Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 54 for “"zemax"”.

  1. Feasibility of focusing optics for the use of RELIEF in engine test facilities

    … lens system designs were obtained using the Zemax<sup>TM</sup> optical design program. This program provides a platform to simulate the representative duct sizes in the engine test facilities at AEDC and to design scaled optics for each. Though Zemax<sup>TM</sup> offers the capability to …

    ut-knoxville Repository record for Feasibility of focusing optics for the use of RELIEF in engine test facilities (opens in a new tab)

  2. Confocal acoustic holography for non-invasive 3D temperature and composition measurement

    … components and ray tracing simulations using Zemax optical design software. Simulated acoustic holograms and fringe shifts were produced and they were found to match up very well with theoretical calculations. A simplified acoustic holography instrument was built and tested. Speed of sound …

    uvic Repository record for Confocal acoustic holography for non-invasive 3D temperature and composition measurement (opens in a new tab)

  3. Návrh slunečního koronografu pro CubeSat

    … vyhodnocení navrženého systému v prostředí Ansys Zemax OpticStudio. Součástí práce je také vyhodnocení optické výkonnosti návrhu, jeho citlivosti na výrobní a justážní tolerance, vlivu teplotních změn a možnosti využití komerčně dostupných optických prvků.

    brno-tech Repository record for Návrh slunečního koronografu pro CubeSat (opens in a new tab)

  4. Optický návrh telecentrického f-theta objektivu

    … byl vytvořen optimalizaci pomocí programu ZEMAX OpticsStudio.

    brno-tech Repository record for Optický návrh telecentrického f-theta objektivu (opens in a new tab)

  5. Komponenty pro laserovou mikromanipulaci v koherencí řízeném digitálním holografickém mikroskopu

    … Brne. Bola spravená ich optimalizácia v programe ZEMAX. Pre vybraný návrh bol vytvorený 3D model v programe Autodesk Inventor PROFESSIONAL 2010.

    brno-tech Repository record for Komponenty pro laserovou mikromanipulaci v koherencí řízeném digitálním holografickém mikroskopu (opens in a new tab)

  6. Properties Of High Energy Laser Light Transmission Through Large Core Optical Cables

    … of failure. iv Models using R-Soft BeamProp and Zemax were developed to study transmission losses, investigate light interactions at critical areas, and predict under which conditions laser damage would occur. BeamProp presents a clearer view of the modal distribution of light within the core of …

    ucf Repository record for Properties Of High Energy Laser Light Transmission Through Large Core Optical Cables (opens in a new tab)

  7. Light Pipe Design for Solar Concentrator

    … All of the simulations are accomplished by Zemax, TracePro, and Matlab. Each of this three software has their own advantages, for example, Zemax is handy to trace rays as several different conditions, TracePro has many professional built-in tools (e.g., Solar simulator), and Matlab allows …

    tamu Repository record for Light Pipe Design for Solar Concentrator (opens in a new tab)

  8. The Sine Condition Test Plus: Development of a Novel Alignment Method using Deflectometry and the Sine Condition Test

    … the theory by comparing the prediction of the Zemax model and the measured data with the SCT+ and to check the performance of the SCT+ with the verified interferometric method. The state of alignment measured with the SCT+ matched the Zemax prediction and interferometer within the expected …

    arizona-thes Repository record for The Sine Condition Test Plus: Development of a Novel Alignment Method using Deflectometry and the Sine Condition Test (opens in a new tab)

  9. Výroba polymerních optických prvků a jejich analýza elektronovou mikroskopií

    … K návrhu byl použit software pro optické návrhy ZEMAX OpticStudio ver. 21. Výroba proběhla kombinací metod dvoufotonové polymerace a nanoimprintové litografie. Kvalita povrchu, profilu a kontrola vad byla provedena na konfokálním mikroskopu a na rastrovacím elektronovém mikroskopu. Funkce …

    brno-tech Repository record for Výroba polymerních optických prvků a jejich analýza elektronovou mikroskopií (opens in a new tab)

  10. Kombinovaný mikroskop pro mikroskopii živé buňky

    … ověřena pomocí simulací v softwarovém prostředí Zemax OpticStudio. Mikroskop integruje kromě standardních metod světelné mikroskopie také vícekanálovou konfokální mikroskopii. Optické uspořádání využívá komponenty z původního fluorescenčního holografického mikroskopu a nově navržené konstrukční …

    brno-tech Repository record for Kombinovaný mikroskop pro mikroskopii živé buňky (opens in a new tab)

  11. Miniature objective lens design for multiphoton microscopy

    … at the limit of their depth-scanning range. Zemax software is used to evaluate aspherical lenses for use as objectives, to evaluate the effect of scanning optics, and to design a custom water-dipping objective. Simulations show that the custom objective is capable of achieving …

    ubc Repository record for Miniature objective lens design for multiphoton microscopy (opens in a new tab) Download PDF for Miniature objective lens design for multiphoton microscopy (opens in a new tab)

  12. Návrh osvětlovacího modulu pro CCHM mikroskop

    … vybrány vhodné optické komponenty a v softwaru Zemax provedeny simulace k ověření, že jsou všechny stanovené požadavky splněny. Při konstrukci je dbáno na kompaktnost a kompatibilitu sestavy. Proto je k osvětlení amplitudového modulátoru světla použit hranol s totálním vnitřním odrazem. Dále …

    brno-tech Repository record for Návrh osvětlovacího modulu pro CCHM mikroskop (opens in a new tab)

  13. Meta-form near eye visor

    … visor’s vision performance is simulated in Zemax. Image simulation using the designed metasurface is performed in Lumerical FDTD. In this design dielectric material is chosen to compose the metasurface, for its lower loss in visible frequency than metallic metasurface.

    washington Repository record for Meta-form near eye visor (opens in a new tab)

  14. Design and Development of Compact Multiphoton Microscopes

    … investigated using the optical design software: Zemax. A novel characterization methodology based on 'nonlinear knife-edge' technique was also introduced to measure the axial, lateral resolution, and the field curvature of the multi-photon microscope's image plane. The field curvature was then …

    arizona-thes Repository record for Design and Development of Compact Multiphoton Microscopes (opens in a new tab)

  15. OPTIMIZATION OF MICRO-LENS ON LED CHIP

    … has been carried out on size. So software ZEMAX is used in ray tracing to optimize the position and shape of the microlens and a better coupling between fiber and lens is obtained. For three different packaging, the limiting factors of low efficiency are analyzed, and new shapes and …

    nus Repository record for OPTIMIZATION OF MICRO-LENS ON LED CHIP (opens in a new tab) Download file for OPTIMIZATION OF MICRO-LENS ON LED CHIP (opens in a new tab)

  16. Numerical modeling and ray tracing of SPatIal Frequency modulation for Imaging

    … The ray tracing analysis is performed using the ZEMAX software for configurations involving achromatic lenses, flat field lenses, and a specialized lens array setup. Lastly, a unique SPIFI design setup is presented making use of a reflective scanned SPIFI mask to achieve random access imaging using …

    colo-mines Repository record for Numerical modeling and ray tracing of SPatIal Frequency modulation for Imaging (opens in a new tab)

  17. Korelativní metody pro mikroskopii živé buňky

    … do systému hiQPI. Optické simulace v prostředí Zemax byly využity k optimalizaci vzdálenosti tubusové čočky od vzorku, aby se předešlo ořezu svazku. Součástí práce je také detailní mechanický návrh v prostředí SolidWorks, který zahrnuje návrh jemných seřizovacích mechanismů kompatibilních jak s …

    brno-tech Repository record for Korelativní metody pro mikroskopii živé buňky (opens in a new tab)

  18. Exploration of Semiconductor Gain Medium, Resonator, Pump, and Frequency Stabilization for Laser Guide Star Applications

    … Multi-pass pumping schemes were designed with Zemax modeling and demonstrated experimentally. To simplify multi-pass pumping, the hybrid-MECSEL (H-MECSEL) design was introduced. COMSOL modeling studied thermal management and thermal lensing effect. The H-MECSEL achieved approximately 30 W of …

    unm Repository record for Exploration of Semiconductor Gain Medium, Resonator, Pump, and Frequency Stabilization for Laser Guide Star Applications (opens in a new tab)

  19. Waveftont Error Reduction For Large Segmented Mirror Space Telescopes

    … mirror support geometries are presented. Zemax Opticstudio simulation software has been implemented to construct and analyze an optical model based off the JWST. It has been found that support struts have a much larger impact on the image performance than compared to the mirror …

    jhu Repository record for Waveftont Error Reduction For Large Segmented Mirror Space Telescopes (opens in a new tab)

  20. Chromatic Aberration Correction for Improved Stimulated Raman Signal

    … commercial lens configurations was conducted in Zemax OpticStudio, using chromatic focal shift and lateral color as optimization targets. A Plössl eyepiece consisting of two Newport Scientific PAC12AR.16 100 mm achromatic doublets was identified as the strongest candidate for lateral color …

    washington Repository record for Chromatic Aberration Correction for Improved Stimulated Raman Signal (opens in a new tab)

Page 1 of 3