex X-ray unit has been in existence for almost a decade, no information is publicly available relative to the determination of its laminagraphic slice width or position. In order to utilize the machine most effectively as a research tool, it seems imperative that this width and …

    loma-linda Repository record for A Method to Determine Curved Surface laminagraphic width and position in Panoral Radiography Utilizing the Panorex X-ray Unit (opens in a new tab)

  4. Volume Changes Accompanying the Melt-Crystal Transition in Binary Borate Melts

    … volumes of the crystals were calculated using x-ray unit cell densities and volume thermal expansion coefficients obtained by high-temperature x-ray diffraction analysis. Melt specific volumes had been previously determined.

    uiuc Repository record for Volume Changes Accompanying the Melt-Crystal Transition in Binary Borate Melts (opens in a new tab)

  5. A Transcranial Radiographic Examination of the Temporal Portion of the Temporomandibular Joint

    … ordinary dental office has a standard dental X-ray machine and, perhaps, a panoramic X-ray unit. To image the human temporomandibular joint, the dentist will often refer a patient to a facility with more sophisticated imaging machines. Already in 1933, however, Lindblom recognized that with …

    marquette Repository record for A Transcranial Radiographic Examination of the Temporal Portion of the Temporomandibular Joint (opens in a new tab)

  6. Photodynamische Therapie mit Tetrahydroporphyrin-Tetratosylat (THPTS) und ihre Kombination mit ionisierender Strahlung in humanen Glioblastomzellen

    … survival were assessed. IR was conducted on an X-ray unit (0.813 Gy/min). Results were verified in vivo on a subcutaneous C6 glioblastoma model in Wistar rats. Conclusions: This study demonstrated efficient THPTS-PDT in glioblastoma cells, in vitro and in vivo. The combinatorial effects of …

    qucosa-diss

  7. Patient Specific Radiation Doses From Projection Radiography Images: Improving the Accuracy of Low Dose Radiation Calculations

    … acquired during routine physics testing of the x-ray unit, data from two-view (Anterior-Posterior and Lateral chest) radiographic images, and accounts for patient specific and body habitus. The algorithm developed in this work uses formulas for calculating entrance and exit dose utilizing a new …

    unm Repository record for Patient Specific Radiation Doses From Projection Radiography Images: Improving the Accuracy of Low Dose Radiation Calculations (opens in a new tab)

  8. Axially accelerated saboted rods subjected to lateral forces.

    … loading on the sabot/rod system. A 2.3-MeV x-ray unit was used to determine the lateral displacement that occurred as the sabot/rod was forced through the bent tube. After the sabot/rod exited the launch tube, the sabot separation and rod straightness were recorded by four 150-keV x-ray units. …

    arizona-thes Repository record for Axially accelerated saboted rods subjected to lateral forces. (opens in a new tab)

  9. Methodology development for breast cancer diagnosis using dual energy x-rays and digital tomosynthesis

    Breast cancer screening and diagnosis in X-ray mammography rely on the detection and visualization of microcalcifications (μCs) and masses. The detection and visualization of μCs are relatively easy over a uniform tissue background. However, visualization of μCs could be obscured in mammograms by …

    greece Repository record for Methodology development for breast cancer diagnosis using dual energy x-rays and digital tomosynthesis (opens in a new tab)

  10. Measurements of Continuous X-Ray Spectra with a Scintillation Spectrometer

    … spectrometer measurements were made of the x-ray spectra produced by a constant-potential x-ray unit operating at 100, 150, 200, 250, and 300 kV. An attempt was made to measure the absolute intensity as well as the spectral distribution. In order to reduce the counting rate to a measureable …

    unm Repository record for Measurements of Continuous X-Ray Spectra with a Scintillation Spectrometer (opens in a new tab)

  11. Design mobilního rentgenu

    Diplomová práce se zabývá vytvořením designu mobilního nemocničního rentgenu. Na základě provedených analýz jsou navženy tři variantní studie designu, ze kterých je následně vybrána a detailně rozpracována finální varianta. Při návrhu jsou zohledňovány ergonomické a technické požadavky s cílem …

    brno-tech Repository record for Design mobilního rentgenu (opens in a new tab)

  12. Some factors affecting the immune response to helminth infections

    … contortus larvae lambs failed to express any immunity to subsequent challenge with normal larvae. Unfortunately this aim was not achieved due to the fact that the H. contortus irradiated larval vaccine failed to confer protection to subsequent challenge. This result was totally unexpected as in …

    glasgow Download PDF for Some factors affecting the immune response to helminth infections (opens in a new tab)

  13. The Two-Year Mass Radiography Campaign in Scotland, 1957-1958: A Study of Tuberculosis Case-Finding by Community Action

    … execution and results of a programme of chest X-ray surveys carried out in 22 areas of high tuberculosis prevalence in Scotland during 1957 and 1958, with the object of finding and bringing under control a high proportion of the previously undisclosed reservoir of cases, reducing the pool of …

    glasgow Download PDF for The Two-Year Mass Radiography Campaign in Scotland, 1957-1958: A Study of Tuberculosis Case-Finding by Community Action (opens in a new tab)

  14. Konstrukční návrh tříosého manipulátoru

    Cílem diplomové práce je konstrukční návrh tříosého manipulátoru sloužícího jako zubní rentgen. Osy se skládají z rotačního a dvou translačních pohybů. Práce vychází z již sestaveného manipulátor a cílem je snížení vertikálního zástavbového prostoru, snížení hmotnosti, zvýšení přesnosti a …

    brno-tech Repository record for Konstrukční návrh tříosého manipulátoru (opens in a new tab)

  15. Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy

    … of a semiconductor layer divided into an array of pixels. This array of pixels is bumpbonded to an electronics integrated layer (i.e. the readout chip). Timepix can be used for a wide range of measurements of electromagnetic radiation and particles and their applications in different fields …

    adelaide Repository record for Investigation of timepix radiation detector for autoradiography and microdosimetry in targeted alpha therapy (opens in a new tab)