Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 17 of 17 for “"zero sequence current"”.

  1. The Application of Model Predictive Control on Paralleled Converters for Zero Sequence Current Suppression and Active Thermal Management

    … can arise, including voltage fluctuations, zero sequence circulating current, and thermal imbalance. Achieving stable DC bus voltage is essential for maintaining the proper functioning of electronic devices, while suppressing zero sequence current is necessary for protecting the power …

    clemson Repository record for The Application of Model Predictive Control on Paralleled Converters for Zero Sequence Current Suppression and Active Thermal Management (opens in a new tab)

  2. INVESTIGATION OF TORQUE PRODUCTION AND CONTROL STRATEGY FOR VARIABLE FLUX RELUCTANCE MACHINES

    … which reveals the contributions of harmonic currents and inductances to the torque production. By using Fourier series, all of the harmonics in the phase currents and winding inductances are considered. It was found that the average torque of a 6/4 VFRM is mainly produced by the dc, …

    whiterose Download PDF for INVESTIGATION OF TORQUE PRODUCTION AND CONTROL STRATEGY FOR VARIABLE FLUX RELUCTANCE MACHINES (opens in a new tab)

  3. Directional Sub-Cycle Fault Detection On Systems Containing Inverter-Based Resources

    … are much different than the short circuit current that is generated from traditional sources. This different response to faults may cause traditional protection schemes to fail in detecting when a fault is present, thus leading the demand to find new ways to maintain proper protection of …

    sask Repository record for Directional Sub-Cycle Fault Detection On Systems Containing Inverter-Based Resources (opens in a new tab) Embargoed until 2027-12-18

  4. Fault-Tolerant Strategies for Multiphase Open-End Winding Permanent Magnet Synchronous Machine Drive System

    … locations. The proposed strategy utilizes zero-sequence current to offset the phase current such that a unipolar phase current is obtained within faulty phases. Post-fault operation under open-circuit diode (and IGBT) failure are demonstrated with a capability of generating 70.4% of rated …

    unsw Repository record for Fault-Tolerant Strategies for Multiphase Open-End Winding Permanent Magnet Synchronous Machine Drive System (opens in a new tab)

  5. Control Strategies for Dual Inverter-fed Open-end Winding PM machines with Nonsinusoidal back EMFs

    … to one dc source. However, considering the zero sequence voltage is clamped to zero because of the return path between the two inverters, zero sequence current circulates in the machine windings which increases losses and generates heat. Furthermore, most PMSMs generate harmonics in the back …

    unsw Repository record for Control Strategies for Dual Inverter-fed Open-end Winding PM machines with Nonsinusoidal back EMFs (opens in a new tab)

  6. Developing A Medium-Voltage Three-Phase Current Compensator Using Modular Switching Positions

    … and testing of a proposed solution to unbalanced current loading on three-phase four-wire systems. This solution, known as the Medium-Voltage Unbalanced Current Static Compensator or MV-UCSC, is designed to recirculate currents between the three phases of adistribution system. Through this …

    arkansas Repository record for Developing A Medium-Voltage Three-Phase Current Compensator Using Modular Switching Positions (opens in a new tab)

  7. Asymmetrical operation of EHV transmission lines

    … on electromagnetic modelling, converter-based sequence-current mitigation, and safety-related voltage assessment. First, a high-fidelity three-phase simulation model of a long overhead power transmission line is developed. The model explicitly represents electromagnetic coupling between …

    strathclyde Repository record for Asymmetrical operation of EHV transmission lines (opens in a new tab)

  8. Small signal impedance modelling and stability assessment of HVDC systems

    … is mapped into the positive-negative (pn) sequence-frame for ease of analysis, and the stability problem associated with the coupling admittance is studied. It is found that traditional outer-loop controllers (e.g., active/reactive power and AC voltage controllers) create high coupling …

    strathclyde Repository record for Small signal impedance modelling and stability assessment of HVDC systems (opens in a new tab)

  9. Adaptive digital distance protection

    … the characteristics according to the postfault zero sequence current. It is shown that the resistive to reactive reach ratio of the relay may be set to 3 without gross overreaching of the relay or particular reference to the line application. The relay incorporates a novel power swing blocking …

    city-london Download PDF for Adaptive digital distance protection (opens in a new tab)

  10. The location of flashovers on Transmission lines

    … is eliminated. The pulse generator is tripped by zero-sequence current or from the surge created by the fault itself. The pulses were to be recorded on a skiatron or memory tube which holds the trace on the tube until it is erased at will by the operator. This eliminates the necessity of …

    ubc Repository record for The location of flashovers on Transmission lines (opens in a new tab) Download PDF for The location of flashovers on Transmission lines (opens in a new tab)

  11. Analysis and Design of New Harmonic Mitigation Approaches

    … proposed in order to resolve the problems of current harmonics in electrical distribution systems. The rapid development of power semiconductors along with the revolutionary advances on microprocessors consolidated the motor drives industry and with it a massive proliferation of non-linear …

    tamu Repository record for Analysis and Design of New Harmonic Mitigation Approaches (opens in a new tab)

  12. Next-generation, phasor-based distance relay with fault-path resistance immunity

    … relay. In other words, it requires voltage and current information from only one end of the transmission line that it protects. Another advantage is that knowledge of the system equivalent source impedance is not required. While knowledge of the distribution factor phase angle, parallel line …

    vt Repository record for Next-generation, phasor-based distance relay with fault-path resistance immunity (opens in a new tab)

  13. Differential Protection for Arbitrary Three-Phase Power Transformers

    … thesis describes how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use …

    lund Repository record for Differential Protection for Arbitrary Three-Phase Power Transformers (opens in a new tab) Download PDF for Differential Protection for Arbitrary Three-Phase Power Transformers (opens in a new tab)

  14. Open-Winding Permanent Magnet Synchronous Machines Under Demagnetization Faults

    … common DC bus topology is the natural flow of zero-sequence currents (ZSC) through the stator windings. Under healthy conditions, ZSC is primarily dominated by the third harmonic component, originating from inverter-induced zero-sequence voltage and machine back-EMF harmonics. This leads to …

    unsw Repository record for Open-Winding Permanent Magnet Synchronous Machines Under Demagnetization Faults (opens in a new tab)

  15. Modular multilevel matrix converter for fractional frequency transmission in offshore wind power integration

    … from the disadvantage of high charging reactive current and therefore the maximum transmission distance is very limited. Fractional frequency transmission (FFT) is proposed to overcome this difficulty. With the offshore side operating at one third of the onshore grid frequency, the reactive …

    birmingham Download PDF for Modular multilevel matrix converter for fractional frequency transmission in offshore wind power integration (opens in a new tab)

  16. Indikace zemních spojení na venkovních vedeních

    Tato diplomová práce se zabývá indikací a lokalizací zemních spojení na venkovních vedeních. Zemní spojení je nejčastěji se vyskytující typ poruchy na venkovních vedeních vysokého napětí – tvoří zhruba 95% všech poruch a je problematické jej současnými metodami správně a včas indikovat, …

    brno-tech Repository record for Indikace zemních spojení na venkovních vedeních (opens in a new tab)

  17. Modeling and Control of Parallel Three-Phase PWM Converters

    … voltage source inverters, buck rectifiers and current source inverters. The averaging of the parallel converters is performed based on a generic functional switching unit, which is called a phase leg in boost rectifiers and voltage source inverters, and a rail arm in buck rectifiers and current …

    vt Repository record for Modeling and Control of Parallel Three-Phase PWM Converters (opens in a new tab)