Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"zernike coefficients"”.

  1. Clustering Analysis of Zernike Coefficients Through Quantile Regression

    … clustering procedure to cluster fifteen Zernike coefficients into groups. Quantile regressions are considered to describe the relationship between Zernike coefficients and pupil size. We employ Gibbs sampler and adaptive rejection Metropolis sampling to infer the parameters for each …

    south-carolina Repository record for Clustering Analysis of Zernike Coefficients Through Quantile Regression (opens in a new tab)

  2. Clustering Analysis of Zernike Coefficients From High Order Aberration Patients

    This thesis focuses on clustering fifteen Zernike coefficients using the method of clustering of linear regression models (CLM). EM algorithm is used to infer the maximum likelihood estimate of parameters for each cluster. Bayesian information criterion (BIC) combined with Bootstrapped maximum …

    south-carolina Repository record for Clustering Analysis of Zernike Coefficients From High Order Aberration Patients (opens in a new tab)

  3. Use of annular subapertures with focus control for testing rotationally symmetric optical systems.

    … involving annular subapertures, such as annular Zernike polynomials, are provided in detail. Numerical and experimental validations of the algorithm are described. Tolerance analyses on subaperture measurements are given. Computer programs were written to link the subaperture Zernike coefficients …

    arizona-thes Repository record for Use of annular subapertures with focus control for testing rotationally symmetric optical systems. (opens in a new tab)

  4. OPTICAL TESTING OF LARGE TELESCOPES USING MULTIPLE SUBAPERTURES

    … review is given of two algorithms utilizing Zernike polynomials. A third subaperture testing analysis algorithm, the Stuhlinger method, is developed in this work; this provides raw phase data over the entire aperture of the system under test. A statistical analysis of this algorithm is given. …

    arizona-thes Repository record for OPTICAL TESTING OF LARGE TELESCOPES USING MULTIPLE SUBAPERTURES (opens in a new tab)

  5. Pinças ópticas: compensação de aberrações ópticas via modulação espacial de luz

    … a spatial light modulator, applying first-order Zernike coefficients for the following aberrations: spherical aberration, astigmatism, coma, and trefoil. A theoretical model for optical traps in the Mie scattering regime, including spherical aberration introduced by a glass–water interface, was …

    brazil-uerj Repository record for Pinças ópticas: compensação de aberrações ópticas via modulação espacial de luz (opens in a new tab)

  6. Assessment of ocular aberrations at scaled pupil size and reduced Shack-Hartmann spot number

    … aberration is generally described in terms of Zernike polynomials. However, the Zernike polynomials are pupil size dependent, therefore, the aberration measured at a fixed pupil size cannot be used for another pupil size. One solution to this problem is to use pupil size scaling technique to …

    waterloo Repository record for Assessment of ocular aberrations at scaled pupil size and reduced Shack-Hartmann spot number (opens in a new tab)

  7. Statistical wavefront model of accommodation: analysis and synthesis

    … males and females. A database of wavefront Zernike coefficients for different levels of accommodation was created to develop a statistical model to generate synthetic random samples. Once the database was completed, the model was developed, applying Principal Component Analysis as a …

    minho-thes Repository record for Statistical wavefront model of accommodation: analysis and synthesis (opens in a new tab) Embargoed until 2027-02-05

  8. Novel Methods in Computational Imaging with Applications in Remote Sensing

    … estimate of the image is obtained along with the Zernike coefficients associated with the atmospheric PSF at each frame, and the Fried parameter r0 of the atmosphere. A pair of constraints are applied to a penalized least squares objective function to enforce the theoretical statistics of the set …

    mtu Repository record for Novel Methods in Computational Imaging with Applications in Remote Sensing (opens in a new tab)

  9. Coherence Gated Laser Ray Tracing Based on a High Speed FPGA Platform

    … sensor. Results are shown, in the form of Zernike modes, which demonstrate the ability of the instrument to resolve wavefronts from a multi-layer target (two stacked microscope slides and a mirror). Also, an FPGA based embedded system was developed for all command, control, image processing …

    kent Download PDF for Coherence Gated Laser Ray Tracing Based on a High Speed FPGA Platform (opens in a new tab)

  10. Adaptive optics aberrometer and wavefront corrector using a twisted-nematic liquid-crystal on silicon chip

    … that were carried out include the generation of Zernike wavefronts, measurements of Zernike coefficients of elements with known and unknown optical properties, as well as open- and closed-loop corrections of static and dynamic aberrations. Parameters such as experimental and simulated point …

    edithcowan Repository record for Adaptive optics aberrometer and wavefront corrector using a twisted-nematic liquid-crystal on silicon chip (opens in a new tab)

  11. Statistical Analysis of Hartmann-Shack Images of a Pre-school Population

    … were calibrated in order to determine the Zernike coefficients up to the 8th order for a pupil diameter of 5mm. The MATLAB code proposed by Thibos et al that follows the standard for reporting the optical aberrations of the eye was the basis of code written for this study. Modification was …

    waterloo Repository record for Statistical Analysis of Hartmann-Shack Images of a Pre-school Population (opens in a new tab)

  12. Retinal Imaging with Computational Adaptive Optics and Non-sinusoidal Structured Illumination

    … analysis of phase aberrations in terms of the Zernike coefficients is conducted to show variation in aberrations in different depth layers and regions of the retina. Additionally, images with structured fringes containing spatially varying entropy are assessed using this method. The analysis …

    unsw Repository record for Retinal Imaging with Computational Adaptive Optics and Non-sinusoidal Structured Illumination (opens in a new tab) Embargoed

  13. Repeatability and Validity of the Discovery System

    … Instrument order was randomized at each visit. Zernike coefficients were calculated over a 6-mm pupil through the sixth radial order. Between-instrument agreement was assessed using difference versus mean plots and the 95% LoA. Results: The mean age (±SD) and spherical equivalent refractive …

    houston Repository record for Repeatability and Validity of the Discovery System (opens in a new tab)

  14. Vergleich der kornealen und okulären Aberrationen mittels kornealer Topographie und Wellenfront-Aberrometrie

    … Es wurden die kornealen und okulären Zernike-Koeffizienten der 2. bis 4. Ordnung sowie die RMS-Fehler ermittelt. Ergebnisse: Die optischen Abbildungsfehler höherer Ordnungen waren kleiner als 0,2µm. Die kornealen Aberrationen waren dabei größer als die okulären Wellenfrontfehler. Je …

    fu-berlin Repository record for Vergleich der kornealen und okulären Aberrationen mittels kornealer Topographie und Wellenfront-Aberrometrie (opens in a new tab)

  15. The International Liquid Mirror Telescope: optical testing and alignment using a Nijboer-Zernike aberration retrieval approach

    … a new approach, based onthe theory of Nijboer-Zernike (NZ), is very promising. This technique is thus developed and adapted inorder to be appropriate for our particular needs (related to the ILMT). Using numerical simulations, westudy this method and its limitations. The aberrations are …

    liege Repository record for The International Liquid Mirror Telescope: optical testing and alignment using a Nijboer-Zernike aberration retrieval approach (opens in a new tab) Download PDF for The International Liquid Mirror Telescope: optical testing and alignment using a Nijboer-Zernike aberration retrieval approach (opens in a new tab)